aquasana AQ-SFRO-S2 Under Sink Water Filter Instruction Manual
- June 12, 2024
- aquasana
Table of Contents
aquasana AQ-SFRO-S2 Under Sink Water Filter
Product Information
The AQ-SFRO-S2 is an under sink water filter system manufactured by Aquasana, Inc. It is certified by WQA to NSF/ANSI Standard 58 and CSA B483.1 for its performance in reducing contaminants. The system uses a SmartFlowTM Reverse Osmosis Membrane for effective filtration.
The system is designed to remove a wide range of contaminants from your water supply. For a full list of filtered contaminants, refer to the Performance Data Sheet available on the Aquasana website.
The recommended replacement frequency for the AQ-SFRO-S2 is every 12 months. To maintain optimal contaminant removal and system performance, it is important to use only certified, genuine Aquasana replacement filters.
Product Usage Instructions
-
Prepare for Installation:
- Turn off the COLD water valve.
- Release pressure from the system by turning on the dedicated
faucet until water stops flowing. Once water stops flowing, turn the faucet off.
-
Unbox SmartFlowTM Membrane replacement and remove plastic.
-
Remove the existing SmartFlowTM Membrane cartridge from Stage 2 by turning the handle to the left and pulling it out. Discard the entire cartridge.
-
Insert the new SmartFlowTM Membrane cartridge into Stage 2 in the system manifold by turning it to the right with the handle vertically aligned. Ensure proper alignment using the guides on each filter.
-
Once the filter is engaged, push it fully in while rotating 90 degrees to the right.
-
Flush and Check for Leaks:
- Turn on the COLD water valve and confirm that the dedicated faucet is off.
- While the tank refills, carefully inspect for leaks.
- Note: It may take 1-3 hours for the water tank to refill.
-
After the water tank is full, turn on the dedicated faucet and empty the tank again.
-
Once the water tank is empty, turn off the dedicated faucet and allow the tank to refill. Repeat this step two more times.
-
Once you have emptied three tanks of water, close all faucets and refill for regular use.
Note: Do not drink flushed water during the flushing process.
Care Instructions
To clean the system manifold and tank, wipe the exterior with a damp cloth. Do not use any strong or abrasive cleaning agents or solvent cleaners.
Important: Do not use the AQ-SFRO-S2 with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Refer to the Performance Data Sheet and Arsenic Facts section for information on reduction performance and cyst reduction.
Protect your investment and save money with our Water for Life program
CONTACT US TO LEARN MORE866-662-6885
- Certified by WQA to NSF/ANSI Standard 58 and CSA B483.1 when used in the AQ-SFRO the reduction for the of the claims specified on the Performance Data Sheet and at www.WQA.org.
- For the full list of contaminants filtered, scan to view the Performance Data Sheet on Aquasana.com.
The recommended replacement frequency for the AQ-SFRO-S2 is every 12 months. Use only certified, genuine Aquasana replacement filters for continued contaminant removal and system performance.
INSTALLATION STEPS
Prepare for Installation
- Turn off COLD water valve. Release pressure from system by turning on dedicated faucet until water stops flowing. Once water stops flowing from the dedicated faucet, turn the faucet off.
- Unbox SmartFlow™ Membrane replacement and remove plastic.
- Remove the SmartFlow™ Membrane cartridge from Stage 2 by turning the handle to the left and pulling out. Discard entire cartridge.
Insert Smartflow™ Membrane
- Insert SmartFlow™ Membrane cartridge into Stage 2 in the system manifold by turning to the right with the handle vertically aligned. The guides on each filter will ensure proper alignment within the system manifold.
- Once the filter is engaged, push the filter fully in while rotating 90 degrees to the right.
Flush and Check for Leaks
NOTE: Do not drink flushed water.
- Turn on COLD water valve and confirm dedicated faucet is off. While tank refills, carefully inspect for leaks.
NOTE: It will take 1-3 hours for the water tank to refill.
- After the water tank is full, turn on the dedicated faucet and empty the tank again.
- Once the water tank is empty, turn off the dedicated faucet and allow tank to refill. Repeat this step two more times. Once you have emptied three tanks of water, close all faucets and refill for regular use.
Care
- To clean the system manifold and tank, wipe exterior with a damp cloth.
- Do not use any strong or abrasive cleaning agent or solvent cleaner.
NOTICE – Safeguards: If you are experiencing a tubing connection leak, shut off COLD water, disconnect and re-set the tube.
- Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
- Conforms to NSF/ANSI 58 for pentavalent arsenic reduction. See Performance Data Sheet and Arsenic Facts section for an explanation of reduction performance.
- Systems certified for cyst reduction may be used on disinfect waters that may contain filterable cysts.
Scan to view the SmartFlow™ Reverse Osmosis filter replacement video.
Aquasana, Inc
- 4343 S. Hamilton Road
- Groveport, OH 43125
- 866-662-6885 USA
- 877-332-7873 Canada
- www.aquasana.com.