SELEC MV334 Digital Voltmeter Instruction Manual

June 13, 2024
selec

SELEC-LOGO

SELEC MV334 Digital Voltmeter

SPECIFICATIONS

  • Display: 4 Digit 7 Segment LED Display
  • Wiring Input: 304W,303W, 102W
  • Rated Input voltage: 11 – 300V AC(L-N) 19 – 516V AC(L·L)
  • Frequency range: 50/60 Hz
  • Mu continuous 11P range: 120% of rated VP Voltage
  • Over-range Indication: ‘Or’ for input> 516V(L-L) ‘Or” for input> 300V(L-N)
  • Impedance: 1M (±5%)
  • PT Primary: 100V – 999kV
  • PT Secondary: 100V-500V (Programmable to any value)
  • Resolution: Auto resolution
  • Accuracy: ±0.5% of full Range
  • MNSuring Method: True RMS
  • Dlaplay Update T1me: 1 sec.
  • Power Conaumpllon: Lass than SVA
  • Awdlary Supply Voltage: 230V AC(:l:20%), 50l60Hz
  • Weight: 190gms
  • Mounting: Panel mounting
  • Environmental Condition:
  • Operating Temperature: o•c to 50″C
  • Operating Storage: -25″C to 70″C
  • Relative Humidity: 011<l% (non-<:ondenslng)
  • Pollution degree: II

SAFETY PRECAUTIONS

  • All safely ralallld codlftcat lona, symbol and lns1rUCllona 1hat appear In 1hla operating manual or on the equipment must be st~c:dy followed to ensure the safety of the operating personnel as well as the ln .. rumen.
  • If Iha equipment Is not used In a manner spaced by Iha manufacturer ft might impair the protection provided by the equipment.
  • Do not use Iha equipment.-,t 11here la any mechanical damage.
  • Ensure all the equipment is grappled with corT8CI I/Ollage.

CAUTiON

  1. Read complete Instructions prior 10 lnatalatlon and operation of the unit.
  2. RlakoflllClricahod<.
  3. The equipment In Ila Installed taste mutt nal comes In close proximity to any heating source, caustic vapors, olla, team or another unwanted process by-products.

CONFIGURATION

  • Use Akey to enter & exit from config. menu, for 5 sec.
  • Use key to go to next parameter.
  • Use key to edit the parameter & press same key for 2 sec. to save parameter.
  • Use key to increment parameter value.
  • To set the value of PT primary in kV, First edit the value and then press A key for 3 sec., Display will shift to kV with resolution 000.0kV & this process is same, to set the value of PT primary in V.

SELEC-MV334-Digital-Voltmeter-FIG-6

ONLINE PAGE DESCRIPTION

SELEC-MV334-Digital-Voltmeter-FIG-7

Note : • Marked pages are not available when the network selection is 3P3W. and 1 P2W respective phase parameter will be available.

AUTO MANUAL DESCRIPTION
Press key for 3sec. to switch in auto and manual mode.
SERIAL NUMBER DESCRIPTION
Press key for 10sec. to display 8 digit serial number only for 10sec. in two windows.

WIRING DIAGRAM WITH TERMINAL CONNECTIONS

SELEC-MV334-Digital-Voltmeter-FIG-8

(Specifications subject to change as development is a continuous process.)
Selec Controls Pvt. Ltd., India

  • Factory Address :
  • EL-27/1, Electronic Zone, TTC Industrial Area, MIDC, Mahape,
  • Navi Mumbai – 400 710, INDIA.
  • Tel. No. : +91-22-4148 419/430 | Fax No.: +91-22-28471733
  • Toll-free: 1800 227 353 (BSNL/MTNL Subscribers only)
  • Website: www.selec.com I Email: sales@selec.com.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals