ZKTeco V3L Lite SpeedFace Installation Guide
- June 13, 2024
- ZKTECO
Table of Contents
ZKTeco V3L Lite SpeedFace
Product Information
- Product Name : SpeedFace-V3L (Lite)
- Version : 1.0
- Manufacturer : ZKTeco
- Address : ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan, China.
- Phone : +86 769 – 82109991
- Fax : +86 755 – 89602394
- Website : www.zkteco.com
Installation Guide
Due to regular upgrades of systems and products, ZKTeco could not guarantee exact consistency between the actual product and the written information in this manual
Installation Environment: Please refer to the following recommendations for installation.
- INSTALL INDOORS ONLY
- AVOID INSTALLATION NEAR GLASS WINDOWS
- AVOID DIRECT SUNLIGHT AND EXPOSURE
- AVOID USE OF ANY HEAT SOURCE NEAR THE DEVICE
Installation on the Wall:
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the backplate on the wall using wall mounting screws.
- Attach the device to the backplate.
- Fasten the device to the backplate with a security screw.
Connection Guide
Exit Button, Door Sensor & Bell Connection:
Refer to the following wiring to connect the device:
Terminal Block | Connection |
---|---|
Power | In |
Lock | RXRX+ GND +12V NO COM NC |
Exit Button | BUT GND SEN BELLBELL+ |
Door Sensor | BUT GND SEN BELLBELL+ |
Power Connection: AC Adapter DC12V
Ethernet Connection:
Connect the device and the computer software over an Ethernet cable. Use the following IP address settings:
- ZKBioAccess Default IP address: 192.168.1.201 Subnet mask: 255.255.255.0
- IP address: 192.168.1.130 Subnet mask: 255.255.255.0
Click [COMM.] > [Ethernet] > [IP Address] to change the IP address and then click [OK]. Note: In LAN, the IP addresses of the server (PC) and the device must be in the same network segment while connecting to the software.
Lock Relay Connection:
The system supports Normally Opened Lock and Normally Closed Lock. Take NC
Lock as an example below:
Device not sharing power with the lock
Terminal Block | Connection |
---|---|
Power | DC12V DC12V |
Lock | GND +12V NO COM NC |
Download Center
Scan the QR Code to download the User Manual, Installation Guide, and Quick Start Guide.
How to connect the device
Refer to the following wiring to connect the device.
Terminal Block
Exit Button, Door Sensor & Bell Connection
**Power Connection
**
- Recommended AC adapter: 12V ± 10%, at least 1500mA.
- Use an AC adapter with a higher current rating to share power with the other devices
Ethernet Connection
Connect the device and the computer software over an Ethernet cable. As shown
in the example below:
Click [COMM.] > [Ethernet] > [IP Address] to change the IP address and then
click [OK].
Note : In LAN, the IP addresses of the server (PC) and the device must be
in the same network segment while connecting to the software
Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock. The NO LOCK (normally opened at power on) is connected with ‘NO’ and ‘COM’ terminals, and the NC LOCK (normally closed at power on) is connected with ‘NC’ and ‘COM’ terminals.
Take NC Lock as an example below:
Device not sharing power with the lock
Download Center
Scan the QR Code to download the User Manual, Installation Guide and Quick Start Guide.
ZKTeco Industrial Park, No. 32, Industrial Road, Tangxia Town, Dongguan,
China.
Phone : +86 769 – 82109991
Fax : +86 755 – 89602394
www.zkteco.com
Copyright © 2022 ZKTECO CO., LTD. All Rights Reserved.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>