Forward
Thank you for purchasing a GODOX product
Dental ring f lash MF-R76S+ is a powerful macro f lash for close-up
photography, especially oral dental photography. It produces a flat, balanced
light that eliminates unwanted shadows by illuminating the teeth from every
direction, providing sharp and focused images of the patients’ teeth even when
in dark environment.
Main Features
- No vignetting and no shadows in macro shooting.
- Accurate power adjustment from 1/1 full power to 1/256 at l/3EV each stop.
- Equipped with 2.4G wireless transmission, workable as a transmitter or receiver unit in wireless flash group.
- Lithium battery power supply, up to 550 flash times in 1/l full power.
- Easy to install and suitable for camera lenses with a diameter of 49mm-77mm.
- 2 focus assist beams and l O levels of brightness adjustment.
- Simple user’s interface, convenient and comfortable operation.
Warning
Always keep this product dry.
Do not disassemble. Should repairs become necessary, this product must be sent
to an authorized maintenance center.
Keep out of reach of children.
Do not disassemble, hit, crush, or expose to fire. If severe swelling occurs,
do not continue to use.
Do not leave or store the flash unit if the ambient temperature reads over
50°C.
Do not fire the flash directly into the eyes (especially those of babies)
within short distances.
Otherwise visual impairment may occur.
Do not use the flash un it in the presence of flammable gases, chemicals and
other similar materials. Under certain circumstances. these materials may be
sensitive to the strong light emitted by this flash unit, which could cause a
fire or electromagnetic interference.
As this product is not waterproof, do not use in rain or damp conditions.
Name of Parts
Light Body
-
Flash Head
-
MODE Button
-
Focus Assist Beam Button (7 ~ 1 O level)
-
MENU/Lock Button
-
RATIO Button
-
Test Button
-
SET Button
-
Select Dial
-
Power Switch Button
-
Lock Ring
-
Hotshoe
-
Flash Tube A
-
Flash Tube B
-
Battery Remove Button
-
Controller
-
2.5mm Sync Cord Jack
-
Connecting Cable
-
Lithium Battery
-
Adapter Ring Connecting Port
-
Detaching Mount
-
Display
-
Type-C Port
Display
TTL Auto Flash Mode
M (Manual) Flash Mode
2.4G Wireless Transmission as a Transmitter Unit
M: Flash Group M
A: Flash Group A
B: Flash Group B
C: Flash Group C
2.4G Wireless Transmission as a Receiver Unit
RX: Receiver Flash Group (A, B, CJ
What’s Inside
Battery
- This product uses 7.2V/300DmAh lithium battery which has long runtime.
- It is safe and reliable. The inner circuit is against overcharge, over discharge, overcurrent, and short circuit.
Tips: Dental ring flash MF-R76S+ is compatible with GodoxVl lithium battery VB26 and ADl00Pro lithium batteryWBl00 (7.2V/2600mAh or7.2V/3200mAh)
Cautions
- Do not short circuit.
- Do not expose to rain or submerge in water. This battery is not water proof.
- Keep out of reach of children.
- Do not leave the battery charging for more than 24 hours.
- Store in dry, cool, ventilated places.
- Do not put aside or into fire.
- Dead batteries should be disposed according to local regulations.
- If the battery has not been used for over 3 months, please fully recharge the battery.
- If not in use for an extended period, please charge the battery to around 60% before storing.
Loading and Unloading the Battery
Installation of the Controller
Disassembly of the Controller
Loosening the Lock Ring
Rotate clockwise to loosen the lock ring and take down the controller.
Installation of the Ring Flash
Disassembly of the Ring Flash
Slightly pull out the remove buckle on the back, and then rotate to the right to remove the ring flash.
Power Switch
Toggle Power switch button to< ON> to power on, and< OFF> to power off.
TTL Flash Mode
M (Manual) Flash Mode
Short press the MODE button to switch to
There are 3 flash modes: flash tube A and B flash in different flash ratio,
only flash tube A or B flashes, flash tube A and B flash in the same flash
ratio.
1. Overall Flash Ratio Setting
Short press the Ratio button to make
Turn the select dial to adjust the output power from l/l full power to l/256
with an increment of 1/3 each stop.
Note: The minimum output is 1/64 when HSS (High Speed Sync) is turned on.
2. A:B Flash Output Setting
Short press the Ratio button to make
Short press the SET button to select group A output /group B output, turn the
select dial to adJust the group A output /group B output from l/l full power
to l/256 with an increment of 1/3 each stop.
3. Single Group Flash Output Setting
Short press the Ratio button to make
Short press the SET button to select group A output /group B output, turn the
select dial to adjust the group A output /group B output from l/l full power
to l/256 with an increment of 1/3 each stop.
Note: If group A outputs flash, then group Bis off.
Transmitter Unit Setting
Set the flash status as a transmitter unit in the menu (please refer to the
wireless setting).
Turn the select dial to switch group
M/A/B/C. Turn the SET button to select. then short press the MODE button to
switch to
TTL/Mi–. Turn the select dial in TTL mode to adjust the FEB value from -3 to
+3 with an increment of 1/3 each stop. Turn select dial in M mode to adjust
the output power from 1/1 full power to 1/256 with an increment of l /3 each
stop.
Note: TTL means TTL auto flash, M means manual flash, — means off.
The parameter values of A, B, C in the interface are parameter values of
receiver A, B, C. One transmitter unit can control four receiver units at
most, and the transmitter unit output is group M output.
The wireless channel of the transmitter unit should be set the same as the
receiver units in order to control them, please refer to the wireless setting.
Receiver Unit Setting
Set the flash status as a receiver unit in the menu (please refer to the wireless setting below).
Short press the SET button or turn the select dial to switch among A/B/C
A means the flash is set as receiver A unit.
B means the flash is set as receiver B unit.
C means the flash is set as receiver C unit.
The wireless channel of the transmitter unit should be set to the same channel as the receiver units, please refer to the wireless setting.
High Speed Sync
MF-R76S+ is capable of producing high-speed flashes synchronized with the maximum shutter speed of the camera, making it especially handy when taking pictures of the subject at soft light background.
- Short press the MENU/lock button to enter the menu settings.
- Turn the select dial to< SYNC>.
- Short press the SET button to enter setting.
- Turn the select dial to< **** >
- Short press the MENU/lock button to return to the main interface, the< ****> icon will be on the upper right corner.
Note: The minimum power of M (manual) flash is 1/64 when HSS (High Speed Sync) is on.
First Curtain Sync
First curtain flash refers to the flash fires at moment when the first curtain is fully opened, this function is suitable for shooting scenes in general situations.
- Short press the MENU/lock button to enter the menu settings.
- Turn the select dial to
. - Short press the SET button to enter setting.
- Turn the select dial to< >
- Short press the MENU/lock button to return to the main interface.
Focus Assist Beams
Short press the focus assist beam button to turn on or turn off the modeling
light.
Focus assist beam adjustment Turn on the focus assist beam, long press focus
assist beam button to enter the setting interface, then turn the select dial
to adjust in increments of 7-10 stops. After that, long press to exit.
Locking Function
Long press the MENU/lock button to lock or unlock the display.
Short press any button in the locked status won’t work, and this’s to avoid maloperation during shooting.
Note: After entering the menu interface, if you long press the MENU/lock button without any response, it does not work to lock.
Sync Cord Jack Trigger
The sync cord or trigger plug can be inserted into the 2.5mm sync port to fire the flash.
Over-Temperature Protection
To avoid overheating and deteriorating the flash head, do not fire more than
30 continuous flashes
in fast succession at 1/1 full power. After 30 continuous flashes, allow a
rest time of at least 10
minutes.
If you fire more than 30 continuous flashes and then fire more flashes in
short intervals, the inner overtemperature protection function may be
activated and< > is shown on the display. If this occurs, allow a rest time of
about 1 D minutes, and the flash unit will then return to normal.
Number of flashes that will activate over-temperature protection:
Number of flashes that will activate over-temperature protection in HSS mode:
Other Protections
Light Body Reset
Long press the focus assist beam button and MENU button until “RESET” icon appears, when the “RESET” icon disappears, it means that the reset is completed.
Menu Setting
Technical Data
All the above data are based on God ox testing standards.
Design and specifications may be subject to change without notice.
List of Compatible Sony Cameras
ILCE-60001, a9, A7R, A7RIII, DSC-RXlO, A71V, A7C, A7R5, A7RIV, A7M3, ZV-ElO, a6400, A7RII
Note:
- This table only lists the tested camera models, not all Sony series cameras. For the compatibility of other camera models, a self-test is recommended.
- Rights to modify this table are retained.
Practical Guide to Dental Photography
Extra Oral Views
Set up-positioning of Photographer
For the best result of extra oral views, the camera should be positioned parallel to the patient at a constant distance of approximately l .5m.
The camera aperture should be set to f/8. Autofocus can be used as manual focussing can be difficult when holding the camera in the portrait position. Autofocus is activated by moving the AF switch on the lens to the AF position.
Intra Oral Views
Intra oral views are typically taken whilst the patient is in the dental chair as this simplifies the positioning of the patient and photographer for some of the standard views. Make sure to keep the lens set to manual focus and follow the guidance for each view to set the focus distance and the aperture correctly. Using manual focus will ensure that photos taken at different stages of treatment can be easily compared to show progress.
Troubleshooting Guide
Please refer to the guide table below when problems occur.
Firmware Upgrade
- This product supports firmware upgrade through the Type-C USB port, please use Type-C USB connection line (sold separately).
- As the firmware upgrade needs the support of Godox G3 software, please download and install the “Godox G3 firmware upgrade software” before upgrading from our official website www.godox.com. Then, choose the related firmware file.
- Please refer to the latest electronic version of the instruction manual.
The Reason & Solution of Not Triggering in Godox 2.4G Wireless
-
Disturbed by the 2.4G signal in outer environment (e.g. wireless base station, 2.4G wifi router, Bluetooth, etc.)
➔ To adjust the channel CH setting on the flash trigger (add 70+ channels) and use the channel which is not disturbed. Or turn off the other 2.4G equipment in working. -
Please make sure that whether the flash has finished its recycle or caught up with the continuous shooting speed or not (the flash ready indicator is lighten) and the flash is not under the state of over-heat protection or other abnormal situation.
➔ Please downgrade the flash power output. If the flash is in TTL mode, please try to change it to M mode (a preflash is needed in TTL mode). -
Whether the distance between the flash trigger and the flash is too close or not (<0.Sm).
➔ Please turn on the “close distance wireless moden on the flash trigger.
➔ Please set the MENU- -DIST to 0-30m. -
Whether the flash trigger and the receiver end equipment are in the low battery states or not
➔ Please replace the battery.
Maintenance
Shut down the device immediately should abnormal operation be detected.
Avoid sudden impacts and the product should be dedusted regularly.
It is normal for the flash tube to be warm when in use. Avoid continuous
flashes if unnecessary.
Maintenance of the flash must be performed by our authorized maintenance
department which can provide original accessories.
This product, except consumables e.g. flash tube, is supported with a one-year
warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired
by professionals.
Changes made to the specifications or designs may not be reflected in this
manual.
FCC Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Any Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
The device has been evaluated to meet general RF exposure requirement.
The device can be used in portable exposure condition without restriction.
Warning
Operating frequency:2472.99MHz- 2464.49MHz
Declaration of Conformity
GODOX Photo Equipment Co.,Ltd. hereby declares that this equipment are in
compliance with the essential requirements and other relevant provisions of
Directive 2014/53/EU. In accordance with
Article 70(2) and Article 70(70), this product is allowed to be used in all EU
member states.
For more information of DoC, Please click this web
link:https://www.godox.com/DOC/Godox_MF-R76C_DOC.pdf.
The device complies with RF specifications when the device used at 0mm from your body.
Warranty
Dear customers, as this warranty card is an important certificate to apply for our maintenance service, please fill in the following form in coordination with the seller and safe-keep it. Thank you!
Applicable Products
The document applies to the products listed on the Product Maintenance Information (see below for further information). Other products or accessories (e.g. promotional items. giveaways and additional accessories attached, etc.) are not included in this warranty scope.
Warranty Period
The warranty period of products and accessories isimplemented according to the
relevant Product
Maintenance Information. The warranty period is calculated from the
day(purchase date) when the product is bought for the first time, And the
purchase date is considered as the date registered on the warranty card when
buying the product.
How to Get the Maintenance Service
If maintenance service is needed, you can directly contact the product distributor or authorized service institutions. You can also contact the Godox after-sale service call and we will offer you service. When applying for maintenance service, you should provide valid warranty card. If you cannot provide valid warranty card, we may offer you maintenance service once confirmed that the product or accessory is involved in the maintenance scope, but that shall not be considered as our obligation.
Inapplicable Case
The guarantee and service offered by this document are not applicable in the
following cases: @The
product or accessory has expired its warranty period;@ Breakage or damage
caused by inappropriate usage, maintenance or preservation, such as improper
packing, improper usage, improper plugging in/out external equipment, falling
off or squeezing by external force, contacting or exposing to the improper
temperature, solvent, acid, base, flooding and damp environments, etc;@
Breakage or damage caused by non-authorized institution or staff in the
process of installation, maintenance, alternation, addition and detachment;©
The original identifying information of product or accessory is modified,
alternated, or removed;@ No valid warranty card;@ Breakage or damage caused by
using illegally authorized, nonstandard or non-public released software;®
Breakage or damage caused by force majeure or accident;@ Breakage or damage
that could not be attributed to the product itself. Once met these situations
above, you should seek solutions from the related responsible parties and
Godox assumes no responsibility. The damage caused by parts, accessories and
software that beyond the warranty period or scope is not included in our
maintenance scope. The normal discoloration, abrasion and consumption are not
the breakage within the maintenance scope.
Maintenance and Service Support Information
The warranty period and service types of products are implemented according to the following Product Maintenance Information:
Godox After-sale Service
Call +86-755-29609320(8
GODOX Photo Equipment Co.,Ltd.
Add.: Building 2, Yaochuan Industrial Zone, Tangwei Community, Fuhai Street,
Bao’an District,
Shenzhen 518103, China Tel: +86-755-29609320(8062) Fax: +86-755-25723423
E-mail: godox@godox.com
godox.com
Made in China I 705-FR76SD-02
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>