Thank you for choosing a ResMed USB adapter.
Intended Use
Used with ResMed devices, the USB adapters transmit patient therapy data
between the device and Tx Link for sleep studies.
The Air10 USB adapter shown in illustration A is compatible with AirSense™ 10
/ AirCurve™ 10 / Lumis™ devices. The S9™ USB adapter shown in illustration B
is compatible with S9 devices.
Before using the USB adapter, read the entire guide together with the device
User Guide.
The USB adapter is intended to be used in a clinical environment only.
Note: Not all devices are available in all regions.
USB adapter at a glance
The USB adapter comprises the following elements:
- USB adapter
- USB cable.
Air10 USB adapter | S9 USB adapter |
---|---|
Refer to illustration A: | Refer to illustration B: |
1. Adapter connector | 1. USB cable connector port |
2. Release button | 2. Release buttons |
3. USB cable connector port. | 3. Adapter clip |
4. Adapter connector. |
AirSense 10 / AirCurve 10/Lumis S9
Refer to illustration C: | Refer to illustration D: |
---|---|
1. SD card cover | 1. DC Power inlet |
2. Air filter cover | 2. Adapter clip socket |
3. Adapter cover | 3. Adapter port |
4. Adapter port. | 4. SD card slot |
5. Alarm (Bilevel alarmed devices only). |
Software compatibility
Ensure the PC intended for use has the appropriate ResMed patient management
software installed.
| Air10| S9
---|---|---
AirView| |
ResScan v4.0 or greater| |
For a full list of compatible software refer to the Data Management Device
Compatibility List on www.resmed.com.
Setting up
See illustration E or F:
- Ensure the device is disconnected from the power outlet.
- Connect the USB adapter to the device.
- Connect one end of the USB cable to the USB adapter and the other to the Tx Link or ResScan (S9 USB adapter only).
- Reconnect the device to the power outlet.
You can now perform sleep studies, or download data (S9 USB adapter only).
For more information, refer to the online software help. When the sleep
studies or data download are complete, you can remove the USB adapter if
required.
Note: If you need help or to report an unexpected issue, contact a ResMed
representative, ResMed Technical services or see
www.resmed.com.
Removing the USB adapter
- Disconnect the device from the power outlet.
- Press the release button/s on the side of the USB adapter and pull gently to remove it from the device.
Cleaning and maintenance
- Disconnect the device from the power outlet and remove the USB adapter.
- Wipe the exterior of the USB adapter with a clean, dry cloth. The contacts do not require cleaning.
Technical specifications
Operating temperature | +41°F to +95°F (+5°C to +35°C) |
---|---|
Operating humidity | 10 to 95% non-condensing |
Operating altitude | Refer to your device User Guide for details. |
Storage and transport temperature | -4°F to 140°F (-20°C to +60°C) |
Storage and transport humidity
Air10
S9| 5 to 95% non-condensing
10 to 95% non-condensing
Design life
Air10| 1,825 connections
S9| 1,825 connections
Gross dimension
Air10 (W x D x H)| 2.1″ x 1.2″ x 2.0″
(54 mm x 30 mm x 51 mm)
S9 (L x W x H)| 1.74″ x 2.12″ x 0.91″
(44.35 mm x 54.10 mm x 23.30 mm)
Weight
Air10| 0.88 oz (25 g)
S9| 0.77 oz (22.1 g)
Electromagnetic compatibility| Refer to your device User Guide for details.
Note: The manufacturer reserves the right to change these specifications without notice.
Symbols
The following symbols may appear on the USB adapter or packaging:
Caution/Warning. Read instructions before use. Manufacturer.
European Authorized Representative. LOT Batch code. Catalog number.
Serial number. IP21 Protection against insertion of fingers nd against
vertically dripping water. IP22 Protected against finger sized objects and
against dripping water when tilted up to 15 degrees from specified
orientation.
Humidity limitation. Temperature limitation. European RoHS. China pollution
control logo. Importer. Medical device.
Notes:
- IP21 rating applies only to S9 USB adapter without USB cable attached.
- IP22 rating applies only to Air10 USB adapter.
Environmental information
This device should be disposed of separately, not as unsorted municipal waste.
To dispose of your device, you should use appropriate collection, reuse and
recycling systems available in your region. The use of these collection, reuse
and recycling systems is designed to reduce pressure on natural resources and
prevent hazardous substances from damaging the environment.
If you need information on these disposal systems, please contact your local
waste administration. The crossed-bin symbol invites you to use these disposal
systems. If you require information on collection and disposal of your ResMed
device please contact your ResMed office, local distributor or go to
www.resmed.com/environment.
WARNING
Do not open or modify the USB adapter. The USB adapter is not designed to be
serviced. There are no serviceable parts inside.
CAUTION
- In the US, Federal law restricts this device to sale by or on the order of a physician.
- Only use the USB adapter as specified in this guide.
- S9 USB adapters are specifically designed for use with ResMed S9 devices.
- Air10 USB adapters are specifically designed for use with the ResMed AirSense 10 / AirCurve 10 / Lumis devices.
- Do not use liquids to clean any part of the USB adapter.
Note: Any serious incident that has occured in relation to this device should be reported to ResMed and to the competent authority in your country.
Limited warranty
Please refer to your device User Guide.
ResMed Pty Ltd
1 Elizabeth Macarthur Drive
Bella Vista NSW 2153 Australia
See ResMed.com for other ResMed locations worldwide. For patent information,
see ResMed.com/ ip. Air10,
AirCurve, AirSense, AirView, Lumis, ResScan and S9 are trademarks of ResMed.
S9 is registered in U.S. Patent and
Trademark Office. © 2023 ResMed. 3781091/2 2023-06
ResMed.com
References
- Sleep apnea and COPD - learn about symptoms and treatment | ResMed
- Environmental policy - ResMed
- Sleep apnea and COPD - learn about symptoms and treatment | ResMed
- Environmental policy - ResMed
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>