hama 00185850 TS39H Outdoor Sensor for Weather Station Instruction Manual
- June 13, 2024
- Hama
Table of Contents
- Controls and displays
- Explanation of warning symbols and notes
- Package contents
- Safety instructions
- Getting started
- Installation
- Operation
- Care and maintenance
- Warranty disclaimer
- Technical data
- Declaration of Conformity
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
**hama 00185850 TS39H Outdoor Sensor for Weather Station Instruction Manual
**
Controls and displays
- Temperature indicator
- Air humidity indicator
- Celsius / Fahrenheit setting key
- Channel setting key
- Battery compartment
- Cut-out for wall mounting
Thank you for choosing a Hama product.
Take your time and read the following instructions and information completely.
Please keep these instructions in a safe place for future reference. If you
sell the device, please pass these operating instructions on to the new owner.
Explanation of warning symbols and notes
Warning
This symbol is used to indicate safety instructions or to draw your attention
to specific hazards and risks.
Note
This symbol is used to indicate additional information or important notes.
Package contents
- TS39H outdoor sensor
- These operating instructions
Safety instructions
- The product is intended for private, non-commercial use only.
- Do not operate the product outside the power limits specified in the technical data.
- Do not use the product in a damp environment and avoid splashing water.
- Do not use the product in the immediate vicinity of heaters, other heat sources or in direct sunlight.
- Do not use the product in areas in which electronic products are not permitted.
- Do not place the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the product’s functionality.
- Do not drop the product and do not expose it to any major shocks.
- Do not open the device or continue to operate it if it becomes damaged.
- Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
- Keep the packaging material out of the reach of children due to the risk of suffocation.
- Dispose of packaging material immediately in accordance with the locally applicable regulations.
- Do not modify the product in any way. Doing so voids the warranty.
- Protect the product from dirt, moisture and overheating and use it in dry environments only.
- As with all electrical products, this device should be kept out of the reach of children.
- Only use the article under moderate climatic conditions.
- Use the product only for the intended purpose.
Warning – Batteries
- When inserting batteries, note the correct polarity (+ and – markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
- Only use batteries (or rechargeable batteries) that match the specified type.
- Before you insert the batteries, clean the battery contacts and the polarity contacts.
- Do not allow children to change batteries without supervision.
- Do not mix old and new batteries, or batteries of different types or from different manufacturers.
- Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
- Do not short-circuit batteries.
- Do not charge batteries.
- Do not burn batteries.
- Keep batteries out of the reach of children.
- Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
- Remove spent batteries from the product and dispose of them without delay.
- Avoid storing, charging and using in extreme temperatures and at extremely low atmospheric pressures (such as at high altitudes).
Getting started
- Open the battery compartment (5) and insert two AA batteries observing the correct polarity.
- Inside the battery compartment, you will also find the channel setting switch (4) that allows you to switch between channels “CH1, CH2 and CH3”. Press the button (4) until the desired channel has been set. The display (1) shows CH1, CH2 or CH3.
- Then close the battery compartment cover.
Changing batteries
- Open the battery compartment (5), remove and dispose of the spent batteries and insert two new AA batteries observing the correct polarity. Then close the battery compartment cover.
Note
Please remember, during commissioning, to always insert the batteries into the
measuring station first and then into the base station.
Installation
Note – Installation
- We recommend initially positioning the base station and measuring station at the preferred setup locations without installing them and carrying out all the settings – as described in 6. Operation.
- Do not install the station(s) until the settings are correct and the radio connection is stable.
Note
- The range of the radio transmission between the measuring station and the base station is up to 30m in unobstructed areas. Before installing, make sure that the radio transmission is not influenced by interfering signals or obstacles such as buildings, trees, vehicles, high-voltage power lines, etc.
- Before final installation, make sure that there is sufficient reception between the desired installation locations.
- When installing the measuring station, take care to ensure this is positioned so that it is protected from direct sunlight and rain.
- The international standard height for measuring air temperature is 1.25 m (4 ft) above ground.
Warning
- Buy special or suitable installation material from a specialist dealer for wall-mounting.
- Ensure that you do not install any faulty or damaged parts.
- Never apply force during installation. These can damage the product.
- Before mounting, check that the wall you have chosen is suitable for the weight to be mounted. Also make sure that there are no electric, water, gas or other lines running through the wall at the mounting site.
- Do not mount the product above locations where persons might sit or stand.
- We recommend mounting the measuring station securely and firmly onto an outdoor wall.
- Secure the dowel, screw, nail, etc. in the wall provided.
- Hang the measuring station onto it using the cut-out (6) provided.
Operation
Connection to the measuring station
- Place both devices as close together as possible to connect the base station and the measuring station with each other.
- After the batteries are inserted, the base station automatically searches for a connection to the measuring station and carries out the initial setup routine.
- If the device does not connect automatically, the manual search process must be started on the base station.
Note
- Initial setup takes around 3 seconds.
- The radio symbol on the measuring station flashes during the connection attempt.
- Avoid any operation of the buttons during this time! Otherwise, errors and inaccuracies may occur in the values and their transmission.
- The process is finished as soon as the indoor and outdoor measurement data are displayed on the base station.
- The measured value is automatically updated by the base device about every 30 seconds.
- If the temperature value is outside of the measuring range, LLL.L (for temperatures below the measuring range) or HH.H (for temperatures above the measuring range) will be displayed in the temperature indicator.
Channel selection/additional measuring stations
Note
- When doing so, ensure the same channel setting on the base station and each measuring station. Suitable base stations can be found at www.hama.com
- The transmitter channel of the supplied measuring station can be changed/set (CH1, CH2, CH3).
- The measuring station is suitable for the following base stations: 186380, 186412
Low battery
Measuring station
If the batteries need to be replaced, the icon for the low battery level
appears next to the outside temperature indicator of the base device . Change
the battery immediately.
Note – Changing the batteries
- Be aware that, after every battery change on the measuring station or base station, the stations will need to be resynchronised.
- To do this, remove the batteries from the other station and re-insert them or change them completely if required.
Care and maintenance
- Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents.
- Ensure that no water is able to enter the product.
Warranty disclaimer
Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/mounting, improper use of the product or from failure to observe the operating instructions and/or safety notes.
Technical data
Measuring station
Power supply 3.0 V 2 x AA batteries
Measuring range Thermometers Hygrometer -20°C – +60°C / -4°F – 140°F /
20% – 95%
Measuring increments Temperature ambient humidity 0.1°C / 0.2°F 1%
Measuring cycle Thermometer/ Hygrometer CH1: 57 s CH2: 67 s CH3: 79 s
Hygrometer Yes
Thermometers Yes
Frequency 433 MHz
power transmitted 60 µW
Range ≤ 60 m
Declaration of Conformity
Hama GmbH & Co KG hereby declares that the radio equipment type [00185850] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following Internet address: www.hama.com->00185850 ->Downloads.
Maximum radio-frequency power transmitted 0.630 mW
References
Read User Manual Online (PDF format)