Read all cautions and warnings prior to operation of this equipment.
Protection Against Fire
- Maintain a minimum of 2 feet distance from any type of flame.
- Do Not install the unit to close too a heat source.
- Make sure cables are properly secured away from movement.
- Maximum surface operating temperature is 125°F
- Unit must not be left on for long periods of time.
Protection Against Electrical Fire
- Disconnect power before servicing.
- For connection to main power supply proceed to page 5.
- This fixture must not be left on for long periods of time.
Protection Against Mechanical Hazards
- Use safety resumes when hanging unit.
- Use quality clamps or bolts when positioning unit
- Do not open, risk of electrical shock.
Ingress Protection
The IP rating is commonly expressed as IP (Ingress Protection) is followed by 2 numbers (i.e. 65) where the numbers define the fixture rating. The first number indicates the size of a particle that can enter the fixture.. The second number indicates the extent of protection against water entering the fixture. An IP66 rating in this fixture indicates that dust particles can not enter the fixture. And there is protection against water spray from entering the fixture from any direction.
What is Included
- 1pc Deco Tentacle
- 6pc Single Point Mounting Clips
- 1pc User Manual
Specifications
Part Numbers
Fixture
5050T– Deco Tentacle
Mechanical Specifications
IP Rating: IP65
Fastening System: 6 Mounting Clips (included) 3M Temporary Mounting Tape
Power Connection: 5 Conductor Cable
Housing: Silicone type material
Housing Type: Lensed flex unit
Curbving Type: Up & Down Curve (when light output is facing up)
Length: 16.5 feet (5030mm)
Cut table: Cut table every 7 LEDs, ~6.5” (166 mm)
LED Spacing: .93” inch (23.8mm)
Electrical Specifications
LED Type: SMD 5050 R,G,B,WW
LED Qty: 210
Each LED Watts: .45
Color Temp WW: 3014K
CRI: 83
Lumens (Single led): 44lm
Beam Angle: 31֯ Each LED
Power Input: 24V
Total Max Power: 96W
Drive Method: Constant Voltage
Main Power Connection
Caution!
- Deco Lighting fixtures are specifically designed to be used with a Deco Drivers.
- Connection points must not be exposed to moisture or liquids. Use IP Rated Connections rated for outdoor use.
- Maximum Cable distance of 100ft before voltage drop.
- Connect only 1 Deco Tentacle per Deco Driver output.
The occupation of the connection-cable is as follows:
COM | Voltage + | Black Cable |
---|---|---|
R | Red | Red Cable |
G | Green | Green Cable |
B | Blue | Blue Cable |
W | Warm White | White Cable |
DMX-512 Control
Deco Driver Info
Power Link | 1 Unit | Can connect 1 unit per output port |
---|---|---|
Ch Mode | Ch 4 & Ch7 | Use Ch4 or Ch7 Mode to control the unit |
Size & Weight
Cuttable Every 6.53 inches (166mm)
16.5 feet / 5030mm (+/- 30mm With Cable) Total Length
Fixture Size | 16’6″ (5060mm) x .80″ (20 mm) x 1.1″(23.8mm) |
---|---|
Fixture Packaged | 15″ X 15″ X 1.5″ |
Net Weight | 4.2lb |
Gross Weight | 4.8lb |
Cleaning and Maintenance
Installation Maintenance: The operator has to make sure that the unit is operating safely and has the installation and electronics checked by an expert every 2 years
The following points have to be considered during the inspection:
-
All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.
-
There must not be any deformations on the housing, fixation and installation spots.
-
The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be removed. -
Flex Tube must only be cleaned using soap and water
Rigging the Fixture
Caution!
- The installation must be carried out by an authorized dealer or trained professional.
- Unit may cause severe injures if you have doubts concerning the safety do not install.
- Unit is to be 24 inches away from flammable materials (decoration material)
When rigging a unit it is very important that you follow common safety procedures. Rigging requires extensive experience including but not limited to calculating working loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional structural rigger.
When rigging the unit always be secured with a secondary safety attachment. The installation location of the Fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any failures. Installation should be checked at least one time a year by a skilled person.
Accessories
CON-COL-DC5 (5PIN IP rated connection)
5050T-ACC-BRA (rubber brace)
Driver Compatibility
DECO Driver CV
DECO Driver CV3 DIN
DECO Driver CV4
DECO Driver IP
Customer Support
MEGA-LITE has a customer support line to provide set-up help and answer any questions should you encounter a problem. Please visit our website for any other related technical documents. For service-related issues, please contact our service department at service@mega.lighting.
Operating Hours: Monday – Friday 9AM – 6PM CST
Phone: 210-684-2600
Email: sales@mega.lighting
Manual Version
Please Visit www.mega.lighting for the most up to date manual version.
Mega Lite
18668 Highway 16N Helotes, Texas 78023 Ph
210-684-2600 Fax
210-855-6279
www.mega.lighting /
info@mega.lighting
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>