CHAUVET PROFESSIONAL REM1 SMD LED Video Panel User Guide

June 12, 2024
Chauvet Professional

CHAUVET PROFESSIONAL REM1 SMD LED Video Panel

  • Scan the QR code to access the product page, warranty terms, and the complete User Manual

CHAUVET-PROFESSIONAL-REM1-SMD-LED-Video-Panel-FIG-2

Safety Notes

These Safety Notes include important information about installation, use, and maintenance of the REM 1 and REM 1SQ.

CAUTION:

  • This product’s housing may be hot when operating. Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.

ALWAYS:

  • Use a safety cable when mounting this product overhead.
  • Connect this product to a grounded and protected circuit.

DO NOT:

  • Open this product. It contains no user-serviceable parts.
  • Leave any flammable material within 50 cm of this product while operating or connected to power.
  • Connect this product to a dimmer or rheostat.
  • Operate this product if the housing, lenses, or cables appear damaged.
  • Operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect it (IP30).
  • Operate this product at an altitude exceeding 5000m.
  • ONLY use the hanging/mounting bracket to carry this product.
  • The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
  • The maximum ambient temperature is 95°F (35 °C). Do not operate this product at higher temperatures.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • In the event of a serious operating problem, stop using immediately.

FCC Statement of Compliance

This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

The use of certain substances in electrical and electronic equipment is restricted with the EU. For further information, see directive 2011/65/EU.

What is Included

REM1

  • 1 case (4 REM1)
  • 1 Seetronic® PowerKON® power cable
  • 4 Seetronic® PowerKON® power linking cables

REM1SQ

  • 1 case (8 REM1SQ)
  • 1 Seetronic® PowerKON® power cable
  • 8 Seetronic® PowerKON® power linking cables
  • 4 Seetronic® etherKON® signal linking cables
  • 5 spare LED masks
  • User manual
  • 8 Seetronic® etherKON® signal linking cables
  • 5 spare LED masks
  • User manual

AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.

AC Plug

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Power Linking
It is possible to power link REM 1 and REM 1SQ products. See the table below for the current draw at each voltage and frequency:

REM1

 | 100 V, 60 Hz| 120 V, 60 Hz| 208 V, 60 Hz| 230 V, 50 Hz| 240 V, 50 Hz
---|---|---|---|---|---
Current Draw| 2.4 A| 2.0 A| 1.15 A| 1.04 A| 1.0 A

REM1SQ

 | 100 V, 60 Hz| 120 V, 60 Hz| 208 V, 60 Hz| 230 V, 50 Hz| 240 V, 50 Hz
---|---|---|---|---|---
Current Draw| 1.2 A| 1.0 A| 0.57 A| 0.52 A| 0.5 A

Never exceed 12 A on a single circuit. Power-linking cables can be purchased separately.

Mounting

Before mounting this product, read the Safety Notes. Use rig bars (REM- RB50CMIP or REM-RB100CMIP) from Chauvet, or the M10 threaded mounting holes on the product. Make sure the mounting devices are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to http://trusst.com/productcategory/truss-clamps.

Mounting Diagram

CHAUVET-PROFESSIONAL-REM1-SMD-LED-Video-Panel-FIG-1

  • Warning! The magnetic attachments are not load-bearing, and are intended for alignment assistance only. Do not release panel until the hanging hardware has been fully secured.
  • The M10 mounting points are not intended for hanging or suspending from a truss or other overhead structure.

Contact Us

Chauvet U.K.

Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U. K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet Professional User Manuals

Related Manuals