robustel R5020 Lite 5G Industrial Router User Manual

June 12, 2024
robustel

Robustel R5020 Lite Hardware Manual
R5020 Lite
Hardware Manual
Robustel R5020 Lite Hardware Manual
robustel R5020 Lite 5G Industrial Router
Version: 1.0.1
Date: Feb. 27, 2023
RT098_HM_R5020_Lite

Regulatory and Type Approval Information
Table 1: Toxic or Hazardous Substances or Elements with Defined Concentration Limits

Name of the Part Hazardous Substances
(Pb) (Hg)
(DEHP) (BBP)
Metal parts o
Circuit modules o

Cables and cable
assemblies| o| o| o| o| o| o| o| o| o| o
Plastic and polymeric parts| o| o| o| o| o| o| o| o| o| o
o: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is  below the limit requirement in RoHS2.0.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials for this part might exceed the limit requirement in RoHS2.0.
Indicates that it does not contain the toxic or hazardous substance.

Radio Specifications for Europe

RF technologies 3G, 4G, 5G, Wi-Fi
Cellular Frequency* 5G: NR SA/NSA: n1/n2/n3/n5/n7/n8/n12/n13/n14/n18/n20/n25/

n26/n28/n29/n30/n38/n40/n41/n48/n66/ n71/n75/n76/n77/n78/n79
4G: LTE FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B14/B17/B18/
B19/B20/B25/B26/B28/B29/B30/B32/B66/B71
LTE TDD: B34/B38/B39/B40/B41/B42/B43/B48
LAA: B46 (only supports 2 x 2 MIMO)
3G: WCDMA: B1/B2/B4/B5/B8/B19
Wi-Fi Frequency| 2.4 GHz: 2.412 – 2.472 GHz
5 GHz: 5.150 – 5.825 GHz
Max RF power| 23 dBm ± 2dB@NR, 23 dBm ± 2dB@LTE, 23 dBm ± 2dB@WCDMA, 18 dBm ± 2dB@Wi-Fi

  • May vary on difference models.
    Note: Operation of 5150 ~ 5250 MHz frequency range is restricted to indoor use only.
    Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
    This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s) and Part 15 of the FCC Rules. Operation is subject to the following two conditions:
    (1) This device may not cause interference.
    (2) This device must accept any interference, including interference that may cause undesired operation of the device.
    Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
    — Reorient or relocate the receiving antenna.
    — Increase the separation between the equipment and receiver.
    — Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
    — Consult the dealer or an experienced radio/TV technician for help.

FCC& IC Radiation Exposure Statement

This equipment complies with FCC and Canada radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.

Simplified EU Declaration of Conformity

We, Guangzhou Robustel Co., Ltd. are located at 501, Building #2, 63 Yongan Road, Huangpu District, Guangzhou, China, declare that this radio equipment complies with all applicable EU directives. The full text of the EU DoC is
available at the following internet address: www.robustel.com/certifications/

Safety Information

General
– The router generates radio frequency (RF) power. When using the router, care must be taken on safety issues related to RF interference as well as regulations of RF equipment.
– Do not use your router in aircraft, hospitals, petrol stations or in places where using cellular products is prohibited.
– Be sure that the router will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the router should be away from computers, office equipment, home appliance, etc.
– An external antenna must be connected to the router for proper operation. Only uses approved antenna with the router. Please contact authorized distributor on finding an approved antenna.
RF Exposure
– This device meets the official requirements for exposure to radio waves. This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by authorized agencies.
– The device must be used with a minimum separation of 20 cm from a person’s body to ensure compliance with RF exposure guidelines. Failure to observe these instructions could result in your RF exposure exceeding the applicable limits.
Note: Some airlines may permit the use of cellular phones while the aircraft is on the ground and the door is open. Router may be used at this time.
The symbol indicates that the product should not be mixed with general household waste but must be sent to separate collection facilities for recovery and recycling.
The symbol indicates that the product meets the requirements of the applicable EU directives.
The symbol indicates that the product meets the requirements of the relevant UK legislation.
Related download link
Find more product documents or tools at: www.robustel.com/en/documentations/

Technical Support
Tel: +86-20-82321505
Email: [email protected]
Web: www.robustel.com
Document History
Updates between document versions are cumulative. Therefore, the latest document version contains all updates made to previous versions.

Date| Firmware Version| Document Version| Change Description
---|---|---|---
Nov. 23, 2022| 5.0.0| 1.0.0| Initial release.
Feb 27, 2023| 5.0.0| 1.0.1| Optimized image display of mounting kit.

Overview

The R5020 Lite is Robustel’s new 5G capable router supporting global 5G, 4G and 3G bands. The R5020 Lite leverages our tried and tested high performance CPU platform and it is compatible with 3GPP Release 16.

Package Checklist

Before commencing installation ensure your package has the following components:robustel R5020 Lite 5G Industrial Router -
installation

Note: The accessories could be different on specific order.

Panel Layout (May Vary on Different Models)

robustel R5020 Lite 5G Industrial Router - Panel

Interface Descriptions

  1. LED Indicator
    Name| Color| Status| Description
    ---|---|---|---
    RUN| Green| Fast Blinking (250ms)| Router is preparing (system initialization)
    On, blinking (500ms)| Router starts operating
    Off| Router is powered off
    MDM| Green| On, solid| Link connection is working
    On, blinking| Data is sent and received
    Off| Link connection is not working
    USR| USR-OpenVPN| Green| On, solid| OpenVPN connection is established
    Off| OpenVPN connection is not established
    USR-IPsec| Green| On, solid| IPsec connection is established
    Off| IPsec connection is not established
    USR-SIM| Green| On, solid| Using primary SIM card 1
    On, blinking| Using backup SIM card 2
    Off| Using WAN link (no SIM card inserted)
    RSSI| Green| On, solid| 56 network: Reference Signal Received Power greater than -86 dBm (Strong signal) Non-5G network: Received Signal Strength Indication greater than -73 dBm (Strong signal)
    On, blinking (1s)| 5G network: Reference Signal Received Power -105 to -86 dBm (Moderate signal) Non-5G network: Received Signal Strength Indication -91 to -73 dBm (Moderate signal)
    Fast blinking| 56 network: Reference Signal Received Power -140 to -106 dBm (Weak signal) Non-5G network: Received Signal Strength Indication -111 to -93dBm (Weak signal)
    —| Off| No signal
    2.4G| Green| On, solid| 2.4 GHz Wi-Fi is enabled and working properly
    On, blinking| 2.4 GHz Wi-Fi is working normally and there is data sending and receiving
    Off| 2.4 GHz Wi-Fi is disabled or not working properly
    56 Wi-Fi| Green| On, solid| 5 GHz Wi-Fi is enabled and working properly
    On, blinking| 5 GHz Wi-Fi is working normally and there is data sending and receiving
    Off| 5 GHz Wi-Fi is disabled or not working properly

Note: You can choose the display type of USR LED. For more details, please refer to
RT123_SM_RobustOS Software Manual, Services > Advanced > System >System Settings > User LED Type.

  1. PIN Description
    PIN| Description| Note
    ---|---|---
    1| V+| Power Supply Positive| Note:
  1. The input voltage is 12 to 36V DC.
    2| V-| Power Supply Negative
    3| TXD/A| RS232 Data Transmission/RS485_A, may vary on different model.|
    4| RXD/B| RS232 Data Receive/RS485_B, may vary on different model.
    5| GND| Signal Ground
  1. Reset Button
    Feature| Operation
    ---|---
    Reboot| Press and hold the RST button for 2~ 5 seconds under the operating status.
    Restore to default configuration| Press and hold the RST button for 5~10 seconds, the RUN LED starts blinking quickly, the router will restore to default configuration.
    Restore to factory default settings| Once the operation of restoring default configuration is performed twice within one minute, the router will restore to factory default settings.
    Note: The more details please refer to RT123_SM_RobustOS Software Manual, 2.3 Factory Reset.
  2. Ethernet Ports. There are two Ethernet ports on R5020 Lite, including ETH0, ETH1. The ETH0 on the router can be configured as a WAN port, while ETH1 can only be configured as a LAN port. By default, ETH0, ETH1 are lan0, and their IP are 192.168.0.1/255.255.255.0.
    Ethernet LED Indicator| Status| Description
    ---|---|---
    Link indicator (Yellow)| On, solid| Connection is established
    On, blinking| Data is being transferred
    Off| Connection is not established

Hardware Installation

  1. SIM Card Installation. Remove the SIM card cover to insert the SIM cards into the device, then screw up the cover.

  2. Antenna Installation. Rotate the antenna into the antenna connector accordingly.robustel R5020 Lite 5G Industrial Router - antenna

  3. Terminal Block Installation. Insert the 3-PIN terminal blocks into the interfaces connector, then can connect the devices or sensors to the gateway via corresponding interfaces.

  4. Mounting Kit Installation.
    – DIN Rail Mountingrobustel R5020 Lite 5G Industrial Router -
Mounting– Wall Mountingrobustel R5020 Lite 5G
Industrial Router - Wall Mounting

  5. Grounding the Device. Grounding will help to prevent the noise effect due to electromagnetic interference (EMI). Connect the device to the site ground wire by the grounding screw before powering on.robustel R5020 Lite 5G Industrial Router - electromagnetic

  6. Connect the router to the computer. Connect the Ethernet cable to any port labeled ETH0 or ETH1 of the router, and connect the other end of the cable to your computer.robustel R5020 Lite 5G Industrial Router - cable

Login to the Device

  1. Connect the router’s Ethernet port to a PC with a standard Ethernet cable.
  2. Before logging in, manually configure the PC with a static IP address on the same subnet as the gateway address, click and configure “Use the following IP address”.
  3. To enter the gateway’s web interface, type http://192.168.0.1 into the URL field of your Internet browser.
  4. Use login information shown in the product label when prompted for authentication.
  5. After logging in, the home page of the web interface is displayed, then you can view system information and perform configuration on the device.
  6. The automatic APN selection is ON by default, if need to specify your own APN, please go to the menu Interface->Link Manager->Link Setting->WWAN Settings to finish the specific setting.
  7. The more configuration details please refer to RT123_SM_RobustOS Software Manual. (END)

Support: [email protected]
Website: www.robustel.com
©2023 Guangzhou Robustel Co.,Ltd.
All rights reserved. Subject to change without notice.
RT098_HM_R5020_Lite

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

robustel User Manuals

Related Manuals