ResMed AirSense 10 Series Oximeter Adapter User Guide

June 12, 2024
ResMed

**ResMed AirSense 10 Series Oximeter Adapter User Guide

Oximeter Adapter
**

Intended use
The oximeter adapter connects a NONIN Xpod™ oximeter to your device. Oximetry data (oxygen saturation and pulse rate) is recorded on the SD card inserted into the device.

The Air10 oximeter adapter shown in illustration A is compatible with AirSense™ 10 / AirCurve™ 10 / Lumis™ devices. The oximeter adapter shown in illustration B is compatible with S9 devices. The oximeter adapter is intended for home and hospital use. Read the entire guide before using the oximeter adapter.

Air10 oximeter adapter

Refer to illustration A
Oximeter Adapter

  1.  Adapter connector
  2. Release button
  3. Oximeter port.

S9 oximeter adapter
Refer to illustration B:
Oximeter Adapter

  1. Oximeter port
  2. Release buttons
  3. Adapter clip
  4. Adapter connector.

AirSense 10 / AirCurve 10

Lumis
Refer to illustration C
Lumis

  1. SD Card cover
  2. Air filter cover
  3.  Adapter cover
  4.  Adapter port

Refer to illustration D
Product Overview

  1. DC power inlet
  2. Adapter clip socket
  3. Adapter port
  4. SD card slot
  5. Alarm (Bilevel alarmed devices only).

Associated accessories

  • Xpod oximeter
  • Xpod fixation clip
  • Finger pulse sensor
  • Oximetry accessories pack (including Xpod oximeter, Xpod fixation clip and 3M oximeter soft sensor reusable).

Note: The compatible finger pulse oximeters are calibrated for the display of functional oxygen saturation

Save the packaging
Keep all the packaging the oximeter adapter came in. You will need to return the oximeter adapter, this User Guide and the SD card to your care provider.
Setup
Refer to illustration E or F:

  1. Unplug your device from the power outlet.

  2. Make sure an SD card is inserted into the SD card slot on your device.

  3. Connect the oximeter adapter to your device.

  4. Align the Xpod oximeter connector with the oximeter adapter port and connect them.
    Not pictured:

  5. Connect the Xpod oximeter to the finger pulse sensor. instructions refer to the User Guide supplied with the finger pulse sensor.

  6. Connect the finger pulse sensor to your finger.

  7. Plug your device back into the power outlet. The AirSense 10 / AirCurve 10 / Lumis device will briefly display the oximeter software code, eg, SX123-4567.
    The S9 device will briefly display Oximeter enabled.

You are now ready to start therapy. For more information, refer to your device User Guide.

Removing and returning the oximeter adapter and
SD card

  1. Remove the sensor from your finger.
  2. Unplug your device from the power outlet.
  3. Press the release button/s on the side of the oximeter adapter and pull gently to remove it from the device.
  4. Pull the Xpod oximeter out of the oximeter port on the oximeter adapter.
  5. Remove the finger sensor cable from the Xpod oximeter.
  6. Open the SD card cover and push in the SD card to release it.
  7. Place the SD card in the protective folder and send it back to your care provider together with the oximeter adapter and this User Guide.

Cleaning and maintenance
If you need to, wipe the outside of the oximeter adapter with a clean, dry cloth. For instructions on how to clean the oximeter and its sensor, refer to the User Guide supplied with those accessories.

Troubleshooting

If you have any problems, refer to the following troubleshooting topics. If you are not able to fix the problem, contact your care provider or refer to www.resmed.com. Do not try to open the oximeter adapter.

Problem/possible cause Solution
AirSense 10 / AirCurve 10 / Lumis without oximetry  Check your finger sensor

or press OK to continue
S9:| Check the oxi sensor or press dial to accept no oximetry data logging
The finger pulse sensor is not attached to your finger| Make sure the finger pulse sensor is properly attached according to the instructions supplied with that accessory
The sensor cable is not connected to the Xpod oximeter at the start of therapy| Disconnect and reconnect the Xpod oximeter connector and sensor cable according to the instructions supplied with these accessories.
AirSense 10 / AirCurve 10 / Lumis without oximetry| Check oximeter connection or press OK to continue
S9| Connect the oxi sensor or press dial to accept no oximetry data logging
The oximeter adapter is not connected properly or data is not transmitting correctly| Remove your oximeter adapter from the device according to the instructions. Reattach your oximeter adapter and plug your device back into the power outlet.
S9| Insert your SD Card or press dial to accept no oximetry data logging
The device cannot detect an SD card and no oximetry data can be logged or stored| Make sure that an SD card is correctly inserted in the SD card slot of your device

Note: If you need help or to report an unexpected issue, contact a ResMed representative, ResMed Technical services or see www.resmed.com.

Technical specifications

Operating temperature +41°F to +95°F (+5°C to +35°C)
Operating humidity 10 to 95% non-condensing
Operating altitude Refer to your device User Guide for detaills
Storage and transport temperature -4°F to 140°F (-20°C to +60°C)

Storage and transport humidity
Air10 oximeter adapter| 5 to 95% non-condensing
S9 oximeter adapter| 10 to 95% non-condensing
Design life
Air10 oximeter adapter| 1825 connections
S9 oximeter adapter| 1825 connections
Gross dimensions
Air10 oximeter adapter| 2.1″ x 1.2″ x 2.0″
(W x D x H)| (54 mm x 30 mm x 51 mm)
S9 oximeter adapter| 1.74″ x 2.12″ x 0.91″
(L x W x H)| (44.35 mm x 54.10 mm x 23.30 mm)
Weight
Air10 oximeter adapter| 0.95 oz (27 g)
S9 oximeter adapte| 0.77 oz (22.1 g)
Oximeter compatibility
Air10 oximeter adapter| XPod 3012, XPod 3012LP
S9 oximeter adapter| Xpod 3012
Electromagnetic compatibility| Refer to your device User Guide for details.

Note: The manufacturer reserves the right to change these specifications without notice

SymbolsThe following symbols may appear on the oximeter adapter or packaging: Caution Warning.   Read instructions before use. Manufacturer. European Authorized Representative. Batch code. Catalog number. Serial number. IP21 Protection against insertion of fingers and against vertically dripping water. IP22 Protected against finger sized objects and against dripping water when tilted up to 15 degrees from specified orientation.

Humidity limitation. Temperature limitation.  China pollution control logo. Type BF equipment. Prescription only (In the US, Federal law restricts these devices to sale by or on the order of a physician). Atmospheric pressure limitation. Importer. Medical device

See symbols glossary at ResMed.com/symbols.

Notes:

  • IP21 rating applies only to S9 oximeter adapter.
  • IP22 rating applies only to Air10 oximeter adapter

Environmental information
This device should be disposed of separately, not as unsorted municipal waste. To dispose of your device, you should use appropriate collection, reuse and recycling systems available in your region. The use of these collection, reuse and recycling systems is designed to reduce pressure on natural resources and prevent hazardous substances from damaging the environment. If you need information on these disposal systems, please contact your local waste administration. The crossed-bin symbol invites you to use these disposal systems. If you require information on collection and disposal of your ResMed device please contact your ResMed office, local distributor or go to www.resmed.com/environment.

WARNING

  • Do not open or modify the oximeter adapter. The oximeter adapter is not designed to be serviced. There are no serviceable parts inside.
  • Only use compatible NONIN™ finger pulse oximeters*.
  • The finger pulse oximeter and cable needs to be verified for compatibility with AirSense 10 / AirCurve 10 / Lumis devices, otherwise, patient injury can result.
  • Finger pulse oximeters must not be used with excessive pressure for prolonged periods as this can cause patient pressure injury.
  • The reported values from the finger pulse oximeter are not appropriate to be used for diagnostic purposes and it shall not be used for vital sign monitoring.

For part numbers of compatible oximeter accessories, refer to www.resmed.com or contact your care provider. For information on how to use these accessories, refer to the user guide that comes with these accessories.

CAUTION

  • In the US, Federal law restricts this device to sale by or on the order of a physician.
  • Only use the oximeter adapter as specified in this guide.
  • S9 oximeter adapters are specifically designed for use with ResMed S9 devices.
  • Air10 oximeter adapters are specifically designed for use with ResMed AirSense 10 / AirCurve 10 / Lumis devices.
  • Do not use liquids to clean any part of the oximeter adapter
  • Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following: excessive ambient light, excessive motion, electromagnetic interference, blood flow restrictors (arterial catheters, blood pressure cuffs, infusing lines, etc.), moisture in the sensor, improperly applied sensor, incorrect sensor type, poor pulse quality, venous pulsations, anaemia or low haemoglobin concentrations, cardiogreen or other intravascular dyes, carboxyhaemoglobin, methaemoglobin, dysfunctional haemoglobin, artificial nails or fingernail polish, or a sensor not at heart level.
    Note: Any serious incident that has occured in relation to this device should be reported to ResMed and the competent authority in your country.

Limited warranty
Refer to your device User Guide

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ResMed User Manuals

Related Manuals