CHAUVET PROFESSIONAL REM 3IP Hybrid Video Wall Solution User Guide
- June 13, 2024
- Chauvet Professional
Table of Contents
CHAUVET PROFESSIONAL REM 3IP Hybrid Video Wall Solution
Product Information
The REM 3IP and REM 3IPSQ are electrical devices that comply with Part 15 Part B of the FCC rules. They have a Model ID of REM3IP and REM3IPSQ respectively. These devices come with a Quick Reference Guide available in English, Spanish (ES), French (FR), German (Deutsch), and Dutch (Nederlands). The product is designed to be powered by AC power and has specific current draw values for different voltages and frequencies. The REM 3IP and REM 3IPSQ can be power- linked using separate power-linking cables. Mounting theproduct can be done using rig bars or the M10 threaded mounting holes on the product.
Product Usage Instructions
- Scan the QR code provided in the user manual to access the product page, warranty terms, and the complete User Manual.
- Before using the product, read the Safety Notes in the user manual for important information about installation, use, and maintenance.
- Ensure that the AC plug is connected correctly, with the AC Live wire connected to the appropriate wire color based on your region (Black for U.S., Brown for Europe), the AC Neutral wire connected to the appropriate wire color (White for U.S., Blue for Europe), and the AC Ground wire connected to the Green/Yellow wire.
- To improve the lifespan of the product, it is recommended to completely disconnect it from power via breaker or by unplugging it during periods of non-use.
- If power linking is desired, refer to the table in the user manual for the current draw values at different voltages and frequencies. Ensure that the total current draw does not exceed 12 A on a single circuit. Power-linking cables can be purchased separately.
- When mounting the product, make sure to use rig bars (REM-RB50CMIP or REM-RB100CMIP) from Chauvet or utilize the M10 threaded mounting holes on the product. Ensure that the mounting devices used are capable of supporting the weight of the product. Refer to the mounting diagram in the user manual for proper alignment and placement.
- For Chauvet line of mounting clamps, visit http://trusst.com/productcategory/truss-clamps.
Safety Notes
These Safety Notes include important information about installation, use, and maintenance of the REM 3IP and REM 3IPSQ.
CAUTION:
- This product’s housing may be hot when operating. Mount this product in a location with adequate
- ventilation, at least 20 in (50 cm) from adjacent surfaces.
- When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid
- ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure,
- allow the product to fully acclimate to the surrounding environment before connecting it to power.
ALWAYS:
- Use a safety cable when mounting this product overhead.
- Connect this product to a grounded and protected circuit.
DO NOT:
- Open this product. It contains no user-serviceable parts.
- Leave any flammable material within 50 cm of this product while operating or connected to power.
- Connect this product to a dimmer or rheostat.
- Operate this product if the housing, lenses, or cables appear damaged.
- Submerge this product (IP65). Regular outdoor operation is fine.
- Operate this product at an altitude exceeding 5000m.
- ONLY use the hanging/mounting bracket to carry this product.
- The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
- The maximum ambient temperature is 95°F (35 °C). Do not operate this product at higher temperatures.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the
- product from power via breaker or by unplugging it.
- In the event of a serious operating problem, stop using immediately.
FCC Statement
FCC Statement of Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is
subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This equipment has been tested and found to comply with the limits for Class B
digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment
generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The use of certain substances in electrical and electronic equipment is restricted with the EU. For further information, see directive 2011/65/EU.
What is Included
REM3IP
- 1 case (REM3IP X4)
- 1 Seetronic® PowerKON® power cable
- 4 Seetronic® PowerKON® power linking cables
- 4 Seetronic® etherKON® signal linking cables
- 5 spare LED masks
- User manual
REM3IPSQ
- 1 case (REM3IPSQ X8)
- 1 Seetronic® PowerKON® power cable
- 8 Seetronic® PowerKON® power linking cables
- 8 Seetronic® etherKON® signal linking cables
- 5 spare LED masks
- User manual
AC Power
This product has an auto-ranging power supply that can work with an input
voltage range of 100-240 VAC, 50/60 Hz.
AC Plug
Connection| Wire (U.S.)| Wire (Europe)| Screw
Color
---|---|---|---
AC Live| Black| Brown| Yellow/Brass
AC Neutral| White| Blue| Silver
AC Ground| Green/Yellow| Green/Yellow| Green
To eliminate unnecessary wear and improve its lifespan, during periods of non-
use completely disconnect the product from power via breaker or by unplugging
it.
Power Linking
It is possible to power link REM 3IP and REM 31PSQ products. See the table
below for the current draw at each voltage and frequency:
REM3IP
| 100 V, 60 Hz| 120 V, 60 Hz| 208
V, 60 Hz| 230 V, 50 Hz| 240 V, 50
Hz
---|---|---|---|---|---
Current Draw| 3.0 A| 2.5 A| 1.44 A| 1.3 A| 1.25 A
REM3IPSQ
| 100 V, 60 Hz| 120 V, 60 Hz| 208
V, 60 Hz| 230 V, 50 Hz| 240 V, 50
Hz
---|---|---|---|---|---
Current Draw| 1.5 A| 1.25 A| 0.72 A| 0.65 A| 0.63 A
Never exceed 12 A on a single circuit. Power-linking cables can be purchased separately.
Mounting
Before mounting this product, read the Safety Notes. Use rig bars (REM-
RB50CMIP or REM-RB100CMIP) from Chauvet,
or the M10 threaded mounting holes on the product. Make sure the mounting
devices are capable of supporting the
weight of the product. For our Chauvet line of mounting clamps, go to
http://trusst.com/productcategory/truss-clamps
Mounting Diagram
- Warning! The magnetic attachments are not load-bearing and are intended for alignment assistance only. Do not release the panel until the hanging hardware has been fully secured.
- The M10 mounting points are not intended for hanging or suspending from a truss or other overhead structure.
REM 3IP and REM 3IPSQ QRG Rev. 2
Scan the QR code to access the product page, warranty terms, and the complete
User Manual
- Model ID: REM3IP
- Model ID: REM3IPSQ
Contact Us
General Information
Chauvet World Headquarters
- Address: 3360 Davie Rd.
- Davie, FL 33314
- Voice: 954-577-4455
- Fax: 954-929-5560
- Toll Free: 800-762-1084
Technical Support
- Voice : 844-393-7575
- Fax: 954-756-8015
- Email: chauvetcs@chauvetlighting.com.
- Website: www.chauvetprofessional.com.
Chauvet U.K.
- Address: Pod 1 EVO Park
- Little Oak Drive, Sherwood Park
- Nottinghamshire, NG15 0EB
- UK
- Voice: +44 (0) 1773 511115
- Fax: +44 (0) 1773 511110
- Email: UKtech@chauvetlighting.eu.
- Website: www.chauvetprofessional.eu.
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U. K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record. UL 1573 CSA C22.2 No. 166 E113093 REM 3IP and REM 31PSQ QRG Rev. 2
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>