Not mentioned ETV1-HCP Electromechanical Door Locking Instruction Manual

June 12, 2024
Not mentioned

Not mentioned ETV1-HCP Electromechanical Door Locking Instruction Manual

About these instructions

Dear Customer,
We thank you for choosing a quality product from our company. These instructions are original operating instructions in accordance with EC Directive 2006/42/EC.

These instructions contain important information on the product.

  • Read through all of the instructions carefully.
  • Please observe the information. Please pay particular attention to the safety instructions and warnings.
  • Keep these instructions in a safe place for later reference.
  • Make sure that these instructions are available to the user at all times.

Further applicable documents
The following documents for safe handling and maintenance of the system are placed at the disposal of the end user:

  • These instructions
Definitions used

DIL switches
Switches on the control circuit board for setting the control.

Closed end-of-travel position
In this door position door locking ETV1-HCP automatically releases or locks. Locking element ETV1 is locked manually via an external control unit.

Door system
A door with the associated operator and control.

Safety instructions

 ATTENTION: 

IMPORTANT SAFETY INSTRUCTIONS.
FOR THE SAFETY OF PERSONS, IT IS IMPORTANT TO COMPLY WITH THE FOLLOWING INSTRUCTIONS. THESE INSTRUCTIONS MUST BE KEPT. For undated references to standards, directives etc. referred to here, the latest version of the publication applies, including any amendments.

Intended use
The electromechanical door locking is intended for locking sectional and roller garage doors. You may use the electromechanical door locking for both private and commercial applications. Note the manufacturer’s specifications regarding the door and operator combination. EN 13241 specifies the application for installation, fitting and use.

Non-intended use
Not permitted for use on enclosure doors.

Fitting

Clearance required
Fitting

Fitting to sectional doors
Fitting Instruction
Fitting Instruction
Fitting Instruction

Fitting to rolling shutter DD

Fitting Instruction
Fitting Instruction

Installation

Electrical installation
This section describes the fitting and connection of further add-on parts. For the electrical installation of circuits with dangerous voltages, observe the control instructions.

ATTENTION

Locked bolt
There is a danger of injury and damage in the door’s area of travel due to the extended bolt of an unregistered locking element.

  • A BUS scan must be performed before the first door run of the HCP variant.
  • The static current circuit must be connected to the operator before the first door run of the ETV variant.

Automation of the ETV1 requires the end-of-travel positions to be captured. The multi-function circuit board or travel limit circuit board, for example, can be used for this purpose.

Activate the start warning (5 s)

  • Set the correct settings in the menus for controls A /B 4XX(R) and 360: Menu 09 parameter 05, menu 18 parameter 06 and menu 19 parameter 02

NOTE
The automatic timer is not possible when the start warning is activated.
Installation
Installation

Functioning

The locking element functions (ETV1)/ address (ETV1-HCP) can be set via DIL switches. Before initial start-up, all DIL switches are set to OFF (factory setting). Changes to the DIL switch settings are only permissible under the following conditions:

  • ETV1: The locking element is at rest
  • ETV1-HCP: The user performs a BUS scan after adjusting

DIL switch ETV1-HCP
In case of multiple locking elements with HCP, the number of DIL switches has to be set.

DILswitches Status
BUS address for locking element 1
BUS address for locking element 2
BUS address for locking element 3
BUS address for locking element 4

DIL switch ETV1

DIL switches Status Output signal
a: Not locked

b: Locked
| Without function|
| c: Not locked (2 Hz cycle)|
d: Bolt moved manually (10 Hz cycle)
| Without function|

Functioning of ETV1-HCP

Basic system setting
Basic system setting

When voltage is supplied, the locking element moves to the released position.

Normal operation
Normal operation

Normal operation CLOSE door travel

Normal operation OPEN door travel

Manual release
Operating Instruction

After manual release, move the knob back to its original position

Error condition
The locking element stops as soon as there is an error

Functioning of ETV1

Static current circuit
When the static current circuit is opened, the locking element and operator remain in the current status.

Normal operation

When voltage is supplied, the locking element moves to the released position.

Normal operation locking
Operating Instruction

Normal operation release

  • The static current circuit must be connected to the operator
    Operating Instruction

Manual release

  • The static current circuit must be connected to the operator
    Operating Instruction

Error condition
The locking element stops as soon as there is an error

Initial start-up

Instructing users
All persons using the door system must be shown how to operate the locking element properly and safely.

Perform a BUS scan
Perform a BUS scan before the first door run.

Emergency operation devices
Fast emergency release
emergency release

CAUTION

Release
There is a danger of injury and damage in the door’s area of travel

  • The release may only be actuated by instructed personnel while the door is closed.

Preparations

  • Fasten knob to locking element with screw (Fig. 16a.1).

Release

  • Turn the red knob 90° anti-clockwise and pull (Fig. 16a.2)
  • Then return the knob to its original position.

Secured emergency release

  • Insert a slotted screwdriver into the rotary latch, turn 90° anti-clockwise and pull on the knob (Fig. 16b).
  • Then return the rotary latch to its original position

EC / EU Declaration of Conformity /

Declaration of Incorporation

Hörmann KG Verkaufsgesellschaft herewith declares that the electromechanical locking element complies with the Directive 2014/53/EU. The complete text of the EU Declaration of Conformity can be found on the following website:

Dismantling
Have a specialist dismantle the locking element in the reverse order of these instructions.

  Disposal

Dispose of the packaging sorted by materials

Electrical and electronic devices
must be disposed of at the appropriate recycling facilities.

Dispose of the batteries separately
Each consumer is legally required to leave batteries with a collection point in their community, their district, or with a trader.

Technical data

Rated operating voltage 24 V DC
Power consumption in standbylocked / released 15 mA
Power consumption in operationlock / release 100 mA
Locking bolt Galvanized steel, Ø 12 mm, bolt travel 24 mm
Close / open time Approx. 1.5 s
Working temperature range −20 °C to +60 °C
Protection category IP22
Housing dimensions Width (including bolt)
Depth 55 mm
Height (including screw fitting) 246 mm

Displaying errors, warnings and operating modes

Operating condition display ETV1-HCP
LED display red (RD)

Continuously illuminated ETV1 is connected to control / operator in “released” positionFlashes quickly  on   off1s           2s             3s    14 × in 3 sETV1 is connected to control / operator traveling to “released” position

Condition Definition of flash frequencies Function

3 × very fast flashing with break in flashing, followed by slow green flashing| | A BUS scan is being performed (searching for new ETV1-HCP on the HCP bus)

LED display green (GN)

Condition Definition of flash frequencies Function
Flashes slowly ETV1-HCP is not connected to control / operator
Continuously illuminated ETV1-HCP isconnected to control / operator in

“locked” position
Flashes quickly| | ETV1 is connected to control / operator traveling to “locked” position

Operating condition display ETV1

LED display red (RD)

Condition Definition of flash frequencies Function
Continuously illuminated “Released” position
Flashes quickly Traveling to “released” position

LED display green (GN)

Condition Definition of flash frequencies Function
Continuously illuminated ETV1 is connected to control / operator in

“locked” position
Flashes quickly| | ETV1 is connected to control / operator traveling to “locked” position

Error message ETV1-HCP / ETV1
The last error is displayed. As soon as there is an error or an error is acknowledged, an acoustic signal is emitted 3 × on the locking element.

LED display red (RD)

Display Error / warning Possible cause Remedy
Flashes slowly 5 × The maximum motor run time has been exceeded Motor
faulty
Flashes slowly 6 × The maximum motor current has been exceeded Sluggish
mechanics Move ETV manually and check for sluggishness
Flashes slowly 7 × Bolt blocked Bolt blocked by frame / roller Check

fitting position