selec MV Series Digital Voltmeter Instruction Manual

June 12, 2024
selec

selec-logo

selec MV Series Digital Voltmeter

selec-MV-Series-Digital-Voltmeter-product

Product Information

Product Name Description
MV15 AC MODEL, 3 Digit 7 segment LED display
MV205 AC MODEL, 3 Digit, LCD with Analog style bar graph

indication
MV305| AC MODEL, 3 Digit, LCD with Analog style bar graph
indication
MV507| AC MODEL, 3 Digit, LCD with Analog style bar graph
indication
MV207| AC MODEL, 3 Digit, LCD with Analog style bar graph
indication
MV2307| AC MODEL, 3 Digit, LCD with Analog style bar graph
indication
MV15-DC-20V| DC MODEL, Digital voltmeter
MV15-DC-200V| DC MODEL, Digital voltmeter
MV15-DC-200mV| DC MODEL, Digital voltmeter
MV15-DC-2V| DC MODEL, Digital voltmeter
MV15-AC-20/200V| AC MODEL (AUTO RANGING TYPE), Digital voltmeter
MV15-AC-200/2000mV| AC MODEL (AUTO RANGING TYPE), Digital voltmeter

Product Usage Instructions

To use the product, follow these instructions:

  1. Read the complete instructions prior to installation and operation of the unit.
  2. Ensure that the equipment is supplied with correct voltage.
  3. Make sure the power supply to the equipment is turned OFF before doing the wiring arrangement.
  4. Wiring shall be done strictly according to the terminal layout. Confirm that all connections are correct.
  5. Use lugged terminals for wiring.
  6. To reduce electromagnetic interference, use wires with proper shielding.
  7. Install the equipment in a location where it is not in close proximity to any heating sources, caustic vapors, oils, steam, or other unwanted process byproducts.

Operating Conditions:

  • Measurement Method: True RMS
  • Sampling Rate: 3 samples/second
  • Power Consumption: 5VA max.
  • Measuring Input Over Voltage: 1.5 x Vn continuous, 2 x Vn (3s)

Environmental Conditions:

  • Temperature: Up to 95% RH (non-condensing)
  • Altitude: Up to 2000 meters
  • Pollution Degree: II
  • Installation Category: III (600V)
  • Protection Class: II
  • Mounting: Panel mounting

Ordering Information:

Note: For CE and UL certified products, add “-CE” or “-CU” suffix to the order code.

For example: MV15-DC-20V-CU, MV305-CE

For 110V Supply, add “-110V” in the order code.

For example: MV15-DC-20V-110V-CU, MV305-110V-CE

Safety Precautions:

All safety-related codifications, symbols, and instructions that appear in this operating manual or on the equipment must be strictly followed to ensure the safety of the operating personnel as well as the instrument.

If the equipment is not used in a manner specified by the manufacturer, it might impair the protection provided by the equipment.

Do not use the equipment if there is any mechanical damage.

SPECIFICATIONS

SPECIFICATIONS|
---|---
AC MODEL
Product Name| MV15| MV205| MV305| MV507| MV207| MV2307

3 Ø Digital voltmeter with Selector switch

Description| 1 Ø Digital voltmeter
Display| 3 Digit 7 segment LED display                     3 Digit, LCD with Analog style bar graph indication

0 to 516V                                                    0 to 300V (L-N)

0 to 516V (L-L)

50 to 480V AC

50 / 60Hz

516V

“Or” for input > 516V 1M (±5%)

1V

Display range
Input range
Input Frequency
Max continuous Input range
Over range indication
Input impedance
Resolution
Electrical connection| 1 Ø – 2 wire

240V AC (± 20%), 50 / 60Hz ; 110V AC (± 20%), 60Hz

| 3 Ø-4wire, 3 Ø-3wire


206gm

Supply Voltage(Vn)
Weight| 170gm| 180gm| 180gm| 165gm| 194gm|
CE and UL Certification| YES| YES| CE ONLY| YES| YES| YES
DC MODEL| AC MODEL ( AUTO RANGING TYPE )
---|---
Product Name| MV15-DC-20V| MV15-DC-200V| MV15-DC- 200mV| MV15-DC-2V| MV15-AC-20/200V| MV15-AC-200/2000mV
Description| Digital voltmeter

3 ½ digit 7 Segment LED Display

Display
Display range| -19.99V to

+19.99V

| -199.9V to

+199.9V

| -199.9mV to

+199.9mV

| -1999mV to

+1999mV

| 0 to 19.99/199.9V| 0 to 199.9/1999mV
Input range| 0 to ±20V| 0 to ±200V| 0 to ±200mV| 0 to ±2000mV| 0 to 20/200V| 0 to 200/2000mV
Input Frequency| **| 50 / 60Hz
Max continuous Input range**| ±19.99V| ±199.9V| ±199.9mV| ±1999mV|


19.99/199.9V

| ****

199.9/1999mV

Over range Indication| “Or” for input

±19.99V

| “Or” for input

±199.9V

| “Or” for input

±199.9mV

| “Or” for input

±1999mV

| “Or” for input

199.9V

| “Or” for input

1999mV

Resolution| 0.01| 0.1| 1| 0.01/0.1| 0.1/1
Electrical connection| 1 Ø – 2 wire

240V AC (± 10%), 50 / 60Hz ; 110V AC (± 10%), 60Hz

Supply Voltage(Vn)
Weight| 170gm| 170gm| 170gm| 170gm| 170gm| 170gm
CE and UL Certification| YES| YES| YES| YES| YES| YES

  • Accuracy : ±0.5% of full scale over rated operating conditions
  • Measurement Method: True RMS
  • Sampling Rate : 3 samples / second
  • Power consumption : 5VAmax.
  • Measuring input over : 1.5 x Vn continuous, 2 x Vn (3s)

voltage
Environmental Conditions

  • Temperature : Operating: -10°C to 55°C
  • Storage : -20°C to 75°C
  • Humidity : Up to 95% RH(non condensing)
  • Altitude Up to 2000 meters
  • Pollution degree : II

Installation Category : III (600V)
Protection Class : II
Mounting : Panel mounting

Ordering Information
Note : For CE and UL certified product, Add-CE ; -CU suffix to order code.
For example MV15-DC-20V-CU ; MV305-CE
For 110V Supply add -110V in order code
For example MV15-DC-20V-110V-CU ; MV305-110V-CE.

SAFETY PRECAUTIONS

All safety related codifications, symbols and instructions that appear in this operating manual or on the equipment must be strictly followed to ensure the safety of the operating personnel as well as the instrument.
If the equipment is not used in a manner specified by themanufacturer it might impair the protection provided by the equipment.
Do not use the equipment if there is any mechanical damage.
Ensure that the equipment is supplied with correct voltage.

  1. Read complete instructions prior to installation and operation of the unit.
  2. Risk of electric shock.
  3. The equipment in its installed state must not come in close proximity to any heating sources, caustic vapors, oils, steam, or other unwanted process by products.

WIRING GUIDELINES

  1. To prevent the risk of electric shock, power supply to the equipment must be kept OFF while doing the wiring arrangement.
  2. Wiring shall be done strictly according to the terminal layout. Confirm that all connections are correct.
  3. Use lugged terminals.
  4. To reduce electromagnetic interference use of wires with adequate ratings and twists of the same in equal size shall be made with shortest connections.
  5. Layout of connecting cables shall be away from any internal EMI source.
  6. Cable used for connection to power source, must have a 2 2 0 crosssectionof 0.5mm to 2.5mm (20 to 14AWG; 75 C(min)). Thesewires shall have current carryingcapacityof 6A.
  7. Copper cable should be used (Stranded or Single core cable)
  8. Before attempting work on device, ensure absence of voltages using appropriate voltage detection device.

INSTALLATION GUIDELINES

CAUTION :

  1. This equipment, being built-in-type, normally becomes part of main control panel and in such case the terminals donot remain accessible to the end user after installation and internal wiring.
  2. Conductors must not come in contact with the internal circuitry of the equipment or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.
  3. Circuit breaker or mains switch must be installed between power source and supply terminals to facilitate power ‘ON’ or ‘OFF’ function. However this switch or breaker must be installed in a convenient position normally accessible to the operator.
  4. Before disconnecting the secondary of the external current transformer from the equipment, make sure that the current transformer is short circuited to avoid risk of electrical shock and injury.
  5. The equipment shall not be installed in environmental conditions other than those mentioned in this manual.
  6. The equipment does not have a built-in-type fuse Installation of external fuse of rating 275V AC / 0.5Amp for electrical circuitry / battery is highly recommended.

MECHANICAL INSTALLATION
For installing the meter

  1. Prepare the panel cutout with proper dimensions as shownbelow.
  2. Push the meter into the panel cutout. Secure the meter in its place by pushing the clamp on the rear side. The clamps must be secured in diagonally opposite slots.
  3. For proper sealing, tighten the screws evenly with required torque.
    Terminal screw tightening torque :
    0.68 N-mto 0.79 -m (6.018 In-Lb to 6.992 In-Lb) Screw clamp tightening torque : 0.1N-m 0.885 Lb-inch)selec-MV-Series-Digital-Voltmeter-fig
1

MAINTENANCE

  1. The equipment should be cleaned regularly to avoid blockage of ventilating parts.
  2. Clean the equipment with a clean dry or damp cloth. Do not useany cleaning agent other than water.

TERMINAL CONNECTIONS

selec-MV-Series-Digital-Voltmeter-fig
2

WIRING DIAGRAM

selec-MV-Series-Digital-Voltmeter-fig
3selec-MV-Series-Digital-Voltmeter-fig
5

(Specifications subject to change as development is a continuous process.)

Selec Controls Pvt. Ltd., India

  • Factory Address : EL-27/1, Electronic Zone, TTC Industrial Area, MIDC, Mahape, Navi Mumbai – 400 710, INDIA.
  • Tel. No. : +91-22-28476443 / 1882
  • Fax No. : +91-22-28471733
  • Toll free : 1800 227 353
  • Website: www.selec.com
    Email: sales@selec.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals