nVent HOFFMAN UU5040SP ULTRX Swing Out Panel Fits Instruction Manual
- June 12, 2024
- nVent HOFFMAN
Table of Contents
nVent HOFFMAN UU5040SP ULTRX Swing Out Panel Fits
Parts
- Place rubber bumpers onto brackets.
- Mount brackets to enclosure rails.
- Assemble latch assemblies; orient as shown.
- Mount pivot pins. Do not tighten top pin until panel is positioned onto the brackets.
- Assemble panel to brackets; use spacers to center panel vertically; tighten top pivot pin.
- Position and adjust panel to desired location inside the enclosure; tighten all screws to 20 in-Ibs.
NOTE: Panel may be hinged from either side.
Installation Instructions
Enclosure
| X| X
---|---|---
Minimum| Maximum
20x16x8| .98in / 24.9mm| 4.28in / 108.7mm
20x16x12| .98in / 24.9mm| 8.28in / 210.3mm
24x20x10| .98in / 24.9mm| 6.28in / 159.5mm
24x24x8| .98in / 24.9mm| 4.28in / 108.7mm
24x24x12| .98in / 24.9mm| 8.28in / 210.3mm
30x24x12| .98in / 24.9mm| 8.28in / 210.3mm
40x32x12| .98in / 24.9mm| 8.28in / 210.3mm
Contact
- PH: 763 422 2211
- Vent.com/HOFFMAN
References
Read User Manual Online (PDF format)