REED INSTRUMENTS R9230 Multi Field EMF Meter Instruction Manual
- June 13, 2024
- REED INSTRUMENTS
Table of Contents
REED INSTRUMENTS R9230 Multi Field EMF Meter
Product Information
The REED R9230 is a Multi-Field EMF Meter designed to measure RF strength, magnetic fields, and electric fields. It features a triple axis (X, Y, Z) RF, EMF, and ELF sensor and a 2.4 TFT LCD display for easy reading of measurements. The meter has a data hold function, Min/Max functions, and an audible alarm. It also has an auto shut-off feature after 10 minutes of inactivity and a low battery indicator.
The product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specifications. If a certificate of calibration is
required, please contact the nearest authorized REED distributor or authorized
Service Center. Please note that an additional fee for this service will
apply.
Specifications
- RF Strength Measuring Range:
- Accuracy:
- Resolution:
- Magnetic Field Measuring Range:
- Accuracy:
- Resolution:
- Electric Field Measuring Range:
- Accuracy:
- Resolution:
- General Specifications:
- Sensor Type: Triple axis (X, Y, Z) RF, EMF, and ELF sensor
- Display: 2.4 TFT LCD display
- Data Hold: Yes
- Min/Max Functions: Yes
- Audible Alarm: Yes
- Auto Shut-off: Yes (after 10 mins)
- Low Battery Indicator: Yes
- Power Supply:
- Product Certifications:
- Operating Temperature:
- Storage Temperature:
- Operating Humidity Range:
- Storage Humidity Range:
- Maximum Operating Altitude:
- Dimensions:
- Weight:
Product Usage Instructions
- Ensure that the meter is powered on and the batteries are fully charged.
- Select the desired field to measure – RF strength, magnetic field, or electric field.
- Hold the meter close to the source of the field to be measured.
- Read the measurement value displayed on the 2.4 TFT LCD display.
- To hold the current measurement value, press the “Data Hold” button.
- To view the minimum and maximum values recorded, use the “Min/Max” functions.
- If an audible alarm is required, activate it using the designated button.
- The meter will automatically shut off after 10 minutes of inactivity to conserve battery life.
- If the low battery indicator is displayed, replace the batteries with fresh ones.
Note: For any servicing or calibration needs, please contact an authorized REED service center.
Introduction
Thank you for purchasing your REED R9230, Multi-Field EMF Meter. Please read
the following instructions carefully before using your instrument. By
following the steps outlined in this manual your meter will provide years of
reliable service.
Product Quality
This product has been manufactured in an ISO9001 facility and has been
calibrated during the manufacturing process to meet stated product
specifications. If a certificate of calibration is required, please contact
the nearest authorized REED distributor or authorized Service Center. Please
note an additional fee for this service will apply.
Safety
- This meter measures electromagnetic fields. Do not use near medical devices such as pacemakers, hearing aids, or insulin pumps.
- Do not use in explosive or flammable environments.
- Keep the meter away from water and other liquids to prevent damage to the device and electrical shock.
- Read the instruction manual carefully before use.
- Never attempt to repair or modify your instrument. Dismantling your product, other than for the purpose of replacing batteries, may cause damage that will not be covered under the manufacturer’s warranty. Servicing should only be provided by an authorized service center.
Features
- Magnetic field, electric field, and radio frequency (RF) strength measurements
- 2.4″(50.8mm) (240 x 320 pixels) color TFT display
- Triple axis (X, Y, Z) RF, EMF and ELF sensor
- Audible alarm
- Data Hold and Min/Max functions
- Low battery indicator and auto shut-off
Included
- R9230 Multi-Field EMF Meter
- Batteries
Specifications
RF Strength
- Measuring Range: 30.0mV/m to 11.00V/m 0.02 to 32.0uW/cm² 2.3μW/m² to 320.9mW/m² 0.07 to 29.1mA/m
- Accuracy: ±1dB at 1V/m and 900MHz
- Resolution: 0.01, 0.1mV/m / 0.01V/m 0.01, 0.1μW/cm² 0.1, 1μW/m² / 0.1mW/m²0.01, 0.1mA/m
Mag netic Field
- Measuring Range: 200 to 2000mG 20 to 200μT
- Accuracy: ±12% rdg +5 dgt
- Resolution: 0.01μt, 0.1μT 0.1mG, 1mG
Electric Field
- Measuring Range: 50V/m to 2000V/m
- Accuracy: ±10% rdg + 60 dgt
- Resolution: 1V/m
General Specifications
- Sensor Type: Triple axis (X, Y, Z) RF, EMF and ELF sensor
- Display: 2.4″ TFT LCD display
- Data Hold: Yes
- Min/Max Functions: Yes
- Audible Alarm: Yes
- Auto Shut-off: Yes (after 10 mins)
- Low Battery Indicator: Yes
- Power Supply: 3 x AAA
- Product Certifications: CE
- Operating Temperature: 32 to 122°F (0 to 50°C)
- Storage Temperature: 14 to 140°F (-10 to 60°C)
- Operating Humidity Range: <80%
- Storage Humidity Range: <70%
- Maximum Operating Altitude: 6561′ (2000m)
- Dimensions: 4.2 x 2.4 x 1.0″ (107 x 60 x 25mm)
- Weight: 0.2lbs (106g)
Instrument Description
- LCD Display
- POWER Button
- DATA HOLD Button
- UP/SET Button
- DOWN Button
- RECORD/ENTER Button
- RF Detector
- Electric Field Detector
- Wrist Strap
- Battery Cover Screw
- Battery Compartment Cover
- Tripod Mounting Screw
- ELF Detector
Display Description
-
Low Battery Indicator
-
XYZ Axes Values
-
Electric Field Graph
-
RF Strength Graph
-
RF Strength Measurement Value
-
RF Strength Alert Level Indicator
-
Electric Field Measurement Value
-
Electric Field Alert Level Indicator
-
Magnetic Field Measurement Value
-
Magnetic Field Alert Level Indicator
-
Audible Alarm Indicator
-
LCD Brightness
Level Indicator -
Auto Power Off Indicator
Color Coded Alert Level Table (for reference purpose only)
Alert Level| Magnetic Fields| Electrical Fields| RF
Strength| Bar Color
---|---|---|---|---
LOW| <10.0mG| <499V/m| <10.0mW/m2| Green
MEDIUM| ≧10.0mG| ≧499V/m| ≧10.0mW/m2| Yellow
HIGH| ≧100.0mG| ≧999V/m| ≧99.9mW/m2| Red
Note: Audible Alarm is triggered when readings enter the red region.
Operating Instructions
Power ON/OFF
To turn the meter ON or OFF press and hold the POWER button for approx. 2
seconds.
Electric Field Measurements
The R9230 measures the electric field (Electrical Power) in the atmosphere of
the sensor’s surroundings.
- Hold the meter at the bottom and at arm’s length.
- Perform all tests according to the indicated direction of the electric field sensor. (Fig. 1).
- Hold the meter steady during measurement.
- The LCD will simultaneously Fig.1 display the electric field measurement, the Electric Field historical graph and alert level indicator based on the detected value.
Magnetic Field Measurements
Point the front section of the meter toward the desired electromagnetic field
to take a measurement.
Due to environment related magnetic field factors, this electromagnetic field
(EMF) meter may display a reading of under 0.50mG prior to testing. This is
caused by the magnetic noise in the environment, rather than meter failure.
If the sensor is moved quickly, excessive field strength values will be displayed which do not reflect the actual field conditions. This effect is caused by electrostatic charges.
1. Hold the meter at arm’s length.
2. Point the front face of the meter toward the source of power.
3. Hold the meter steady during measurement.
4. Make several measurements at various locations. This is particularly
important if the field conditions are unknown.
5. The LCD will simultaneously display the electromagnetic field readings of
individual (XYZ), the combined Magnetic field readings in the units of
measurement selected by the user (See Setting Magnetic Unit of Measurement for
additional details) and alert level indicator based on the measured value.
RF Strength Measurements
Point the front face of the meter toward the desired RF field to take a
measurement.
- Hold the meter at arm’s length.
- Point the front face of the meter toward the source of power. Fig. 2.
- Hold the meter steady during the measurement.
- The LCD will simultaneously display the RF strength measurement in the units of measurement selected by the user (See Setting the RF Strength Unit of Measurement for additional details), the RF strength historical graph and alert level indicator based on the measured value.
Data Hold
- While taking a measurement, press the HOLD button to freeze the current measurements on the display.
- While in this mode a “HOLD” symbol will appear on the display.
- Press the button again to resume normal operation.
Note: When the DATA HOLD feature is active all buttons except the POWER button are disabled.
Recording Maximum and Minimum Readings
-
Press the REC button to enter recording mode as indicated by
“REC” on the LCD. The meter will now begin recording maximum and minimum readings. -
While in recording mode:
- Press the REC button once and the maximum values will appear on the display as indicated by “REC MAX”.
- Press the REC button again and the minimum values will appear on the display as indicated by “REC MIN”.
- To exit recording mode and resume normal operation, press and hold the REC button for two seconds.
When in recording mode the POWER button is disabled and the meter cannot be turned off.
Setting LCD Brightness
After powering the meter ON, press the POWER button to set the LCD brightness
level as indicated by (Low, Medium, and High) on the meter display.
Setup Mode
- Press and hold the SET button for 2 seconds to enter Setup Mode.
- Use the and arrows to scroll through the following parameters:
Parameter| Description
---|---
POWER OFF| Enable or disable the auto-power off function
BUZZER| Turn the beeper on or off
LF UNIT| Setting the Magnetic unit of Measurement
EMF UNIT| Setting the RF Strength Unit of Measurement - Once the appropriate parameter has been selected, follow the instructions below.
Enabling/Disabling Auto Power OFF (POWER OFF)
- Press the REC button when “POWER OFF” appears on the LCD.
- Press the and buttons to select between YES (enabled) or NO (disabled). With the Auto Power OFF feature enabled, the meter will automatically switch OFF after 10 minutes of inactivity to preserve battery life.
- Press the REC button to confirm selection and return to the Setup Mode screen.
Note: At any time, you can press the POWER button to exit the Setup Mode and resume normal operation.
Enabling/Disabling the Beeper (BUZZER)
- Press the REC button when “BUZZER” appears on the LCD.
- Press the and buttons to select between YES (enabled) or NO (disabled).
- Press the REC button to confirm selection and return to the Setup Mode screen.
Note: At any time, you can press the POWER button to exit the Setup Mode and resume normal operation.
Setting the Magnetic unit of Measurement (LF UNIT)
- Press the REC button when “LF UNIT” appears on the LCD.
- Press the and buttons to select between uT (micro Tesla) and mG (Milli Gauss).
- Press the REC button to confirm selection and return to the Setup Mode screen.
Note: At any time, you can press the POWER button to exit the Setup Mode and resume normal operation.
Setting the RF Strength Unit of Measurement (EMF UNIT)
- Press the REC button when “EMF UNIT” appears on the LCD.
- Press the and buttons to select between “mW/m^2 – μW/m^2”, “μW/cm^2”, “V/m – mV/m”, “mA/m”.
- Press the REC button to confirm selection and return to the Setup Mode screen.
Note: At any time, you can press the POWER button to exit the Setup
Mode and resume normal operation.
Battery Replacement
When the low battery icon appears on the LCD, the battery needs to be
replaced.
- Use a Flat head screwdriver to remove the battery cover.
- Install (or replace) the 3 x AAA batteries.
- Secure the battery cover back into place using the Flat head screwdriver.
Applications
- Home Appliances
- Power Lines
- Electrical Appliances
- Industrial Devices
- Mobile/Cell Phones
- Base Stations
Accessories
CA-52A Small Soft Carrying Case
R1500 Tripod
Don’t see your part listed here? For a complete list of all accessories and
replacement parts visit your product page on
www.REEDInstruments.com.
Product Care
To keep your instrument in good working order we recommend the following:
- Store your product in a clean, dry place.
- Change the battery as needed.
- If your instrument isn’t being used for a period of one month or longer please remove the battery.
- Clean your product and accessories with biodegradable cleaner. Do not spray the cleaner directly on the instrument. Use on external parts only.
Product Warranty
REED Instruments guarantees this instrument to be free of defects in material or workmanship for a period of one (1) year from date of shipment. During the warranty period, REED Instruments will repair or replace, at no charge, products or parts of a product that proves to be defective because of improper material or workmanship, under normal use and maintenance. REED Instruments total liability is limited to repair or replacement of the product. REED Instruments shall not be liable for damages to goods, property, or persons due to improper use or through attempts to utilize the instrument under conditions which exceed the designed capabilities. In order to begin the warranty service process, please contact us by phone at 1-877-849-2127 or by email at info@reedinstruments.com to discuss the claim and determine the appropriate steps to process the warranty.
Product Disposal and Recycling
Please follow local laws and regulations when disposing or recycling your instrument. Your product contains electronic components and must be disposed of separately from standard waste products.
Product Support
If you have any questions on your product, please contact your authorized REED
distributor or REED Instruments Customer Service by phone at
1-877-849-2127 or by email at
info@reedinstruments.com.
Please visit www.REEDInstruments.com for the most up-to-date manuals, datasheets, product guides and software.
Product specifications subject to change without notice.
All rights reserved. Any unauthorized copying or reproduction of this manual
is strictly prohibited without prior written permission from REED Instruments.
Over 200 portable test and measurement instruments
Access our Product Catalog