CORNING DMRUG2678 Digital Medium-Power Remote Unit Owner’s Manual
- June 13, 2024
- Corning
Table of Contents
CORNING DMRUG2678 Digital Medium-Power Remote Unit Owner's Manual
5.4.2.4 Other Info
5.5 DLRU Config
5.5.1 RU - > Overview &Alarm
Click RU to enter the Overview interface and view the current status of RU alarms (e.g., Link Alarm).
Each alarm is defined as follows:
Link Alarm
Digital HW ALM
Temperature Alarm
Low Transmission Alarm
Overflow Alarm
DC Voltage Lower Alarm
Over Power Consumption Alarm
Firmware Mismatch Alarm
Drag the scroll bar to view more information (e.g., Temperature) as shown in the figure below.
![Each alarm is defined as follows:
Link Alarm
Digital HW ALM
Temperature Alarm
Low Transmission Alarm
Overflow Alarm
DC Voltage Lower Alarm
Over Power Consumption Alarm
Firmware Mismatch Alarm](https://manuals.plus/wp-content/uploads/2023/08 /CORNING-DMRUG2678-Digital-Medium-Power-Remote-Unit-Fig-166.jpg)
5.5.2 RU Parameter config
5.5.2.1 RF info
Click RU RU1 to read various RF information of RU, as shown in the figure below:
5.5.2.2 Carrier info
5.5.2.3 OP info
The OP Info list box displays the current optical port connection status and information reading volume of the device, as shown in the figure below.
5.6 Downlink/Uplink Config
5.6.1 Downlink Output Power Config (Power Sharing Process)
Step 1. Set Carrier Info in Chapter 5.3.1.3, including the operator info, carrier info. The DL ATT can be set to default value in power sharing config.
Step 2. Set the power sharing parameters in chapter 5.3.1.4
-
Assign each operator’s power share (percentage).
-
Select the carrier’s power assignment mode for each operator (Density /Even).
Density mode: power assignment based on carrier bandwidth.
Even mode: power assignment based on the carrier number. -
Config MIMO 1 and MIMO 2 channel.
-
Select the calculate button to active the value, then the DL ATT value in Step 1 will be automatically calculated.
-
Select the ‘Power Share Lock’ button to lock the ATT config.
-
The system will automatically emit the output target power based on power sharing configuration if the DCU input power is within the operation range.
Step 3. Set RIU ATT to meet DCU input power range according to chapter 5.1.2
5.6.2 Uplink Gain Config
The Total Uplink Gain = ‐2dB ‐ RIU UL ATT ‐ DCU UL ATT ‐ RU UL ATT
Step 1. Config the RIU UL ATT according to chapter 5.1.2
Step 2. Config the DCU UL ATT according to chapter 5.2.2.2
Step 3. Config the RU UL ATT according to chapter 5.4.2.2
The range of each ATT is listed as below.
5.7 Case
Release Version
6. APPENDIX: LED Functionality and Color Definition
Corning Optical Communications LLC · 4200 Corning Place · Charlotte, NC 28216
USA
800-743-2675 · FAX:
828-325-5060 · International:
+1-828-901-5000 ·
www.corning.com/opcomm
Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2023 Corning Optical Communications. All rights reserved. LAN-3091-AEN / January 2023
Corning Optical Communications
User Manual I LAN-3091-AEN I Page 139
References
- 163.ru
- Новости Саратова - главные новости сегодня | 164.ru - новости Саратова
- Кинешемский городской новостной ресурс 168 часов - новости, события и происшествия в городе Кинешма и Ивановской области
- Продажа дверей в Москве: двери со склада магазина с установкой купить недорого
- Corning Optical Communications | Fiber Optic Connectivity Solutions | Corning
- Legal Notices | Corning.com