TOTALCOOL TF-18 Portable 17L Compressor Fridge Freezer User Guide
- June 12, 2024
- TOTALCOOL
Table of Contents
TOTALCOOL TF-18 Portable 17L Compressor Fridge Freezer
Product Features
- 17L capacity
- Compatible with 12V/24V power sources
- LED display with temperature adjustment, mode switch, power switch, and TURBO button
- Main technical parameters:
Model| Volume| Voltage| Average Consumption| Input Power| Minimum Temperature|
Maximum Temperature| Dimensions (LxDxH)
---|---|---|---|---|---|---|---
TF-18| 17L| 12V/24V| 2.92A| 35W| -18°C| +10°C| 532x230x384mm
Product Usage Instructions
- Before using the appliance, check the inside surface. If the inside surface is cold, your appliance is working.
- Use the LED display for temperature adjustment, mode switch, power switch, and TURBO button functionalities.
- Using the appliance with a DC power source, it will automatically identify and apply DC12V or DC24V.
- To clean the appliance, wipe it with a cloth and switch it on.
- Please note that the display shows the set temperature and not the actual temperature.
- In case of troubleshooting, refer to the provided circuit diagram and follow the instructions for each problem:
Problem | Cause | Remedy |
---|---|---|
The compressor runs for 15 minutes and stops | The voltage is not in the normal | |
range | Switch off power and restart when power is normal | |
The compressor runs but the inner unit does not get cold | The refrigerant has | |
leaked | Contact your local dealer |
The inner unit is very cold and the compressor runs
continuously.| The system is blocked| Defrost the unit
The compressor does not run| A layer of ice is too thick in the unit| The door
should be opened as little as possible
The freezer is noisy| The condenser is not well-ventilated. The controller is
faulty| Select a well-ventilated place. Contact your local dealer.
+ and – are switched| The controller is faulty (the power indicator is not
on)| Rectify the issue by contacting your local dealer.
The TF18 is not standing properly| | Place the TF18 on a level surface.
The pipes are touching| | Contact your local dealer
Contact Totalcool Ltd for further assistance:
Company number: 09633704
Website:www.totalcool.co.uk
The appliance must be earthed and connected to a suitable 24 volt or 12 volt socket. The manufacturer and the seller do not accept responsibility for any damage due to incorrect electrical installation.
TEST-RUN
- DC input condition: The voltage range required is DC10.9V ~28V. If the power is not stable, the unit will not run. The unit will restart when the voltage is normal.
- Connect power and set the digital thermostat to -180C. 30 minutes later, open the door and check the inside surface. If the inside surface is cold, your appliance is working.
LED DISPLAY
- Failure indicator light
- Temperature adjustment button
- Temperature display
- Mode switch button
- Power switch
- TURBO button
OPERATION WITH DC12V/DC24V
- Connect the DC cable supplied with the TF-18 to a suitable DC socket outlet. The appliance will automatically identify and apply DC12V or DC24V.
- Use a socket of at least 120W for 12V DC.
- Press the “Up” or “Down” arrow buttons to set the temperature you require.
- In the Temperature window the set temperature will now show. The compressor will start up to lower the temperature in the TF-18 and it will stop once the set temperature is reached. It will not start again until the temperature has raised 5 ºC from the set temperature. Please note that it is always the set temperature that will show in the display.
- For faster cooling press the “TURBO” button. This function requires more power and is therefore recommended to use while the motor or generator is running. PPLLEEAASSEE NNOOTTEE!! The “TURBO” function never turns off automatically but must be turned off by pressing the “TURBO” button.
- To turn off the appliance, push the off button and remove the DC plug from the DC socket.
DEFROSTING
- When a layer of ice forms on the inner walls of over 5mm, a defrosting operation should be performed to improve the refrigerating efficiency.
- Disconnect power, remove all items and clean your TF-18. After defrosting, clean with a soft cloth and switch the appliance on.
- Note: Never remove ice with sharp objects.
MAINTENANCE AND REGULAR CLEANING
- Always disconnect the power supply before cleaning. Clean the inside of the cabinet whenever necessary.
- Dirt from the condenser should be cleaned by a qualified technician when necessary.
NOTES
- It is normal to hear gurgling sounds from the TF18. This is caused by the flow of refrigerant when each cooling cycle ends.
- The surface temperature of the compressor can be very warm when running.
- The noise emitted by the cooling fan on the condenser is normal.
MAIN TECHNICAL PARAMETER
Model | TF-18 |
---|---|
Volume | 17L |
Voltage | 12V/24V |
Average
consumption
| ****
2.92A
Input power| 35W
Mini temp| -18℃
Max temp| +10℃
Dimensions
LxDxH
| ****
W532x230x384mm
- If you set the temperature to, for example, -7ºC, the compressor will turn off when this temperature is reached. The compressor will start again when the temperature is risen to -2ºC to lower it to -7ºC again. Please take this in to consideration when you set the TF-18 to your desired temperature.
- Please note that the display shows the set temperature and not the actual temperature.
CIRCUIT DIAGRAM
TROUBLESHOOTING
Problem | Cause | Remedy |
---|
The compressor runs for
1~5 minutes and stops
| The voltage is not in the normal
range
| Switch off power and restart
when power is normal
The compressor runs but inner unit does not get cold| The refrigerant has leaked| ****
Contact your local dealer
The system is blocked
The inner unit is very cold and the compressor runs continuously.
| A layer of ice is too thick in
the unit
| Defrost
The door is being opened and
closed too frequently
| The door should be opened as
little as possible
The condenser is not
well-ventilated. The controller is faulty
| ****
Select a well-ventilated place
The compressor does not run
| “+” and “-” are switched| Rectify
The controller is faulty (the
power indicator is not on)
| Contact your local dealer
The freezer is noisy
| The TF18 is not stood
properly
| Place the TF18 on a level surface
The pipes are touching| Contact your local dealer
PARTS
TRANSPORT AND INSTALLATION
- When moving your TF18, the angle between the cabinet and the ground should not be less than 45°, in order to protect the compressor and refrigerating system.
- Keep your TF18 in a dry and well-ventilated place. Kees away from direct sunlight, heaters, and corrosive gases.
- The normal operation of the TF18 depends on the heat radiation of the condenser. For the initial use, the packing foam must be taken off and at least: 150mm of space must be left around the unit.
Disposal:
- Place the packaging material in the appropriate recycling waste bins wherever possible.
- If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for details about how to do this in accordance with the applicable disposal regulations.
- Total cool Ltd
- Company number: 09633704 United Kingdom
- www.totalcool.co.uk
Documents / Resources
|
TOTALCOOL TF-18 Portable 17L Compressor Fridge
Freezer
[pdf] User Guide
TF-18, Totalfreeze 18 Portable Fridge Freezer, TF-18 Portable 17L Compressor
Fridge Freezer, Portable 17L Compressor Fridge Freezer, 17L Compressor Fridge
Freezer, Compressor Fridge Freezer, Fridge Freezer, Fridge, Freezer
---|---