WESTFIRE WF35 Wood Burner Installation Guide
- June 4, 2024
- WESTFIRE
Table of Contents
WF35
INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
PRODUCT SHEET
Energy Labelling Directive – ( EU ) 2015/1186 for Solid Fuel Boilers and
Packages of Solid Fuel Boilers, Supplementary
Heaters, Temperature Controls, and Solar Devices
WF35 Wood Burner
Producent | Westfire ApS |
---|---|
Model | Westfire 35 |
Energy Efficiency Class | A |
Nominal Heat Output to Room | 4.6 kW |
Nominal Heat Output to Water | 0 kW |
Seasonal Space Efficiency ( EEI ) | 104 |
Net Efficiency | 78% |
Specific precautions when installed or maintained | See the Instructions manual |
INSTALLATION MANUAL AND OPERATING INSTRUCTIONS
WF35/UNIQ35, UNIQ35 inset
This manual refers to the stove types listed above, which have been tested in
accordance with EN13240.
Please read this manual carefully in order to ensure that you get maximum
enjoyment from your new stove and to prevent any problems. Please note that
“all local regulations, including those referring to national and European
Standards, need to be complied with when installing this appliance”. For
further information on installing and using fireplaces and multi-fuel stoves,
please see the relevant building regulations that apply to the country in
which WEST FIRE UNIQ 35 has been approved.
These instructions cover the basic principles to ensure the satisfactory
installation of the WEST FIRE UNIQ35 stove, although the detail may need
slight modification to suit particular local site conditions.
In all cases, the installation must comply with current Building Regulations,
Local Authority Byelaws, and other specifications or regulations as they
affect the installation of the stove.
It should be noted that the Building Regulations requirements may be met by
adopting the relevant recommendations given in British Standards BS EB 8303,
BS EN 15287 design, installation, and commissioning of chimneys as an
alternative means to achieve an equivalent level of performance to that
obtained following the guidance given in Approved DocumentJ.
HEALTH AND SAFETY PRECAUTIONS
Special care must be taken when installing the stove such that the
requirements of the Health and Safety at Work Acts are met.
Handling
Adequate facilities must be available for loading, unloading, and site
handling.
Fire Cement
Some types of fire cement are caustic and should not be allowed to come into
contact with the skin. In case of contact wash immediately with plenty of
water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any
asbestos in the course of installation then please seek specialist guidance
and use appropriate protective equipment.
CO Alarms
Building regulations require that whenever a new or replacement fixed solid
fuel or wood/biomass appliance is installed in a dwelling a carbon monoxide
alarm must be fitted in the same room as the appliance. Further guidance on
the installation of the carbon monoxide alarm is available in BS EN 50292:2002
and from the alarm manufacturer’s instructions. The provision of an alarm must
not be considered a substitute for either installing the appliance correctly
or ensuring regular servicing and maintenance of the appliance and chimney
system.
Metal Parts
When installing or servicing this stove care should be taken to avoid the
possibility of personal injury.
Stove paint Aerosols
Paint aerosols are flammable and therefore dangerous to use around a lit
stove. Be sure to allow aerosol spray paints to dry and ventilate the room
well before lighting the stove. The use of any aerosol around a lit stove is
dangerous and care must be taken in handling aerosols.
WEST FIRE UNIQ 35
Model choice| UNIQ 35 Standard| UNIQ 35 PEDESTAL|
UNIQ 35 Inset
---|---|---|---
| 50mm base| 400mm pedestal| 3 sided frame| 4 sided frame
Closed combustion| Yes| Yes| Yes| Yes
STOVE PERFORMANCE & TESTING
Westfire Uniq 35 models have been approved in accordance with EN 13240.
Stove model| Efficiency| Weight| Nominal heat output|
CO@ 13% 02
---|---|---|---|---
Wood/coal| Wood| Smokeless fuels| Wood/coal
UNIQ 35 standard| 78%/76%| 80kg| 4.6 KW| 3.7 KW| .12/.17
UNIQ 35 pedestal| 78%/76%| 110kg| 4.6 KW| 3.7 KW| .12/.17
PREPARATORY WORK AND SAFETY CHECKS – IMPORTANT WARNING
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating
appliance.
There must not be an extractor fan fitted in the same room as the stove as
this can cause the stove to emit fumes into the room.
Chimney – Chimney Connection
Flue Diameter 125mm
In order for the stove to perform satisfactorily, the chimney height must be
sufficient to ensure an adequate draught so as to clear the products of
combustion and prevent smoke problems in the room.
| Flue gas flow rate wood /coal| Test flue gas temperature wood
/coal| @ pascals of pressure
---|---|---|---
UNIQ 35| 4.6/ 4.7g/sec| 259/240c| 12
NOTE: A chimney height of not less than 4.5 meters measured vertically
from the outlet of the stove to the top of the chimney should be satisfactory.
Alternatively, the calculation procedure given in BS 5854:1980 may be used as
the basis for deciding whether a particular chimney design will provide
sufficient draught. The outlet from the chimney should be above the roof of
the building in accordance with the provisions of Building Regulations
Approved Document J.
If the installation is into an existing chimney then it must be sound and have
no cracks or other faults which might allow fumes into the house. Older
properties, especially, may have chimney faults or the cross-section may be
too large i.e. more than 160 mm x 160 mm. Remedial action should be taken, if
required, seeking expert advice. If it is found necessary to line the chimney
then a flue liner suitable for solid fuel must be used in accordance with
Building Regulations Approved Document J.
Any existing chimney must be clear of obstruction and have been swept clean
immediately before installation of the stove. If the stove is fitted in place
of an open fire then the chimney should be swept one month after installation
to clear any soot falls which may have occurred due to the difference in
combustion between the stove and the open fire.
If there is no existing chimney then either a prefabricated block chimney in
accordance with Building Regulations Approved Document J or a twin walled
insulated stainless steel flue to BS 4543 can be used. These chimneys must be
fitted in accordance with the manufacturer’s instructions and Building
Regulations.
A single wall metal flue pipe is suitable for connecting the stove to the
chimney but is not suitable for use for the complete chimney. The chimney and
connecting flue pipe must have a minimum diameter of 125 mm and its dimension
should be not less than the size of the outlet socket of the stove. Any bend
in the chimney or connecting flue pipe should not exceed 45°. 90° bends should
not be used.
If it is found that there is excessive draught in the chimney then either an
adjustable flue damper or alternatively a draught stabilizer should be fitted.
The adjustable flue damper should not close off the flue entirely but should
in its closed position leave a minimum continuous opening free area of at
least 20 % of the total cross-sectional area of the flue or flue pipe.
Adequate provision e.g. easily accessible soot door or doors must be provided
for sweeping the chimney and connecting flue pipe.
WF UNIQ 35 Dimensions
| UNIQ 35 Standard| UNIQ 35 PEDESTAL| UNIQ 35
INSET
---|---|---|---
| | | Stove| Frame 4 sided| Frame 3 sided
Height| 590mm| 985mm| 555mm| 625mm| 590mm
Width| 390mm| 390mm| 390mm| 480mm| 480mm
Depth| 350mm| 350mm| 345mm|
Closed combustion as std| Yes| Yes| Yes|
Distance to Combustible materials
Combustible materials should not be located where the heat dissipating through
the walls of fireplaces or flues could ignite it. Therefore when installing
the stove in the presence of combustible materials due account must be taken
of the guidance on the separation of combustible material given in Building
Regulations Approved Document J and also in these stove instructions.
WESTFIRE | WF UNIQ 35 |
---|---|
Distance to combustible materials rear | 200mm |
Distance to combustible materials side | 200mm |
The minimum distances to flammable materials are specified on the EN 13240
plate on the back of the stove.
Hearth
The hearth should be able to accommodate the weight of the stove and its
chimney if the chimney is not independently supported.
The WEST FIRE UNIQ 35 stove has been tested and is suitable to be installed on
a 12mm non-combustible plate such as Westfire 12mm glass plates or 20mm slate
plates. installation of all hearths should comply with size and construction
so that it is in accordance with the provisions of the current Building
Regulations Approved Document J. The clearance distances to combustible
material beneath, surrounding, or upon the hearth and walls adjacent to the
hearth should comply with the guidance on the separation of combustible
material given in Building Regulations Approved Document J and also in these
stove instructions.
If the stove is to be installed on a wooden floor, it must be covered with a
non-combustible material of at least 12mm thick, in accordance with Building
Regulations, Approved Document J, to a distance of 30 cm in front of the
stove and 15 cm to each side measuring from the door of the combustion
chamber.
Combustion air supply
In order for the stove to perform efficiently and safely, there should be an
adequate air supply into the room in which the stove is installed to provide
combustion air. This is particularly necessary if the room is double-glazed or
a flue draught stabilizer is operating in the same room as the appliance. The
provision of air supply to the stove must be in accordance with current
Building Regulations Approved Document J. An opening window is not appropriate
for this purpose. Air inlets must be positioned in such a way that they cannot
be blocked. An air inlet may be a vent (the vent must be open and the capacity
of the vent sufficient when the stove is lit) or a fresh air system linked to
the stove.
The WEST FIRE UNIQ 35 is fitted as standard with a closed air supply collar,
this enables the stove to take all combustion air (primary, secondary and
tertiary) directly from outside with an 80mm pipe from the stove.
There are no European rules regarding the minimum distance to non-flammable
walls, Westfire recommends leaving a gap of at least 10 cm behind and to the
sides of the stove.
FLUE AND AIR INTAKE POSITIONS
| UNIQ 35 Standard| UNIQ 35 Pedestal| UNIQ
35 inset
---|---|---|---
Distance from front to the center of top flue exit| n/a| n/a| 335mm
Distance from rear to center of top flue exit| 120mm| 120mm| n/a
Distance from floor to center of external air intake| 115mm| 505mm| 65mm
Westfire Insulated chambers
The WEST FIRE UNIQ 35 stove is lined with vermiculite heat deflection panels
and baffles, these panels are designed to ensure maximum efficiency and are an
integral part of the clean burn process of the stove. These baffles should not
be removed other than for cleaning the stove. Any panels showing significant
ware should be replaced.
Connection to chimney
The WEST FIRE UNIQ 35 stoves are factory set up with a top flue outlet only;
the flue outlet can be altered on the inset model by removing the collar and
rotating 180 degrees and re-bolting. This will give a collar that is now at a
45-degree angle. Care should be taken to ensure an airtight fit when refitting
the collar. This collar allows connection to either a stainless steel chimney
liner or a prefabricated factory-made insulated metal chimney. Westfire DO NOT
recommend installation of this appliance directly into a masonry chimney.
Commissioning and handover
On completion of the installation allow a suitable period of time for any fire
cement and mortar to dry out, a small fire may be lit to check that smoke and
fumes are taken from the stove up the chimney and emitted safely into the
atmosphere. Do not run at full output for at least 24 hours.
On completion of the installation and commissioning ensure that the operating
instructions for the stove are left with the customer. Ensure to advise the
customer on the correct use of the appliance with the fuels likely to be used
on the stove and notify them to use only the recommended fuels for the stove.
Advise the user on what to do should smoke or fumes be emitted from the stove.
The customer should be warned to use a fireguard to BS 6539 in the presence of
children, aged, and/or infirm persons.
OPERATION & MAINTENANCE OF YOUR APPLIANCE
Congratulations on the purchase of your new Uniq 35 new multi-fuel stove from
Westfire ApS. The Westfire UNIQ 35 is constructed in steel with a vermiculite
insulated chamber.
Please read this manual carefully in order to ensure that you get maximum
enjoyment from your new stove and to prevent any problems. Please note that
“all local regulations, including those referring to national and European
Standards, need to be complied with when installing this appliance”.
Warning
CO Alarm: Your installer should have fitted a CO alarm in the same room as the
appliance. If the alarm sounds unexpectedly, follow the instructions given
under “Warning Note” above. Use a fireguard in the presence of children, and
old and/or infirm people. The fireguard should be manufactured in accordance
with BS 8423:2002, Fireguards for use with solid fuel appliances.
OPERATING YOUR STOVE- WEST FIRE UNIQ 35 – CONTROLS
PRIMARY AIR CONTROL SETTINGS
Burning wood position 1 to position 2
When burning wood use primary air control from position 1 (fully pushed in) to
position 2 (when controls stop midway). Do not move beyond this position for
wood burning.
Burning wood position 3 to position 4
When burning coal the primary air control drops to position 3 (midpoint
location) operate and regulate your stove between positions 3 and 4 (fully
pulled out).
The first lighting of your stove
The heat-resistant paint on your stove will cure and harden the first time you
light your appliance. The curing process produces a good deal of smoke and
odor, it is therefore important that the first time you light your stove the
room should be well ventilated. During the process, it is important to open
and close the stove door periodically (every 30mins) during the first couple
of firings, therefore, preventing the door seal cord around the door from
sticking and coming away from the door. Once the heat-resistant paint has
hardened the smell will disappear. This stove is NOT designed to be used with
the door open, the stove door must be kept closed except when lighting the
stove, adding firewood, or removing ash in order to prevent flue gases from
escaping. The door does not operate the appliance with the ash pan removed or
open.
Lighting your appliance
Quality Firelighters should be used when lighting the stove. (Never use
mentholated spirit, petrol, or other flammable liquids). Lighting your stove
with firelighters will be more reliable and easier than using paper.
UNIQ 35 RELOAD WEIGHTS
| 1 HR RELOAD| 2 HOUR RELOAD
---|---|---
WOOD (HARDWOOD LOGS)| 1.2kg| 1,2kg
SMOKELESS COAL BRIQUETTES (REGISTERED ONLY)| N/A| 1.1kg
To light your stove Wood
-
Place a few smaller pieces of dry wood (kindling) on the stove on top of the nontoxic firelighters, and place one or two small dry splits (¼ split) logs on top.
-
Fully open the secondary air control above the stove door on the right-hand side. Fully open primary air control at the base left of the stove. The Uniq 35 stoves air controls are now fully open.
-
Light the firelighters and push the door to the closed position and close the handle to 1st position; this will allow a small gap in the door for more air to be supplied to the stove during the ignition period.
-
When the flames are established and the fire is burning brightly push the door latch to position 2 fully closed.
-
Once the fire is burning brightly again close the primary air control. This will close off the primary air to the stove.
If the stove begins to falter after the primary is closed, open primary control again and leave until the fire has established, then close. -
The fire should now be fully established and burning brightly. At this stage close secondary air control by 50%, this is the operational setting. For the stove to burn cleanly and efficiently plenty of secondary air is needed, do not be tempted to shut the fire down too early as this may cause smoke. At nominal heat output, expect to refuel your stove once an hour.
The WEST FIRE UNIQ 35 stove is equipped with manual regulating control for
secondary air; this is designed to ensure a plentiful supply of oxygen during
firing. It is important therefore to not fully close the secondary air
control.
When lit, the stove will get very hot and due care must therefore be
exercised. Please use a glove and operating tool supplied when operating air
controls and riddlers.
RE-FUELING wood
To refuel your stove in the cleanest way.
Only refuel your stove when flames have died down and you have glowing embers.
Before refueling, open secondary air control fully, and open primary air
control fully. Open the door, and add two pieces of split wood measuring
approximately 20cm with a combined weight of 1.15kg. Close the door and leave
the primary and secondary air controls open until a fire is re-established
with flames. Close primary air control and slide secondary air control to the
operational position (40% open).
BURNING WOOD IN A SMOKE CONTROL AREA
You must purchase a smoke control version of the Westfire Uniq 35 stove which
is modified slightly to comply with regulations. Any change to this
modification will invalidate the stove’s compliance with smoke control areas.
The Clean Air Act 1993 and Smoke Control Areas
Under the Clean Air Act, local authorities may declare the whole or part of
the district of the authority to be a smoke control area. It is an offense to
emit smoke from a chimney of a building, from a furnace, or from any fixed
boiler if located in a designated smoke control area. It is also an offense to
acquire an “unauthorized fuel” for use within a smoke control area unless it
is used in an “exempt” appliance (“exempted” from the controls which generally
apply in the smoke control area).
The Secretary of State for Environment, Food and Rural Affairs has powers
under the Act to authorize smokeless fuels or exempt appliances for use in
smoke control areas in England. In Scotland and Wales, this power rests with
Ministers in the devolved administrations for those countries. Separate
legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern
Ireland. Therefore it is a requirement that fuels burnt or obtained for use in
smoke control areas have been “authorized” in Regulations and that appliances
used to burn solid fuel in those areas (other than “authorized” fuels) have
been exempted by an Order made and signed by the Secretary of State or
Minister in the devolved administrations.
Further information on the requirements of the Clean Air Act can be found
here: http://smokecontrol.defra.gov. UK/
Your local authority is responsible for implementing the Clean Air Act 1993
including designation and supervision of smoke control areas and you can
contact them for details of Clean Air Act requirements
Using your stove in a smoke control zone.
Only specific SE models are suitable for smoke control areas (see page 4),
alterations should not be attempted. Westfire smoke control stoves should not
be burnt with the door left open.
The refueling procedure: allow the newly charged fuel to burn with the
secondary air control set at maximum for up 3 to 4 minutes. After this period,
with flames from the logs fully established, close the secondary air supply to
the low output setting. When operating at the high output (secondary air set
fully open) the new refuel charge does not require any boost air to establish
combustion.
Refueling onto a low fire bed
If there is insufficient burning material in the firebed to light a new fuel
charge, excessive smoke emissions can occur. Refueling must be carried out
onto a sufficient quantity of glowing embers and ash that the new fuel charge
will ignite in a reasonable period. If there are too few embers in the fire
bed, add suitable kindling to prevent excessive smoke.
To light your stove Smokeless Coal
- Place a few smaller pieces of dry wood (kindling) on the stove on top of the nontoxic firelighters, and place one or two small dry splits and a small quantity of Smokeless coal.
- Fully open the secondary air control above the stove door on the right-hand side. Fully open primary air control at the base left of the stove. Pull open the coal switch. The Uniq 35 stoves air controls are now fully open.
- Light the firelighters and push the door to the closed position and close the handle to 1st position; this will allow a small gap in the door for more air to be supplied to the stove during the ignition period.
- When the flames are established and the fire is burning brightly load 1.1 kg of smokeless coal and close the door latch to position 2 fully closed.
- Once the fire is burning maintain the secondary air control 100%.
- Now the fully established fire bed is burning brightly. Maintain primary air control at 100%, this is the operational setting. For the stove to burn cleanly and efficiently primary air is needed, do not be tempted to shut the fire down too early as this may cause smoke. At nominal heat output, expect to refuel your stove once every two hours. When lit, the stove will get very hot and due care must therefore be exercised. Please use a glove and operating tool supplied when operating air controls.
RE-FUELING Smokeless fuel
To refuel your stove. Only refuel your stove when flames have died down and
you have glowing embers.
Before refueling open secondary air control fully, and open primary air
control fully. Open the door and re-load 1.1 kg of smokeless coal. Close the
door and leave the primary and secondary air controls open until a fire is re-
established. Maintain secondary air control at 100% and maintain primary air
control to its operational position (100% open).
Operational Position of air controls during operation and in adverse
conditions
You need to become familiar with your stove in order to be able to regulate
the air controls correctly, as outside factors such as the quality and height
of your chimney, the quality of your fuel, and the external weather conditions
can alter the stove’s operational settings and performance.
Very damp weather can affect the draw of the stove and therefore more
secondary air may be needed to adjust.
Very still cold clear days induce more draught and the setting for secondary
air may be less than nominal settings.
Such accommodations will become normal once you are familiar with your stove.
It is easy to see whether the stove is functioning correctly; incomplete
combustion will be shown by
- The inside of the fire chamber firebricks have a black dusty build-up,
- A build-up of hard shiny soot on the inside of the glass
- Smoking chimney.
To prevent sooting of the chamber and glass introduce more secondary air, also check that your wood is dry.
It is important to check the draft conditions before lighting your stove. This may be done, for instance, by crumpling a piece of newspaper, placing it in the combustion chamber, and lighting it. The draft conditions are good if the smoke is drawn away through the chimney.
Door operation
When opening the door of your Westfire stove always wear the glove that is
provided to protect your hand from possible heat. The handle pulls out away
from the door. When shutting the door push the door closed and push the handle
firmly to the second closed position. The WF UNIQ 35 door handle has two
positions position 1 holds the door slightly ajar for starting, and position 2
is fully closed.
Recommended Fuels
Good quality wood is the most important factor in your stove working
efficiently and cleanly. Always use dry split firewood. The dryness of the
firewood plays an important role since the use of wet wood results in poor
fuel economy and may cause a tarry sooty film on the internals of the stove.
The Westfire UNIQ 35 is tested to burn wood and smokeless coal. Wood
briquettes can also be burnt but load weight should be strictly adhered to.
For a full list of suitable fuels, check with the official solid fuels
approvals body, HETAS, or Solid Fuel Association. Do not overload the stove as
this can cause excessive heat and damage the stove. ALWAYS KEEP FUEL LOAD
BELOW TERTIARY PORTS AT THE REAR OF THE STOVE.
Only use fuels approved for use on heating stoves.
Do not burn liquid fuels, driftwood, finished wood, sawn wood, pallet wood,
chipboard/plywood, varnished wood or plastic coated wood, wood treated with
preservatives, or house hold waste.
DO NOT EXCEED SPECIFIED FUEL WEIGHTS.
DO NOT BURN HOUSE COAL. DO NOT BURN HOUSEHOLD WASTE; THIS APPLIANCE IS NOT
AN INCINERATOR.
HOUSE COAL AND PETROLEUM COKE ARE NOT SUITABLE FOR USE ON THIS STOVE; THEIR
USE WILL INVALIDATE THE GUARANTEE ESTFIRE RECOMMENDS THE USE OF A FLUE
THERMOSTAT TO CHECK YOUR STOVE IS NOT OVERHEATING. PLACE THE FLUE THERMOSTAT
DIRECTLY ABOVE THE COLLAR OF THE STOVE AND REFER TO THE TEMPERATURE GAUGE IN
THIS MANUAL.
Overnight burning
Westfire UNIQ 35 is designed to burn wood and quality smokeless fuels.
Wood burns more efficiently and cleanly if is burnt hotter and reloaded
regularly. Running your stove with combustion air closed is inefficient and
bad for the environment. Westfire does not recommend that their stoves are
burnt overnight for this reason.
Use of operating tools
Always use the operating tools provided when handling parts likely to be hot
when the stove is in use.
The Westfire Uniq 35 has:
- Heat-resistant glove
- Adjustment tool
- Instruction manual
Maintenance – regular maintenance
Maintenance is an important factor in maintaining the efficient operation of your stove. Please carry out the following actions regularly.
-
Remove ash regularly, do not allow ash to build up and flow over the ash pan. This can interfere with air controls.
Make sure the stove is completely cold before cleaning out ash (embers can remain hot for over 24 hours).
Ash must be stored in a non-combustible container and must not be mixed with other combustible waste. -
Check vermiculite panels, these panels can crack, but this will not affect performance unless the crack grows and the brick breaks down.
-
Clean glass regularly, and do not allow build-up of deposits, regular condensation and acid deposits from combustion cause ceramic glass to whiten and crack. Do not slumber smokeless coal or wood. Clean glass with a lint-free cloth and hot soapy water; do not use an aggressive cleaner. If you have persistent stubborn marks please use a ceramic glass cleaner. Thoroughly dry the glass after cleaning
-
Clean the outside of your stove with a dry lint-free cloth.
-
Check seals for signs of fraying.
Annual service
The inside of the stove should be serviced /cleaned once or twice a year
depending on the amount of use. Your local supplier will be able to carry out
a full service on your appliance. The following steps should be taken
- Clean the inside, and remove all ash, soot, and tar residue from the combustion chamber. Remove insulated chamber panels and baffle, dirt and soot will collect behind it and this must be cleaned out.
- Check the quality of all insulated panels and replace any which are badly damaged,
- Replace stove rope seals
- Check glass is correctly seated and glass seals are in good condition.
- Check air controls
- Check flue ways: the flue pipe connection and the chimney should be checked regularly by a qualified engineer. The chimney should also be checked for blockages before relighting the stove if it has not been used for an extended period of time.
- The paint/ lacquer can wear thin in exposed places due to overheating. This, and other lacquer damage, may be repaired using a Westfire Senotherm paint/lacquer spray available from your Westfire dealer.
- If the appliance is to be dormant for several months (summer) leave open all air controls to allow a flow of air and thus reducing probably of corrosion.
Chimney cleaning
- The chimney should be swept at least once a year for smokeless fuels and a minimum of twice a year for wood and other fuels. It is important that the flue connection and chimney are swept prior to lighting up after a prolonged shutdown period.
- If the stove is fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire.
- In situations where it is not possible to sweep through the stove, the installer will have provided alternative means, such as a soot door. After sweeping the chimney the stove flue outlet and the flue pipe connecting the stove to the chimney must be cleaned with a flue brush.
Aerosols
Aerosols are flammable and therefore dangerous to use around a lit stove. Do
not use aerosol sprays near your lit stove. The use of any aerosol is
dangerous and care must be taken in handling aerosols.
Warning Note
Properly installed, operated, and maintained this stove will not emit fumes
into the dwelling. Occasional fumes from de ashing and re-fuelling may occur.
However, persistent fume emission is potentially dangerous and must not be
tolerated. If fume emission does persist, then the following immediate action
should be taken:
(a) Open doors and windows to ventilate the room and then leave the premises.
(b) Let the fire go out.
(c) Check for flue or chimney blockage and clean if required
(d) Do not attempt to relight the fire until the cause of the fume emission
has been identified and corrected.
If necessary seek expert advice.
The most common cause of fume emission is flue way or chimney blockage. For
your own safety, these must be kept clean at all times.
CO Alarm
Your installer should have fitted a CO alarm in the same room as the
appliance. If the alarm sounds unexpectedly, follow the instructions given
under “Warning Note” above.
Use of fireguard
When using the stove in situations where children, aged, and/or infirm persons
are present a fireguard must be used to prevent accidental contact with the
stove. The fireguard should be manufactured in accordance with BS 8423:2002,
Chimney Fires
If the chimney is thoroughly and regularly swept, chimney fires should not
occur. However, if a chimney fire does occur turn the air controls on your
stove to a minimum, and tightly close the door of the stove. Call the fire
department. Closing the air should cause the chimney fire to go out but do not
open the fire door or controls until the fire is confirmed to be exhausted.
The chimney and flue ways should then be inspected and cleaned by a
professional chimney engineer before any further use.
Permanent air vent
The stove requires a permanent air vent to the room or a direct connection to
the closed airport at the rear of the stove. This is to provide adequate air
supply in order for the stove to operate safely and efficiently.
In accordance with current Building Regulations, the installer may have fitted
a permanent air supply vent into the room in which the stove is installed to
provide combustion air. This air vent should not under any circumstances be
shut off or sealed.
Troubleshooting
-
Fire Will Not Burn – check
a) the air inlet is not obstructed in any way,
b) that chimneys and flue ways are clear,
c) that a suitable fuel is being used,
d) that there is an adequate air supply into the room,
e) that an extractor fan is not fitted in the same room as the fire. -
Fire Blazing out of control – check
a) if the door is tightly closed,
b) the air control is turned down to the minimum setting,
c) the air controls are closed and that it is not prevented from closing completely by a piece of ash,
d) a suitable fuel is being used, do not burn waste wood
e) the door seals are in good condition
f) if the chimney draft may be too strong
g) check ash pan seal and
h) check for ash below the ash pan causing the pan to not seat correctly and clean out. -
Soot forms on the window
a) The firewood may be too wet
b) the intake of secondary air may be insufficient
c) fire not hot enough -
The stove fails to heat fully
a) The firewood may be too wet
b) the intake of secondary air may be insufficient -
Smoke or odor
a) Weak chimney draft
b) check for blockages in the flue pipe/chimney
c) check the height of the chimney in relation to the surroundings -
Soot in the chimney
a) The firewood may be too wet
b) intake of secondary air may be insufficient
IMPORTANT NOTES
General
Before lighting the stove check with the installer that the installation work
and commissioning checks described in the installation instructions have been
carried out correctly and that the chimney has been swept clean, is sound, and
free from any obstructions. As part of the stoves’ commissioning and handover,
the installer should have shown you how to operate the stove correctly.
HETAS Ltd Approval
This appliance has obtained HETAS Ltd approval on a safe and fit-for-purpose
level (single tick approval) for burning wood logs only as detailed in the
list of recommended fuels above. Approval does not cover the use of other
fuels either alone or mixed with the recommended fuels listed, nor does it
cover instructions for the use of other fuels.
Guarantee
Every Westfire stove is designed and built with great care and with the finest
materials. Ensuring quality control is an integral part of the production
process.
Westfire stoves have a 5-year guarantee against material faults and other
manufacturing defects in line with the following warranty terms. Your receipt
documents are the date of purchase The warranty will only apply if we have
received from you the duly completed registration card within 2 weeks of
purchase.
Your stove must have been purchased from an authorized Westfire Stoves dealer
whose name must be shown on the registration card.
Your stove must have been installed and serviced within 12 months of
installation by a HETAS or equivalent Regis- tired engineer This warranty
covers replacement or repair of the parts found to be defective but does not
cover the labor or carriage charges. Westfire Stoves reserve the right to
inspect any component prior to replacement. Westfire stoves reserve the right
to refuse to provide replacement parts in the event that the registration card
has not been completed and returned.
Please note that this is not transferable and is extended only to, and is
solely for, the benefit of the original purchaser of the stove and will
therefore only apply when the dated sales receipt as proof of purchase is
produced to Westfire Stoves.
WHAT IS NOT COVERED:
The warranty does not cover:
- Consumable service parts are repairs or replacements of parts, which are subject to normal wear and tear during the warranty period or parts that require replacement in connection with normal maintenance. Such parts include but are not limited to baffles, fire bars, grate assemblies, firebricks, glass, and glass assemblies, ashtrays, and sealing materials such as sealing rope. Consumable parts will require periodic replacement.
- Senotherm painted surfaces.
- Damage resulting from installation and usage other than as described in Westfire stoves´ installation and operation instructions, or if the installation does not conform to local building and fire and safety regulations.
- Defects or faults caused by local conditions such as draught problems and chimney defects.
- Damage resulting from overfiring the appliance – over-firing can be identified by warped plates and areas where the paint pigment has been burned off or by chipping, cracking, or bubbling (as further described in the operation manual).
- Damage is caused by the use of the wrong type of fuel.
- Damage caused by modifications or repairs other than as expressly authorized by Westfire Stoves or by the user or any other party other than Westfire stoves.
- Damage was made while the stove is in transit. (Any appliance so damaged must not be installed or operated as this may damage any claim you may have against the carrier/authorized dealer). Please contact the authorized Westfire stove dealer from whom you bought the stove.
- Damage arising where the stove has been used for commercial, business, or resale purposes nor shall we have any liability to you for any loss of profit, loss of business, business interruption, or loss of business opportunity.
- Parts of products for which any manufacturer other than Westfire stoves provides warranties.
- Removal and re-installation cost.
Products repaired or replaced under the warranty are covered only for the
remainder of the original warranty period.
Any claim under this warranty must in the first instance be submitted to the
authorized dealer from whom the stove was purchased. If the such dealer has
ceased trading or is no longer an authorized dealer please write to Westfire
Stoves, indicating the model number, size and serial number, the place,
price, and date the stove was purchased (including the original sales receipt)
the date it was installed and any other information which Westfire Stoves may
reasonably require.
The warranty does not affect your statutory rights and in particular, Westfire
Stoves does not seek to limit liability for death or personal injury caused by
Westfire Stove’s negligence or the negligence of its employees, agents or
subcontractors. Westfire Stoves will not in any circumstances (whether under
the warranty or otherwise) be responsible for loss or damage you suffer that
is not a foreseeable result of its breach of this warranty).
RE-INSTALLING BRICK SET
- Ensure the base grate is in position
- Place rear brick to the back of the stove ( holes uppermost)
- Fit side brick close to the door (slide under location point at top of the top)
- Fit second side brick (between rear brick and front side brick)
- Fit top turbulence baffle by securing baffle plate under at front and inserting a pin at rear.
- Fit the baffle by placing it on top of the rear brick and securing it with 2 steel pins into the side bricks.
SPARE PARTS
WF UNIQ 35 parts listing for most commonly used parts.
SERIES ONE
DESCRIPTION | CODE | COMMENTS |
---|---|---|
Brick set | WF35brickset | Consists of 2x side bricks, 1x rear brick, 1x |
lower baffle brick, 1 x upper baffle brick
Base Grate| WFONEBASEGRATE|
Ashpan| WF35ASHPAN|
Door| |
Door Rope Seal| WF35DRS|
Door Glass| WF35GLASS|
Tool| WF ONETWO TOOL|
Glove| WFglove|
Westlire 2436 WF 35.docx 22.11.2019 12:49:01
Detie PDF dokument er kin gyklgt, hvis er dgitalt sgneret mod OCES
ositalsgnaturen for Krn S.g Andersen. Te<noiogisk Institut. I Ns POI- document
is ctSy valid it Olga 11, sionoC with tro riCtS clio nal stcnatu re for Kim
Sig Andersen. Uansn I ochncloocal Institute.
WEST FIRE 2020 | WF35
POTTEMAGERVEJ 1 TELEFON +45 7482 0003
E-MAIL: SALES@VARDEOVNE.DK
WWW.WESTFIRE.DK
Der tages forbehold for trykfejl 17.12.2021