DIGTUS Professional DN-93603 Keystone Jack Instruction Manual
- June 13, 2024
- DIGTUS Professional
Table of Contents
DIGTUS Professional DN-93603 Keystone Jack
DIMENSION
ASSEMBLY INSTRUCTION
KEYSTONE MODULE (SHIELDED & UNSHIELDED)
Step 1:
S/FTP: REMOVE THE CABLE JACKET
Strip approximately 40 mm of the cable jacket and separate the wires into 4
pairs.
U/UTP: REMOVE THE CABLE JACKET
Strip approximately 40 mm of the cable jacket, cut off the plastic cross and
separate the wires into 4 pairs.
Step 2: WIRING CONFIGURATION
Insert the wires through the wire manager and lay them into the correct slots,
according to the wiring diagram on the wire manager.
Step 3: TRIM WIRES
Trim the wires flush with the wire manager. It is strongly recommended that
the tip of the wires protrude max. 0.15 – 0.20 mm.
Step 4: WIRE INJECTION
The numbers help you to find the right way to insert the wire manager onto the
IDC. Press the wire manager down onto the IDC.
Step 5: LOCKING
Close the outer cap by pushing down both sides until it clicks.
Step 6: S/FTP: GROUNDING, STRAIN RELIEF
Connect the drain wire/braid shield to the shielded shell housing and tie up
the cable tie and finish.
U/UTP: STRAIN RELIEF
Tie up the cable tie and finish.