Victron Energy 150-35, BlueSolar MPPT Solar Charger User Manual

June 12, 2024
victron energy

Victron Energy 150-35, BlueSolar MPPT Solar Charger

Product Information – MPPT Solar Charger Manual

Introduction

The MPPT Solar Charger Manual provides instructions for the SmartSolar MPPT 150/35 and 150/45 models. It covers important information regarding battery voltage, PV voltage, current rating, monitoring, error codes, warranty, troubleshooting and support, technical specifications, and appendix.

Battery Voltage, PV Voltage, and Current Rating
Section 2.1 of the manual provides detailed information about battery voltage, PV voltage, and current rating. Please refer to this section for specific guidance on these parameters.

Monitoring

Section 7 of the manual focuses on monitoring the MPPT solar charger. It includes LED indications, error codes, monitoring via the VictronConnect App, and monitoring via a GX device and VRM.

  • 7.1 LED Indications: Learn about the various LED indicators and their meanings.
  • 7.2 Error Codes: Understand the error codes and troubleshoot accordingly.
  • 7.3 Monitoring via the VictronConnect App: Explore how to monitor the charger using the VictronConnect App, including the status screen, history screen, and error reporting.
  • 7.4 Monitoring via a GX device and VRM: Discover how to monitor the charger through a GX device and VRM.

Warranty

Section 8 of the manual provides information regarding the warranty for the MPPT solar charger. Please refer to this section for warranty-related details.

Troubleshooting and Support

Section 9 covers troubleshooting and support for the MPPT solar charger. It includes steps to take when the controller is not operational, visual check, battery supply check, operation issues, and an MPPT Solar Charger error code overview.

  • 9.1 The controller is not operational: Find troubleshooting steps when the controller is not functioning.
  • 9.8 Operation issues: Learn how to address issues related to power supply operation and DC to DC charger operation.
  • 9.9 MPPT Solar Charger error code overview: Understand the different error codes and their meanings.

Technical Specifications

Section 10 provides technical specifications for the MPPT solar charger, specifically for the 150/35 and 150/45 models. Refer to this section for detailed technical information.

Appendix

Section 11.1 of the manual contains the dimensions for the 100/35 and 150/45 models of the MPPT solar charger. Please consult this section for specific dimensions.

ENGLISH
MPPT solar charger manual
SmartSolar MPPT 150/35 & 150/45
Rev 04 – 02/2023
This manual is also available in HTML5.

Safety precautions

MPPT solar charger manual

1.1. General safety precautions
· Read this manual carefully. It contains important instructions that need to be followed during installation, operation and maintenance.
· Save these instructions for future reference on operation and maintenance
· Danger of battery explosion from sparking
· Danger of electric shock
· Install the product in a heatproof environment. Ensure therefore that there are no chemicals, plastic parts, curtains or other textiles, etc. in the immediate vicinity of the equipment.
· The product is not allowed to be mounted in a user accessible area.
· Ensure that the equipment is used under the correct operating conditions. Never operate it in a wet environment.
· Never use the product at sites where gas or dust explosions could occur.
· Ensure that there is always sufficient free space around the product for ventilation.
· Refer to the specifications provided by the manufacturer of the battery to ensure that the battery is suitable for use with this product. The battery manufacturer’s safety instructions should always be observed.
· Protect the solar modules from incident light during installation, e.g. cover them.
· Never touch uninsulated cable ends.
· Use only insulated tools.
· This product is designed and tested in accordance with international standards. The equipment should be used for the designated application only.
· Connections must always be made in the sequence described in the Installation [9] chapter of this manual.
· The installer of the product must provide a means for cable strain relief to prevent the transmission of stress to the connections.
· In addition to this manual, the system operation or service manual must include a battery maintenance manual applicable to the type of batteries used.
1.2. Wiring safety precautions
· Use flexible multi-stranded copper cable for the battery and PV connections.
· The diameter of the individual strand of the cable used should not exceed 0.4mm (0.016 inch) or have a surface area exceeding 0.125mm² (AWG26).
· The maximum operating temperature is 90°C (194°F).
·
· A 25mm² cable, for example, should have at least 196 strands (class 5 or higher stranding according to VDE 0295, IEC 60228 and BS6360). An AWG2 gauge cable should have at least 259/26 stranding (259 strands of AWG26). Example of suitable cable: class 5 “Tri-rated” cable (it has three approvals: American (UL), Canadian (CSA) and British (BS)).
· In case of thicker strands the contact area will be too small and the resulting high contact resistance will cause severe overheating, eventually resulting in fire. See below figure for examples of what cable to use and not to use.

Page 1

Safety precautions

MPPT solar charger manual
1.3. FCC Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: · Reorient or relocate the receiving antenna. · Increase the separation between the equipment and receiver. · Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. · Consult the dealer or an experienced radio/TV technician for help. This device contains a transmitter with FCC ID: SH6MDBT42Q.

Page 2

Safety precautions

MPPT solar charger manual

2. Introduction

The Victron Energy SmartSolar charge controller is an ultra fast Maximum Power Point Tracking (MPPT) solar charger with an outstanding conversion efficiency and is suitable for a wide range of battery and PV voltages.

2.1. Battery voltage, PV voltage and current rating
The solar charger can charge a lower nominal-voltage battery from a higher nominal voltage PV array. The controller will automatically adjust to the battery voltage and will charge the battery with a current up to its rated current.
The product name of the solar charger incorporates the maximum PV voltage and the maximum battery charge current.
For example: A 150/45 model has a maximum PV voltage of 150V and can charge the battery with a maximum of 45A.
The table below indicates the maximum PV voltage and maximum battery charge current of the solar chargers that are covered by this manual:

Solar charger model MPPT 150/35 MPPT 150/45

Maximum PV voltage 150V 150V

Maximum battery charge current 35A 45A

Suitable battery voltages 12, 24, 36 and 48V 12, 24, 36 and 48V

Page 3

Introduction

MPPT solar charger manual
3. Features
3.1. Automatic battery voltage detection
The solar charger automatically detects supported (e.g 12V, or 24V, or 48V) system voltage (battery voltage) on first power up. If a different system voltage is required at a later stage, or if the solar charger is connected to a 36V system, this can be manually configured in the solar charger settings.
3.2. Outstanding MPPT algorithm
Ultra fast MPP tracking The solar charger contains an ultra fast MPPT controller. This is especially beneficial when the solar light intensity is constantly changing, as is the case during cloudy weather. Because of the ultra fast MPPT controller, 30% more energy is harvested compared to solar chargers with a PWM controller and up to 10% more compared to slower MPPT controllers. Optimal solar yield The solar charger has an innovative tracking algorithm. It will always maximize energy harvest by locking to the optimum MPP (Maximum Power Point). If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP.
3.3. Outstanding conversion efficiency
The solar charger has an outstanding conversion efficiency. The maximum efficiency exceeds 98%. One of the benefits of the high efficiency is that the solar charger does not have a cooling fan and the maximum output current is guaranteed up to an ambient temperature of 40°C (104°F).
3.4. Extensive electronic protection
The solar charger is protected against over-temperature. The output is fully rated up to an ambient temperature of 40°C (104°F). Should the temperature further increase, the output current will be derated. The solar charger is equipped with PV reverse polarity protection and PV reverse current protection.
3.5. VictronConnect App
The VictronConnect App can be used to: · Monitor the solar charger and view real time solar and battery data. · Operate solar charger features. · Access up to 30 days historical data and error history. · Configure solar charger settings. · Update firmware.

Page 4

Screenshot of the VictronConnect App, showing real time data and historic data

Features

MPPT solar charger manual The VictronConnect App can be downloaded from app stores or from the Victron Energy downloads page. The app is available for the following platforms: · Android · Apple iOS (Note that USB is not supported, it is only possible to connect via Bluetooth) · MacOs · Windows (Note that Bluetooth is not supported, it is only possible to connect via USB)
Where to download the VictronConnect App from The VictronConnect App can connect to the solar charger via its built-in Bluetooth.

VictronConnect App connection via built-in Bluetooth The VictronConnect App can connect to the solar charger via the VE.Direct USB interface.
VictronConnect App connection via USB using a VE.Direct USB interface The VictronConnect App can connect remotely to the solar charger via a GX device connected to the same local network or via the internet using the VRM portal.

VictronConnect App connection via LAN or the internet (VRM portal) using a GX device (for example a Cerbo GX)
3.6. Display
There are a number of display options: · The VictronConnect App

Page 5

Features

MPPT solar charger manual
· A GX device · The VRM Portal (GX device or GlobalLink 520 needed) · The MPPT Control – an external display that connects to the VE.Direct port (the VE.Direct cable is not included with the MPPT
Control)
3.7. VE.Direct port
The VE.Direct port is used to communicate with the solar charger. It can be used for several purposes: · To connect to a monitoring device, such as a GX device or the GlobalLink. · To connect with the VictronConnect App. · For external control. Special cables or interfaces are needed to connect to this port: · VE.Direct cable – used to connect to a GX device or the GlobalLink. · VE.Direct to USB interface – used to connect via USB to the VictronConnect App. · VE.Direct Bluetooth Smart dongle – used to connect via Bluetooth to the VictronConnect App. · VE.Direct TX digital output cable – used for streetlight control or to create a virtual load output. · VE.Direct non inverting remote on/off cable – used to remotely switch the solar charger on or off.
3.8. Battery charging
3.8.1. Adaptive 3-stage battery charging
The solar charger is a 3-stage charger. The charge stages are: Bulk ­ Absorption ­ Float. Bulk During the bulk stage the solar charger delivers the maximum charge current, to rapidly charge the batteries. During this stage the battery voltage will slowly increase. Once the battery voltage has reached the set absorption voltage, the bulk stage stops and the absorption stage will commence. Absorption During the absorption stage the solar charger has switched to constant voltage mode. The current flowing to the battery will gradually decrease. Once the current has dropped below 2A (tail current), the absorption stage stops and the float stage will commence. When only shallow discharges occur the absorption time is kept short. This to prevent overcharging of the battery. But if the battery was deeply discharged, the absorption time is automatically increased, to make sure that the battery is fully recharged. Float During the float stage the voltage is reduced and batteries full charged state is maintained.
A storage stage is not needed for a solar charger, unlike is the case for an AC charger, since at night there is no solar power, so battery charging will stop.

3.8.2. Flexible charge algorithm
The VictronConnect App allows selection of 8 pre-set charge algorithms, or alternatively the charge algorithm is fully programmable. The charge voltages, stage duration and the charge current can be customized. In addition to this, 8 pre-programmed algorithms can be set with a rotary switch.
3.8.3. Equalization charging
Some lead-acid battery types need a periodic equalization charge. During equalization the charge voltage will be increased above the regular charge voltages to achieve cell balancing. If an equalization charge is required it can be enabled using the VictronConnect App.

Page 6

Features

MPPT solar charger manual
3.9. Temperature sensing
Temperature sensing allows for temperature compensated charging. The absorption and float charge voltages are adjusted based on either the battery temperature (accessory needed) or otherwise on the solar charger internal temperature. Temperature compensated battery charging is needed when charging lead-acid batteries in hot or cold environments. The temperature compensation can be enabled or disabled in the solar charger settings and the amount of compensation, the compensation coefficient (mV/°C), is adjustable.
3.9.1. Internal temperature sensor
The solar charger has a built-in internal temperature sensor. The internal temperature is used to set the temperature compensated charge voltages. For this, the internal temperature when the solar charger is “cold” is used. The solar charger is “cold” when there is only little current flowing into the battery. Be aware that this is only an estimation of the ambient and the battery temperature. Should a more accurate battery temperate be needed, consider using an external battery temperature sensor, see chapter External temperature and voltage sensor [7]. External temperature and voltage sensor [7]. The temperature compensation range is 6°C to 40°C (39°F to 104°F). The internal temperature sensor is also used to determine if the solar charger is overheated.
3.9.2. External temperature and voltage sensor
The Smart Battery Sense is a wireless battery voltage and temperature sensor and can be used with the solar charger. It measures the battery temperature and the battery voltage and sends this via Bluetooth to the solar charger. The solar charger uses the Smart Battery Sense measurements for: · Temperature compensated charging using the actual battery temperature, rather than the solar charger’s internal temperature.
An accurate battery temperature measurement will improve charging efficiency and prolong the life of lead-acid batteries.
· Voltage compensation. The charge voltage is increased to compensate in case there is a voltage drop over the battery cables during high current charging.
The solar charger communicates with the Smart Battery Sense via Bluetooth using a VE.Smart Network. For more detail on the VE.Smart network see the VE.Smart Networking manual. Alternatively, a VE.Smart Network that measures battery temperature and battery voltage, can also be set up between a solar charger and a BMV-712 Smart or SmartShunt battery monitor that has been equipped with a Temperature sensor for BMV, without the need for a Smart Battery Sense.
Note that a VE.Smart Network can only be set up if the solar charger is capable of Bluetooth communication, has Bluetooth enabled or is equipped with a VE.Direct Bluetooth Smart dongle.

Example of a VE.Smart Network of a Smart Battery Sense and a solar charger Page 7

Features

MPPT solar charger manual
3.10. Voltage sensing
An optional Smart Battery Sense or battery monitor measures the battery terminal voltage and sends this via Bluetooth using the VE.Smart [28] network to the solar charger. If the battery voltage is less than the solar charge voltage, the solar charger will increase its charge voltage to compensate for voltage losses.
3.11. Remote on/off
A virtual remote on/off terminal can be created by using the VE.Direct non inverting remote on/off cable.
3.12. WireBox
The optional MPPT WireBox is a plastic cover that can be attached to the bottom of the solar charger. It covers the battery and solar terminals, preventing accidental or inquisitive contact with the battery and PV terminals. It provides an extra level of safety, and is particularly useful if the solar charger is installed in a general access area. For more information and to find the right MPPT WireBox for your solar charger see the MPPT WireBox product page: · MPPT WireBox-MC4 · MPPT WireBox-Tr
Example of a solar charger with MPPT WireBox

Page 8

Features

MPPT solar charger manual

4. Installation

The DC (PV) input is not isolated from the battery circuit. Therefore the PV, battery and control circuit are considered hazardous and should not be user accessible.
For proper temperature compensated battery charging the ambient temperature of the solar charger and the battery must be within 5°C (9°F).
The battery and PV connections must be guarded against inadvertent contact. Install the solar charger in an enclosure or install the optional WireBox [8].

4.1. Mounting
Mount the solar charger vertically on a non-flammable substrate, with the electrical terminals facing downwards.
If the optional MPPT WireBox is used, affix the steel WireBox base to the solar charger before the solar charger is mounted into its final position. For more information see the MPPT WireBox manual.
The Appendix [61] of this manual contains the dimension drawing of the solar charger, this drawing also indicates the mounting holes.
Observe a minimum clearance of 10cm under and above the solar charger for optimal cooling.
Mount the solar charger close to the battery, but never directly above the battery. This is to prevent damage due to gassing of the battery.
Avoid ambient temperature differences of more than 5°C between the solar charger and the battery. These temperature differences can lead to incorrect temperature compensated charging, which can reduce the battery lifetime.
If large temperature differences or extreme ambient temperature conditions are expected, use a direct battery temperature sense source like the Smart Battery Sense or a BMV or SmartShunt equipped with a temperature sensor.

4.2. Battery
The battery supply must be protected by a fuse as per below table.

Solar charger type MPPT 150/35 MPPT 150/45

Minimum battery fuse rating 40A 50A

For Canada the battery fuse must comply with the C22.2 standards.

Maximum battery fuse rating 45A 63A

The battery installation must be done in accordance with the local storage battery rules. For Canada this is the Canadian Electrical Code, Part I.
Use flexible multi stranded copper cable for the battery connections Also see chapter Wiring safety precautions [1].
4.3. PV array
The solar charger can be used with a PV configuration that satisfies both these two conditions: · The maximum open circuit PV voltage can not exceed 150V · The nominal PV voltage should be at least 5V higher than the battery voltage. The PV array can consist of mono- or poly-crystalline panels. The solar panels are connected in series, in parallel or in series/parallel. See below figure for examples of these configurations.

Page 9

Installation

120 W 12 V

120 W 12 V

MPPT solar charger manual

120 W 12 V

120 W 12 V

120 W 12 V

120 W 12 V

120 W 12 V

120 W 12 V

240 W 24 V 10 A

240 W 12 V 20 A
Examples of series, parallel and series/parallel solar arrays.

480 W 24 V 20 A

To help calculate the size of the PV array configuration use the MPPT sizing calculator. Alternatively, use one of these PV array configurations: PV array example 24V battery with 150V solar charger: · Minimum number of cells in series: 72 (2x 12V panel in series or 1x 24V panel). · Recommended number of cells for highest controller efficiency: 144 cells (4x 12V panel or 2x 24V panel in series). · Maximum: 216 cells (6x 12V or 3x 24V panel in series) PV array example 48V battery with 150V solar charger: · Minimum number of cells in series: 144 (4x 12V panel or 2x 24V panel in series). · Maximum: 216 cells (6x 12V or 3x 24V panel in series).

· Provide a means to disconnect all current-carrying conductors of a photo- voltaic power source from all other conductors in a building or other structure.
· Careful: when calculating the number of panels that can be used in series, make sure to take both its Open circuit voltage (Voc) and its Temperature coefficient into account. At ambient temperatures below 25°C, the Voc will be higher.
· A switch, circuit breaker, or other device, either AC or DC, shall not be installed in a grounded conductor if operation of that switch, circuit breaker, or other device leaves the grounded conductor in an un-grounded state while the system remains energized.
· Do not use solar panels with optimizers. In worst case, the use of optimizers will cause irreparable damage to the solar charger.
· Use flexible multi stranded copper cable for the screw connections . See chapter Wiring safety precautions [1].
· For MC4 models: several of the solar charger’s MC4 pairs may be needed to parallel solar panel strings. Be aware that the maximum current through a MC4 connection cannot exceed 30A.

4.4. Grounding
Battery grounding The solar charger can be installed in a positive or in a negative grounded system. Apply a single ground connection, preferably close to the battery, to prevent system issues or ground loops. PV array grounding The positive and negative of the PV array should not be grounded. Ground the frame of the PV panels to reduce the impact of lightning.

Page 10

Installation

MPPT solar charger manual
Do not connect the solar charger to a grounded PV array. Only one ground connection is allowed, and this should be near the battery. Ground fault detection The solar charger does not have internal ground fault protection. The USA National Electrical Code (NEC) requires the use of an external ground fault protection device (GFPD). The system electrical negative should be bonded through a GFPD to earth ground at one (and only one) location.
When a ground fault is indicated, battery terminals and connected circuits may be un-grounded and hazardous.
4.5. Electrical connections
WARNING: Check the polarity before connecting the battery and PV voltage. WARNING: Follow the correct installation procedure described in this chapter. IMPORTANT: Torque the battery and PV connections at 1.6Nm.
Connection order electrical connections: 1. Connect the battery: allow the solar charger to automatically recognise the system voltage (wait 10 seconds). 2. It is recommended to verify system voltage: use VictronConnect or an external control display. 3. Connect the PV. 4. If applicable, connect the VE.Direct port. The correct connection order is necessary to allow the automatic system voltage detection to setup properly. It is only allowed to connect PV first when the system voltage is manually set before connecting the battery. Not following the correct procedures can disable or damage the charger and/or the installation. See below figure for an example of the solar charger connections:

DC loads

4.6. Connect the MPPT Control display
Connect the (optional) MPPT Control display to the VE.Direct port of the solar charger using a VE.Direct cable. Note that it is not possible to extend the VE.Direct cable, the maximum length can not exceed 10 meter.

Page 11

Installation

MPPT solar charger manual For more information, see the MPPT Control display manual
VE.Direct cable
Connect the display to the solar charger via a VE.Direct cable

Page 12

Installation

MPPT solar charger manual
5. Configuration and settings
The solar charger settings can be configured so it can be taylored specifically for the system it is used in.
Do not change solar charger settings unless you know what they are and what the effect of changing these settings is going to be. Incorrect settings may cause system problems including damage to batteries. When in doubt, seek advice from an experienced Victron Energy installer, dealer or distributor.
5.1. How to change settings
There are several methods that can be used to change these settings. Some of these allow all settings to be configured, but others might have limitations: · The VictronConnect App – All settings can be changed and the firmware can be updated. · The rotary switch – The charge algorithm for a number of pre-set battery types can be selected. · The MPPT Control display (optional) – Most settings can be changed.
Do not change solar charger settings unless you know what they are and what the effect of changing these settings can be. Incorrect settings may cause system problems including damage to batteries. When in doubt, seek advice from an experienced Victron Energy installer, dealer or distributor.
5.1.1. Settings via the VictronConnect App
The VictronConnect App can be used to change all solar charger settings and can be used to update the firmware. This manual only covers the VictronConnect solar charger specific items. For more general information on the VictronConnect App, like how use it or how to connect see the VictronConnect manual.

To access the solar charger settings, navigate to the settings page. Do this by clicking on the cog icon at the top right of the home screen. The settings page provides access to view and/or to change the solar charger settings. For information about each setting and how to update firmware see the All settings explained [15] chapter.
5.1.2. Settings via the rotary switch
The rotary switch can be used to select eight pre-programmed battery charge algorithms. Use a small flathead screwdriver to turn the rotary switch. The arrow indicates which setting number has been selected.

Page 13

Configuration and settings

MPPT solar charger manual The table below indicates the charge algorithm and charge settings for each rotary switch position.

Rotary switch set to position 2
Turning the rotary switch will override the charge settings including settings that were made with the VictronConnect App or with the display. Likewise, if charge settings are changed with the VictronConnect App or the display, this will override the rotary switch setting.

Switch position
0
1
2
3 4 5 6

Suggested battery type

Absorption voltage* (V)

Float voltage*
(V)

Equalize* voltage (V)

Equalize** nominal current
percentage

Temperature compensation factor* (mV/°C)

Gel long life

(OPzV)

14.1

13.8

15.9

-16

Gel Exide A600

28.2

27.6

31.8

8%

-32

(OPzV)

56.4

55.2

63.6

-64

Gel MK

Gel Victron deep discharge

Gel Exide A200

14.3

13.8

16.1

-16

AGM Victron

28.6

27.6

32.2

8%

-32

deep discharge

57.2

55.2

64.4

-64

Stationary

tubular plate

(OPzS)

Default setting

Gel Victron

deep discharge

Gel Exide A200

14.4

13.8

16.2

-16

AGM Victron

28.8

27.6

32.4

8%

-32

deep discharge

57.6

55.2

64.8

-64

Stationary tubular plate (OPzS)

AGM spiral cell

Stationary

14.7

13.8

16.5

-16

tubular plate

29.4

27.6

33.0

8%

-32

(OPzS)

58.8

55.2

66.0

-64

Rolls AGM

PzS tubular

14.9

13.8

16.7

-16

plate traction batteries or

29.8

27.6

33.4

25%

-32

OPzS batteries

59.6

55.2

66.8

-64

PzS tubular

15.1

13.8

16.9

-16

plate traction batteries or

30.2

27.6

33.8

25%

-32

OPzS batteries

60.4

55.2

67.6

-64

PzS tubular

15.3

13.8

17.1

-16

plate traction batteries or

30.6

27.6

34.2

25%

-32

OPzS batteries

61.2

55.2

68.4

-64

  • The top value is for 12V systems, the middle for 24V systems and the bottom for 48V systems. ** Equalize is by default disabled. To enable see chapter Battery settings [16]

Page 14

Configuration and settings

MPPT solar charger manual

Switch position
7

Suggested battery type

Absorption voltage* (V)

Float voltage*
(V)

Equalize* voltage (V)

Equalize** nominal current
percentage

Temperature compensation factor* (mV/°C)

Lithium Iron

14.2

13.5

0

Phosphate (LiFePo4)

28.4

27.0

n/a

n/a

0

batteries

56.8

54

0

  • The top value is for 12V systems, the middle for 24V systems and the bottom for 48V systems. ** Equalize is by default disabled. To enable see chapter Battery settings [16]

A binary LED code helps determining the position of the rotary switch. After changing the position of the rotary switch, the LEDs will blink during 4 seconds as indicated in below table. Thereafter, normal indication resumes, as described in the LEDs section.

Switch position 0 1 2 3 4 5 6 7

Bulk LED 1 0 0 0 1 1 1 1

Absorption LED 1 0 1 1 0 0 1 1

Float LED 1 1 0 1 0 1 0 1

Blinking frequency Fast Slow Slow Slow Slow Slow Slow Slow

5.1.3. Settings via MPPT Control display
The MPPT Control display can be used to configure solar charger settings, with the exception of advanced settings such as RX and TX port settings. For information how to do this see the MPPT Control display manual.

The MPPT Control display
5.2. All settings explained
This chapter lists all solar charger settings that are user-configurable and also explains how to update firmware of the solar charger.
Do not change settings unless you know what they are and what the effect of changing these settings will be. Incorrect settings may cause system problems including damage to batteries. When in doubt, seek advice from an experienced Victron Energy installer, dealer or distributor.

Page 15

Configuration and settings

5.2.1. Battery settings

MPPT solar charger manual

Battery voltage The battery voltage is automatically detected at the very first power-up of the solar charger and the battery voltage is set accordingly. Further automatic detection is disabled. To make sure that a stable measurement is used, the charger first waits 10 seconds, and thereafter takes an averaged measurement. Note that the solar charger will remain off during this time. In case the solar charger does not measure a battery voltage, it will default to 12V and store that. This will happen if the solar charger is powered via its PV terminals, while not connected to a battery. Note that the solar charger will not automatically detect a 36V battery. This will need to be set manually. After automatic detection has taken place, the battery voltage can be changed and set to 12, 24, 36 or 48V, if so required .
Tip: If the firmware of the solar charger needs to be updated, while keeping the automatic voltage detection active, for example before shipping the unit to an end-user, do the following: · Update the firmware.
· Once the firmware update is complete, go to the settings page in the VictronConnect app.
· On the settings page, click on the three vertical dots in the upper right corner and select “Reset to defaults” from the drop-down menu.
· Un-power the solar charger within 10 seconds.
The next time that the unit is powered up, it will perform the initial automatic voltage detection.
Max charge current This setting sets the maximum battery charge current. It is by default set to the maximum solar charge current. Use this setting to reduce the charge current, for example, when a smaller battery bank is used that requires a lower charge current. Charger enabled This setting enables or disables the battery charger. It is by default set to “enabled”. This setting can be used when work needs to be carried out on the installation. When this setting is disabled, the batteries will not be charged. Battery preset This setting sets the battery charge algorithm. It is by default set to “rotary switch”. A selection can be made between:

Page 16

Configuration and settings

MPPT solar charger manual
· The rotary switch position · Pre-defined factory battery presets · User- defined battery presets · Create, modify or delete a user-defined preset. This setting uses factory pre-defined presets for a large variety of battery types. These pre-defined charge algorithms are suitable for almost all installations. It is possible to also create user-defined battery presets. The chapter Customize battery charge algorithm [17] explains how to do this. These user- defined presets are stored in the VictronConnect app library. This is helpful in case multiple solar chargers need to be configured, eliminating the need to define the entire charge algorithm each time a new solar charger is configured. Expert mode This setting enables or disables expert mode. It is by default set to “disabled”.
The default charge algorithms work well for almost all installations. Only enable expert settings if your equipment has special requirements.
When this setting is enabled the following parameters can be configured: · Charger voltages: bulk, absorption and float · Bulk: re-bulk voltage offset · Absorption: duration, time and tail current · Equalization: current, interval, stop mode and duration · Temperature voltage compensation · Low temperature cut off For the meaning of these parameters see chapter Battery charge algorithm settings [19] Equalization
Equalization can cause damage to the battery if the battery is not suitable for an equalization charge. Always check with the battery manufacturer prior to enabling equalization.
This setting can be used to disable or enable automatic equalization. When enabled, the number of days can be selected when equalization should repeat. A manual equalization can be initiated by pressing the “START NOW” button. Use the manual equalize option only during absorption and float charge stages, and when there is sufficient sunlight. The current and voltage limits are identical to the automatic equalize function. The manual equalization stage lasts 1 hour and can be stopped at any time by the Stop Equalize.
The equalization setting might not be active, this can be the case if the battery preset does not support an equalization charge which is the case with lithium batteries.
Customize battery charge algorithm This chapter explains how to modify a battery charge algorithm or to create, modify and delete user defined battery presets. See the Battery charge algorithm settings [19] chapter for the meaning of all charge algorithm parameters.

Page 17

Configuration and settings

MPPT solar charger manual

Only experienced users should configure or edit user defined battery charge algorithms. A wrongly defined battery charge algorithm can lead to battery damage or create unsafe situations.
To Modify a basic battery charge algorithm: · Select a preset battery type that is the best match to your battery type. · Change one of the basic charge parameters that are listed on the settings screen. · Configure the required parameters. · The battery preset is now set to “user defined”. To Modify an expert battery charge algorithm · Enable “Expert” mode. · The basic and additional charge parameters are now listed on the screen. · Configure the required parameters. · The battery preset is now set to “user defined”. To create and save a custom battery type: · Select a preset battery type that is the best match to your battery type. · Change the charge parameters so they match your battery. This can be done either in normal mode or in expert mode. · The battery preset is now set to “user defined”. · Select in the “Battery preset” menu “Create preset”. · Give the preset battery a name. To load a custom battery type: · Select in the “Battery preset” menu “Select preset”. · The menu lists all factory preset and custom battery types that were previously added (if any). · Select the battery type of your choice. To modify (or delete) a custom battery type: · Select in the “Battery preset” menu “Edit presets” · Navigate to the battery you want to modify. It is not possible to modify a factory preset, only custom types can be modified (or
deleted). · Modify the charge parameters.

Page 18

Configuration and settings

MPPT solar charger manual
· To save the settings press the “SAVE CHANGES” button at the bottom of the page. · To delete the battery, press the “REMOVE PRESET” button. Battery charge algorithm settings This chapter explains all parameters that are used in “Expert” mode and the settings that are used when programming a custom battery type via the battery preset menu.

Absorption voltage
This setting sets the absorption voltage.
Adaptive absorption time
This setting enables or disables the adaptive absorption time.
· When disabled: The length of the absorption stage is the same each day, the length is determined by the “Maximum absorption time” setting, provided there is enough solar power. Be aware that this option can potentially result in overcharging your batteries, especially for lead batteries and if only shallow daily discharges take place. Check with the battery manufacturer for the recommended maximum absorption time. The only condition that can end the absorption time before the maximum time has been reached, is the “tail current” setting. If the absorption time always needs to be the same length, then disable the “Tail current” setting. See more information on the tail current setting further down in this chapter.
· When enabled: The length of the absorption stage is different each day, it adapts itself to the state of charge of the battery in the morning at the beginning of the charge cycle. The maximum “adaptive” absorption time for the day is determined by the battery voltage as measured just before the solar charger begins operation each morning.

Multiplier

x 1

x 2/3

x 1/3

x 1/6

Adaptive absorption time *

6:00 hours

4:00 hours

2:00 hours

1:00 hour

12V system

Vbatt < 11.9V

11.9V < Vbatt < 12.2V

12.2V < Vbatt < 12.6V

Vbatt > 12.6V

24V system

Vbatt < 23.8

23.8 < Vbatt < 24.2V

24.2V < Vbatt < 25.2V

Vbatt > 25.2V

48V system

Vbatt < 47.6

47.6V < Vbatt < 48.8V

48.8V < Vbatt < 50.4V

Vbatt > 50.4

*) The adaptive absorption time is calculated by the multiplier times the “Maximum absorption time” setting. The adaptive absorption times in this table are based on the 6 hour default “Maximum absorption time” setting.

Maximum absorption time This setting sets the absorption time limit. This setting is only available when programming a custom charge profile.

Page 19

Configuration and settings

MPPT solar charger manual

Enter the maximum time in hours and minutes (hh:mm) the solar charger is allowed to spend in the absorption stage. The maximum time that can be set is 12 hours and 59 minutes.
Float voltage
This setting sets the float voltage.
Re-bulk voltage offset
This setting sets the re-bulk voltage offset. This offset voltage is used to determine when a charge stage stops and the bulk stage starts again, i.e. the charge cycle resets and starts at the first charge stage again.
The re-bulk voltage is calculated by adding the re-bulk voltage offset to the lowest voltage setting (normally this is the float stage).
An example: If the re-bulk offset is set at 0.1V and the float voltage at 13.8V, the charge cycle will restart once the battery voltage drops below 13.7V (13.8 minus 0.1) for one minute.
Equalization voltage
This setting set the equalization voltage.
Equalization current percentage
This setting sets the percentage of the “maximum charge current” setting that will be used to calculate the equalization charge current.
For example: If the “maximum charge current” setting is set at 10A and the “Equalization current percentage” setting is set to 10%, the Equalization current will be 1A (10% of 10A).
Automatic equalization
This setting sets the repeat interval when the equalization stage should take place. This can be set between 1 and 250 days. Setting to 1 means a daily equalization, 2 means every other day and so on.
An equalization stage is typically used to balance the cells and also to prevent stratification of the electrolyte in flooded lead-acid batteries. If equalization is needed or not depends on the type of battery if (automatic) equalization is needed and under what conditions. Check with the battery supplier to find out if equalization is needed for the battery.
During the equalization stage, the charge voltage increases up to the set “Equalization voltage”. This is maintained as long as the charge current stays below the “equalization current percentage” setting of the “Maximum current” setting.
Duration of the Automatic equalization cycle:
· For all VRLA battery presets and for some flooded battery presets, the automatic equalization stage ends when the voltage limit (maxV) has been reached.
· For the lithium battery preset, equalization is not available.
· When an automatic equalization stage has not been completed within one day, it will not resume the next day. The next equalization surge will take place according to the interval as set in the “Auto Equalization” setting.
Equalisation stop mode
This setting determines when the equalisation stage should end:
· Automatic: Equalization stops if the battery voltage has reached the equalisation voltage
· Fixed time: Equalization stops when the time has reached the time as set in the “Maximum equalization duration” setting.
Maximum equalization duration
This setting sets the maximum time that the equalization stage will last.
Manual equalization
Use this to perform a “once-off” equalization. Once the “start now” button is pressed, a one-hour equalization cycle will be performed, alternatively, the equalization stage can be stopped manually.
Tail current
This setting sets the current threshold to end the absorption stage before the maximum absorption time has been reached. If the charge current drops below the set tail current, for one minute, the absorption stage will end and the float stage will start. This setting can be disabled by setting it to zero.
Temperature compensation
This setting sets the temperature compensation coefficient that is needed for temperature compensated charging.
Many battery types require a lower charge voltage in warm operating conditions and a higher charge voltage in cold operating conditions. The configured coefficient is in mV per degree Celsius for the whole battery bank, not per cell. The base temperature for the compensation is 25°C (77°F).

Page 20

Configuration and settings

MPPT solar charger manual
The chart below indicates the absorption and float charge voltage behaviour at different temperatures. The graph displays the temperature compensation for a 12V system and uses a -16mV/°C temperature compensation coefficient. For a 24V system multiply the voltages by 2 and for a 48V system multiply by 4.

Temperature compensated charge graph
By default, the solar charger uses its internal temperature for battery temperature compensated charging. An internal temperature reading is taken in the morning and then again when the e solar charger has been idle for at least one hour, for example when the charger is not actively charging a battery or supplying a load.
When the solar charger is part of VE.Smart Networking and receives a battery temperature reading from a Battery Sense or a battery monitor with a temperature sensor, the actual battery temperature will be used for temperature compensated charging throughout the day.
Low temperature cut-off
This setting is used to prevent damage to a lithium battery by disabling charging at low temperatures.
The “Low temperature cut-off” feature is only active when the solar charger is part of a VE.Smart network and is receiving a battery temperature reading from a Battery Sense or a battery monitor with temperature sensor.
The “low temperature cut-off” setting is by default disabled. When enabled, a low cut off temperature can be set. The default temperature is 5°C, this is a suitable temperature setting for lithium iron phosphate (LFP) batteries. However, always check with the lithium battery supplier to find out what this temperature should be set at.
The “low temperature cut-off” mechanism will stop battery charging when the battery temperature has dropped below the low temperature cut-off setting. Battery charging will resume once the battery temperature has risen 0.5°C above the low temperature cut-off setting.
Note that setting “low temperature cut-off” is not needed for Victron Lithium Smart batteries or for Victron Super Pack batteries with serial number HQ2040 and above. This setting is only needed for lithim batteries that are unable to block charging when the temperature drops too low.
5.2.2. Load output settings
The load output settings be used to drive the TX pin in the VE.Direct port, which can then be used to drive a BatteryProtect, a relay or an other load- shedding device. For more information see chapter TX port settings [25].

Page 21

Configuration and settings

MPPT solar charger manual

The available operation modes are: · Always off
The load output is always OFF
· BatteryLife algorithm: This is a self adapting algorithm to maximize life of the battery. For more information see chapter ???.
· Conventional algorithm 1: 12V system: OFF when Vbatt < 11.1V, ON when Vbatt

13.1V 24V system: OFF when Vbatt < 22.2V, ON when Vbatt > 26.2V 48V system: OFF when Vbatt < 44.4V, ON when Vbatt > 52.4V
· Conventional algorithm 2: 12V system: OFF when Vbatt < 11.8V, ON when Vbatt 14.0V 24V system: OFF when Vbatt < 23.6V, ON when Vbatt > 28.0V 48V system: OFF when Vbatt < 47.4V, ON when Vbatt > 56.0V
· Always on: The load output is always ON
· User defined algorithm 1: OFF when Vbatt < Vlow, ON when Vbatt > Vhigh.
· User defined algorithm 2: OFF when Vbatt < Vlow or Vbatt > Vhigh and ON when Vbatt is between Vlow and Vhigh.
· Automatic Energy Selector: OFF when Vbatt < Vlow. And ON when Vbatt > Vhigh. When conditions are met Load will be on for a pre-selected time.
The “always off” and the “always on” modes will respond immediately. The other modes have a 2 minute delay before the load output changes. This is so that the solar charger does not respond too quickly when, for example, an inrush current briefly lowers the battery voltage below the threshold. The load output settings also controls the streetlight algorithm. Both work together to protect the battery from being too deeply drained. The streetlight settings are overridden should the battery voltage falls below the load disconnect voltage. When the battery voltage increases to the load reconnect voltage, the streetlight function will resume.
5.2.3. Streetlight settings
The streetlight function enables the solar charger to automatically control night lighting. It will automatically determine when the light should be on or off and can control the light intensity.

Page 22

Configuration and settings

MPPT solar charger manual
When the streetlight function is enabled a timer program can be created whereby Sunset, Sunrise as well as Midnight can be used as anchor points for the timer program. These anchor points will automatically adjust depending on length of the night as this changes with the seasons.

Streetlight control
The solar charger controls the streetlight:
· Via the TX port together with a VE.Direct TX digital output cable. Also see the TX port settings [25] chapter for more details.
The streetlight algorithm is always applied in conjunction with the settings as configured in the Load output menu:
· If the streetlight is disabled, then the (virtual) load output is controlled only by the configuration as made in the load output menu.
· If streetlight is enabled, then it’s an AND function: the load output will be on when both the conditions made in the Load output menu are satisfied as well as the streetlight settings. Otherwise, it’s off.
Make sure that load output setting is set to “Always on” or to “BatteryLife”. Do not set it to “Always off” as this will result in the light being always off.
For more configurable voltage levels to force the light off, the other load output options can also be used.
Setting the Sunset action
At sunset you can choose any of the following actions:
· Keep the lights off
· Switch on for a fixed time: This option will turn the light on at sunset, and then off again after a configurable interval. When the dimming feature is enabled1 (1), two dim-levels can be entered: one for the “on” period; and a second for the “off” period. A typical use case for these options is to get a strong light during high traffic hours (right after sunset), and lower intensity during the low hours, to save the battery. Set the second dim level to 0% to switch the light completely off during that second section.
· Switch on till midnight: This option turns the light on at sunset, and then off again at midnight. When the dimming feature is enabled1, two dim-levels can be entered: one for the “on” period (up to midnight) and a second dim- level for the “off” period after midnight. Set the second dim level to 0% to switch the light completely off during that second section.
· Switch on till sunrise: This options turns the light on at sunset, and then off again at sunrise. When this option is selected; there is no need to also select an action at sunrise, so the sunrise control option is not needed. When the dimming feature is enabled1, only one dim level can be configured, the dim level at sunset.

Page 23

Configuration and settings

MPPT solar charger manual

  1. The dimming feature requires the TX Port function to be configured to one of the “Light dimming” settings. This so the TX port outputs a PWM signal that can be used to dim the light. If the TX port function has not been set to one of the “Light dimming” settings, the dimming options will not appear in the sunset settings menu. Also see the TX port settings [25] chapter.
    Setting the Sunrise action
    At sunrise you can choose to:
    · Switch off: Turns the light off at sunrise
    · Switch on before sunrise: This option switches the light on at a configurable time interval before sunrise, and then switches the light off at sunrise. In case the dimming feature is enabled1 an interval of more intense light can be configured during early morning rush hour. Together with the Sunset action, you can now configure three dim levels: one for the sunset rush hours, one during the low traffic hours, and the third for the early morning rush hours.
    Midnight
    The charger has no real time clock, and therefore does not know when it is 12 o’clock at night. All references to midnight refer to what we call solar midnight, this is the mid-point between sunset and sunrise.
    Midnight and Sunrise synchronisation
    The solar charger needs to have its internal clock synchronised with the solar cycle so it can set the solar midnight and sunrise anchor points in the timer program.
    After the streetlight settings have been programmed and the solar charger is powered up, the solar charger will start unsynchronised. It will first assume that midnight is 6 hours after sunset, and that the full night last for 12 hours.
    Once in operation, the solar charger will check the time between each detected sunrise. After three full day/night cycles, where the detected time is approximately 24 hours (one hour of deviation is allowed), it will start using its internal clock, instead of the fixed 6 and 12 hour timing.
    A loss of power (no battery power together with no PV power) will cause the solar charger to loose its synchronisation. It will take 5 days before it is re-synchronised. Note that the streetlight configuration settings and all other settings will never be lost, they are stored in a non-volatile memory.
    Sunset and sunrise detection
    The sunset and sunrise detection voltage settings can be used to adjust the detection to match the panel configuration. The sunrise detection voltage must be 0.5V higher than the sunset detection level. The lowest detectable voltage is 11.4V. Set this option to 0 to use the built-in defaults, which are:
    · Sunset = Vpanel < 11.4V
    · Sunrise = Vpanel > 11.9V
    The default setting is 0, which uses built-in default voltages.
    Use the “Delay” periods to avoid the system making an accidental switch when clouds pass over the panels. The valid range is between 0 and 60 minutes. The “Delays” are disabled by default (0).
    Gradual dimming speed
    The gradual dimming option can be used to slow down the response of the timer program. This is useful when multiple streetlights are used in a row. This helps to mask the fact that each timer uses its own detection and will have a transition moment which will vary from unit to unit.
    The dimming settings can be adjusted. You can input the number of seconds required to achieve each percentage-point of change (x seconds/per 1% of dimming). A number from 0 to 100 can be entered. Two examples:
    · 0 = immediate response (gradual dimming disabled): A setting of 0 will achieve an immediate response, this effective means that the gradual dimming option is disabled.
    · 9 = dim from 0 to 100% in 15 minutes: Setting the dimming speed to 9, for example, slows down the dimming speed to 15 minutes (9 seconds for each percentage point of dimming x 100 percentage points = 900 seconds = 15 minutes.
    Make sure that the TX port function is set to “Light dimming” mode (as described in point 1 at the beginning of this chapter) and connect a VE.Direct TX digital output cable to the PWM dim input of your LED driver.
    Mid-point shift

Page 24

Configuration and settings

MPPT solar charger manual
The time of midnight is estimated based on solar activity, and depends on your geographical location. Daylight saving times can cause a further deviation between the “solar” and the “clock” midnight. The Mid-point shift function will compensate for these differences. Use 0 to disable the shift (default).
The Mid-point shift setting is only relevant when your streetlight setting program uses “Midnight” as a switching moment.
Calculation Example: For calculation we use a day of 1440 minutes, where Sunset is at 19:00 (1140 minutes) and Sunrise is at 6:25 (385 minutes): · The night duration in minutes is: 1440m(min/day) -1140m(time to sunset) + 385m(time to sunrise) = 685m · The degree of shift = time of sunset(minutes) + half the duration of night(minutes) – length of day(minutes) = 1140m + 342m – 1440m =
42 minutes. Example configuration

The selections which have been made on above screen image results in this program: · At sunset – the light will be switched on for a fixed time · Dim level at sunset – at Full brightness (100%) · Keep lights on during – the duration has been set to 1h 0m · Dim level at end – at the end of one hour the brilliance will be reduced to half (50%) Also: · At sunrise – the lighting will be adjusted before sunrise · Time before sunrise – at 1h 0m before sunrise, the following adjustment will be made: · Dim level – full brilliance will be restored (100%)
5.2.4. TX port settings
The VE.Direct-TX port can be used to send a signal to an external device. For example to send a PWM signal to dim a streetlight. To use the TX port, a VE.Direct TX digital output cable is needed.

Page 25

Configuration and settings

MPPT solar charger manual

The functionality of the TX port can be set at:
· Normal communication: This is the default setting. Use this function when connecting to a GX device, a VE.Direct Bluetooth Smart dongle, or any other device that needs to communicate with the solar charger via the VE.Direct port.
· Pulse every 0.01 kWh: Use this function in combination with an energy meter. The TX port will emit a pulse each time an additional 0.01kWh of energy has been harvested. The TX port is normally high and will be driven low for approximately 250ms for every 0.01kWh harvested.
· Light dimming (PWM normal): Use this function in combination with the “Streetlight” setting. The TX port PWM signal will be at 100% duty cycle when full light intensity is required.
· Light dimming (PWM inverted): Use this function in combination with the “Streetlight” setting. The TX port PWM
signal will be at 0% duty cycle when full light intensity is required.
· Virtual load output: Use this function to create a virtual load output if the solar charger does not have a physical load output. The TX port will switch using the same conditions as set in the load output settings. Connect the VE.Direct TX digital output cable to a BatteryProtect module, a relay or directly to the remote on/off connector of the load.
*) The PWM signal is 5V, 160Hz.
Note that these functionalities (other than the first functionality) does not disable the ability of the unit to communicate. What happens is that the unit will automatically detect incoming data, and while data is being received it will resume normal communication. Once the data-reception has been completed it will automatically return to its configured TX function.
For more in depth “developer style” information on the VE.Direct port see Technical Information: Data communication with Victron Energy products .
5.2.5. RX port settings
The VE.Direct-RX port can be used to receive a signal from an external device. For example to switch the solar charger on (or off) from a signal sent by a battery management system (BMS).
To use the RX port for remote on/off control a VE.Direct non inverting remote on/off cable is needed.

Page 26

Configuration and settings

MPPT solar charger manual

The functionality of the RX port can be set at: · Remote on/off:
This is the default setting. This functionality will switch the solar charger on or off via the RX pin. – RX pin to GND will switch the solar charger off. – RX pin floating or to battery positive will switch the solar charger on. · Load output on/off inverted: This setting reverses the load output on/off control: – RX pin 0V will switch load output on – RX pin +5V will switch load output off · Load output on/off normal: This setting allows load output on/off control: – RX pin 0V will switch the load output off – RX pin +5V will switch load output on For more in depth “developer style” information on the VE.Direct port see the Data communication with Victron Energy products Whitepaper.
5.3. Updating firmware
The firmware can be checked and updated with VictronConnect. VictronConnect might ask on first connection to update firmware. If this is the case, let it perform a firmware update. If it did not automatically update, check if the firmware is already up to date using the following procedure: · Connect to the solar charger
· Click on the settings symbol
· Click the option symbol · Go to product info · Check if you are running the latest firmware and look for the text: “This is the latest version” · If the solar charger does not have the most up to date firmware, perform a firmware update
5.4. Disabling and enabling Bluetooth
Bluetooth is by default enabled. It can be disabled or enabled via the VictronConnect App. To disable or enable Bluetooth:

Page 27

Configuration and settings

MPPT solar charger manual
· Connect with the VictronConnect App to the solar charger. Note that if Bluetooth has been disabled, a connection via its built-in Bluetooth is not possible anymore. In that case use the VE.Direct to USB interface, the VE.Direct Bluetooth Smart dongle or VRM to connect to the solar charger.
· Select the solar charger from the VictronConnect list. · Navigate to the solar charger settings page by clicking the cog symbol in the top right hand corner. · Navigate to the product info page by clicking on the 3 dot symbol in the top right hand corner. · Enable or disable the Bluetooth setting. · In case of disabling Bluetooth, tick the checkbox confirming you understand that once Bluetooth has been disabled, a Bluetooth
connection with the solar charger is not possible anymore.

5.5. VE.Smart Networking

Disablig or enabling Bluetooth

The VE.Smart Networking allows a variety of products connected to the same network to share data via Bluetooth. The VE.Smart Networking is especially designed for smaller systems that do not have a GX device installed.
When this product is part of a VE.Smart Networking it can receive data or communicate with the following devices:
· All SmartSolar solar chargers

Page 28

Configuration and settings

MPPT solar charger manual

· All BlueSolar solar chargers that are connected to a VE.Direct Bluetooth Smart dongle.
· The Smart Battery Sense
· A BMV or SmartShunt battery monitor equipped with Bluetooth (or VE.Direct Bluetooth Smart dongle) and a optional BMV temperature sensor.
· Certain AC chargers
· SUN inverter
For the product compatibility list see the VE.Smart manual located on the VictronConnect app product page. The VE.Smart Networking can be used for: · Temperature sensing – the measured battery temperature is used by the chargers in the network for temperature compensated
charging and in case of lithium battery for the low temperature cut off.
· Battery voltage sensing – the measured battery voltage is used by the chargers in the network to to compensate the charge voltage should there be a voltage drop over the battery cables.
· Current sensing – The measured battery current is used by the charger so it knows the exact tail current at which the absorption stage should end and the float (or equalisation) stage should start. To measure the charge current all charge currents from all chargers are combined, or if a battery monitor is part of the network the actual battery current will be used.
· Synchronised charging – All chargers in the network will act as they were one large charger. One of the chargers in the network will assume a master role and the master will dictate the charge algorithm the other chargers will be using. All chargers will follow the same charge algorithm and charge stages. The master is selected randomly (not user settable) so it is important that all chargers use the same charge settings. During synchronised charging each charger will charge up to its own maximum charge current setting (it is not possible to set a maximum current for the whole network). For more information see the VE.Smart manual located on the VictronConnect app product page.
This video introduces the Smart Battery Sense and some features of the VE.Smart Networking:

5.5.1. VE.Smart Networking setup
VE.Smart Networking design notes: There can only be one product in the network that transmits battery voltage and/or battery temperature. It is not possible to use a battery monitor together with a Smart Battery Sense, or multiples of these devices. For the network to be operational all networked devices must be within Bluetooth transmission distance of each other. A maximum of 10 devices can be joined into a VE.Smart Networking. Some older devices might not support VE.Smart Networking. for more information see the Limitations chapter in the VE.Smart Networking manual. Setting up the network When setting up the network, first set up the Smart Battery Sense or battery monitor, and then add one or more solar chargers or AC chargers to the network. All solar chargers and AC chargers need to have the same charge settings. The easiest way to do this is to use a preset battery type or a saved used defined battery type. A warning #66 message will be shown if there is a difference between the devices charge settings. To set up a new network: · Open the VictronConnect app.
· Select one of the devices that needs to become part of the new VE.Direct network.
· Navigate to the settings page by clicking the gear symbol.
· click on “VE.Smart networking”.
· Click on “create network”.
· Enter a name for the new network.
· Click “save”.
· Wait for confirmation that the network has been set up and click “OK”.

Page 29

Configuration and settings

MPPT solar charger manual
· If more devices need to be added to this network go to next paragraph and join multiple devices to the network. To join another device to an existing network: · Open the VictronConnect app. Select a device that needs to become part of a VE.Direct network. · Navigate to the settings page by clicking the gear symbol. · Click on “VE.Smart Networking”. · Click on “join existing”. · Select the network the device needs to be joined to. · Wait for confirmation that the network has been set up and click “OK”. · Repeat above steps if more devices need to be added to the network. To leave a network: · Open the VictronConnect app. · Select a device that needs to be removed from the VE.Direct network. · Navigate to the settings page by clicking the gear symbol. · Click on “VE.Smart Networking”. · Click on “leave network”. Check the network Once the network has been set up all devices communicate with each other. The active LED on each connected device will now blink every 4 seconds. This is an indication that the device is actively communicating with the network. To check if an individual device is communicating with the network, click on the VE.Smart symbol in the main screen next to the solar dail. A pop- up window will open showing the connection status and the shared parameters.

VE.Smart Networking pop-up
To check if all devices are actively communicating with the same VE.Smart Networking, navigate to the settings page of one of the networked devices and click on “VE.Smart Networking”. A screen will be shown containing which device parameters of this device are shared and all the other devices that are connected to the same network are shown.

Page 30

Configuration and settings

MPPT solar charger manual
Example of a VE.Smart Networking More information For more information see the VE.Smart Networking manual.

Page 31

Configuration and settings

MPPT solar charger manual

6. Operation

6.1. Start up
The solar charger will power up as soon as it has been connected to a battery and/or to a solar panel. As soon as the solar charger has been powered up, it can communicate via the VE.Direct port and Bluetooth. The the solar charger’s data can be read out and setting configurations can be made using the VictronConnect or the optional display.
The solar charger will commence battery charging as soon as the PV voltage is 5V higher than the battery voltage. For charging to continue, the PV voltage must remain at least 1V higher than the battery voltage.

6.2. Battery charging
The charge controller will start a new charge cycle every morning, when the sun starts shining and when the PV voltage is 5V higher than the battery voltage.
Default method to determine length and end of absorption for Lead-acid batteries
The charging algorithm behaviour of solar chargers differ from AC connected battery chargers. Please read this section of the manual carefully to understand the solar charging behaviour, and always follow the recommendations of your battery manufacturer.
The voltage values mentioned in this chapter are for 12V systems, for 24V systems multiply by 2 and for 48V systems multiply by 4.

By default, the absorption time is determined on idle battery voltage at the start of each day based on the following table:

Battery voltage at start up < 11.9V 11.9V – 12.2V 12.2V – 12.6V > 12.6V

Multiplier x 1 x 0.66 x 0.33 x 0.16

Maximum absorption time 6h 4h 2h 1h

The default absorption voltage is 14.4V and the default float voltage is 13.8V.
The absorption time counter starts once switched from bulk to absorption.
The MPPT solar chargers will also end absorption and switch to float when the battery current drops below a low current threshold limit, the “tail current”. The default tail current value is 2A.
The default settings (voltages, absorption time multiplier and tail current) can be modified with the VictronConnect App.
There are two exceptions to normal operation:
· When used in an ESS system; the solar charger algorithm is disabled; and instead it follows the curve as mandated by the inverter/charger.
· For CAN-bus Lithium batteries, like BYD, the battery tells the system, including the solar charger, what charge voltage to use. This Charge Voltage Limit (CVL) is for some batteries even dynamic; changes over time; based on for example maximum cell voltage in the pack and other parameters.
Variations to the expected charging behaviour
· Pausing of the absorption time counter: The absorption time counter starts when the configured absorption voltage is reached and pauses when the output voltage is below the configured absorption voltage. An example of when this voltage drop could occur is when PV power (due to clouds, trees, buildings) is insufficient to charge the battery and to power the loads.
· Restarting the charge process: The charging algorithm will reset if charging has stopped for an hour. This may occur when the PV voltage drops below the battery voltage due to bad weather, shade or similar.
· Battery being charged or discharged before solar charging begins: The automatic absorption time is based on the start-up battery voltage (see table). This absorption time estimation can be incorrect if there is an additional charge source (eg alternator) or load on the batteries. This is an inherent issue in the default algorithm. However, in most cases it is still better than a fixed absorption time regardless of other charge sources or battery state. It is possible to override the default absorption time algorithm by setting a fixed absorption time when programming

Page 32

Operation

MPPT solar charger manual

the solar charge controller. Be aware this can result in overcharging your batteries. Please see your battery manufacturer for recommended settings.
· Absorption time determined by tail current:
In some applications it may be preferable to terminate absorption time based on tail current only. This can be achieved by increasing the default absorption time multiplier (warning: the tail current of lead-acid batteries does not decrease to zero when the batteries are fully charged, and this “remaining” tail current can increase substantially when the batteries age).
Default settings for LiFePO4 batteries
The default absorption voltage is to 14.2V (28.4V, 56.8V) and the absorption time is fixed and set to 2 hours. The float voltage is set at 13.5V (27V, 54V). Equalization is disabled. The tail current is set to 0A, this so that the full absorption time is available for cell balancing. The temperature compensation is disabled and the low temperature cut off is set to 5. These settings are the recommended settings for LiFePO4 batteries, but they can be adjusted if the battery manufacturer specifications advise otherwise.
Reset of the charge algorithm:
The default setting for restarting the charge cycle is Vbat < (Vfloat ­ 0.4 V) for lead-acid, and Vbat (Vfloat ­ 0.1 V) for LiFePO4 batteries, during 1 minute. These values are for 12 V batteries, multiply by two for 24V and by four for 48V.

6.3. Automatic equalization
Do not equalize charge Gel, AGM, VRLA or lithium batteries.
Equalization can cause damage to the battery if the battery is not suitable for an equalization charge. Always check with the battery manufacturer prior to enabling equalization.
Automatic equalization is by default disabled. When enabled, it can be configured with a number between 1 (every day) and 250 (once every 250 days).
When automatic equalization is active, the absorption charge will be followed by a voltage limited constant current period. The current is by default limited to 8% of the bulk current and can be adjusted between 0% and 100%. The bulk current is set by default to the maximum charge current the solar charger is capable of, unless a lower charge current has been chosen.
The maximum equalization duration is set by default to 1 hour and can be configured between 0 minutes and 24 hours. The automatic equalization will end when the voltage limit has been reached or when the set maximum equalization duration has been reached, whichever comes first.
When automatic equalization has not finished within a day, it will not resume the next day. The next equalization session will take place as determined by the day interval.

6.4. Lithium batteries
Lithium Iron Phosphate (LiFePo4) batteries do not need to be fully charged to prevent premature failure. The default lithium (and recommended) settings are:

Setting Absorption voltage Absorption time Float voltage

12V system 14.2V 2h 13.2V

24V system 28.4V 2h 26.4V

48V system 56.8V 2h 52.8V

These settings are adjustable.

6.5. Shutdown and restart procedure
The solar charger is always active when the PV and/or the battery terminals are powered. The solar charger does not have an on/off switch. To shut down the solar charger, perform these steps in the prescribed order: 1. Disconnect the PV supply to the solar charger by switching the PV supply off or by removing the fuse(s).
2. Disconnect the battery supply to the solar charger by switching the battery supply off or by removing the fuse(s).
To restart the solar charger after it was shutdown, perform these steps in the prescribed order: 1. Connect the battery supply to the solar charger by switching the battery supply on or by inserting the fuse(s).
2. Reconnect the PV supply to the solar charger by switching the PV supply on or by inserting the fuse(s).

Page 33

Operation

MPPT solar charger manual
6.6. Maintenance procedure
The solar charger does not need regular maintenance.

Page 34

Operation

MPPT solar charger manual

7. Monitoring

This chapter describes all various monitoring methods and for each method how to access live data, historic data and errors.

7.1. LED indications
The solar charger has three LEDs to indicate operational status, a blue, green and a yellow LED. These LEDs respectively indicate the charge stages bulk, absorption and float, but are also used to indicate other charge situations and fault situations.
Errors are indicated via a combination of LEDs that are on, off, or are blinking. Each LED combination has a meaning, indicating either a normal operation mode, or indicating an error.

Symbol

Meaning Permanent on

Blinking

Off

Overview of LED indications: Operation mode
Not charging 1
Bulk1
Absorption2 Manual equalisation (alternating blinking)2 Automatic equalisation2
Float2

Bulk LED

Absorption LED

Float LED

1. The bulk LED will blink briefly every 3 seconds when the system is powered but there is insufficient power to start charging.
2. The LED(s) might blink every 4 seconds indicating that the charger is receiving data from another device, this can be a GX device (ESS) or a VE.Smart Network link via Bluetooth

Fault mode Charger temperature too high

Bulk LED

Absorption LED

Float LED

Charger over-current

Charger or panel over-voltage
VE.Smart networking or BMS issue
Internal error, calibration issue, settings data lost or current sensor issue.

For the latest and most up-to-date information about the LED blink codes, refer to the Victron Toolkit app. The app is available for Apple and Android. The app can be downloaded from the respective app stores or alternatively follow the download links on our software downloads page.

Page 35

Monitoring

MPPT solar charger manual
7.2. Error codes
In case of an error, an error code will be displayed via VictronConnect, a display, a GX device or on VRM. Each number corresponds with a specific error. For a full list of error codes and their meaning see the appendix: MPPT Solar Charger error code overview [56] 7.3. Monitoring via the VictronConnect App
The VictronConnect App can be used to monitor the solar charger, see its historical values and if there are operational warnings or errors. This chapter explains the solar charger specific VictronConnect App usage. Refer to the general VictronConnect manual for information about the VictronConnect App itself, such as: how to install the app, how to connect to the solar charger, how to update firmware and more.
Where battery voltage is referred in this chapter, a 12V battery is assumed. To arrive at values for 24V, 36V or 48V batteries, multiply the 12V values by a factor of 2, 3 or 4 respectively.
7.3.1. VictronConnect status screen
The status screen displays the solar charger model name together with the live solar charger information.

Smart network
· The presence of the VE.Smart Network symbol indicates that the solar charger is configured for VE.Smart Networking and is receiving battery temperature and/or battery voltage data from the VE.Smart Network.
Solar · The solar gauge shows the solar output in relation to the maximum output power that the solar charger can generate at the set
battery voltage and displays the dynamic real-time value of the solar array output power.
· The solar voltage measured at the solar terminals of the solar charger.
· The solar current flowing from the PV array into the solar charger.
Battery · The battery voltage measured at the battery terminals of the solar charger.
· The current flowing from the solar charger into the battery.
· The battery state indicates the battery charge stage or if external control is active. These are the possible states: Bulk During this stage the solar charger delivers as much charge current as possible to rapidly charge the batteries. When the battery voltage reaches the absorption voltage setting, the solar charger activates the absorption stage.

Page 36

Monitoring

MPPT solar charger manual
Absorption During this stage the solar charger switches to the constant voltage mode, where a pre-set absorption voltage is applied. When the charge current decreases below 2A or if the pre-set absorption time has elapsed, the battery is fully charged and the solar charger will enter the Float stage. Note that when an automatic equalisation is being performed this will also be reported as absorption. Float During this stage the float voltage is applied to the battery to maintain a fully-charged state. When the battery voltage drops below float voltage during at least 1 minute, a new charge cycle will be triggered. External control This will be displayed when another device is controlling the charge behaviour of the solar charger, bypassing its normal charge algorithm. Examples are when the solar charger is controlled by an ESS system or a managed battery.
· In case the charger is not charging a “Why is the charger off?” message will display. When clicking on this message, a new window will open with more information as to why the solar charger is not charging.
Virtual load output · The state of the virtual load output, being switched on or switched off.
7.3.2. VictronConnect history screen
The history screen shows a summary of the data collected over the previous 30 days. Swipe the screen to the right or left to show any of the 30 days.

To switch between portrait or landscape screen presentation click the fragmented square icon, or , at the top left of the screen. The daily log shows: · Solar yield: The energy (Wh) converted for that day.
· Solar Pmax: The maximum power (W) recorded during the day.
· Solar Vmax: The highest voltage (V) from the PV array during the day.
· Battery max and min: The first figure shows the maximum battery voltage (Vmax) for the day. The figure below is the minimum battery voltage(Vmin) for the day.
· Errors: This shows the daily number of errors, if any. To get more information about the error(s), click the orange dot. You may need to slide the display on your device up to see the errors.)
· Lifetime total: This shows the total energy converted by the installation (W and is not re-settable).
· Since reset: This shows how much energy has been converted by the installation since the last reset.
Clicking on any bar (day) in the graph will expand the information. It will show the time and percentage of the total charge time that the solar charger has spend in each Bulk, Absorption and Float charge stage.

Page 37

Monitoring

MPPT solar charger manual
You can use the charge times to see if the PV array is properly sized for your requirements. A system which never reaches the float stage may need more panels. Or perhaps the load should be reduced?
The history can be exported as a comma separated file (CSV) by clicking the three connected dots symbol or the save symbol at the top right of the history screen. The symbol varies, depending on what platform VictronConnect is used.
The history can be reset by clicking the clock with arrow symbol at the top right of the history screen.
7.3.3. VictronConnect error reporting
VictronConnect will indicate active errors while VictronConnect is actively connected to the solar charger. The error will show up in a pop-up window in the status screen together with the error number, name and a short error description. VictronConnect also displays historical errors. To see these errors, navigate to the “History” tab and look at the bottom of each day column. If there is an error, an orange dot will indicate an error.

Active Error and Historical error
7.4. Monitoring via a GX device and VRM
If the solar charger is connected to a GX device, all its data can be accessed via the GX device. The GX device will also notify in case of solar charger alarms or faults. For more information see the GX device manual.

GX device showing alarm notification and historic errors.
If the GX device is connected to Victron Remote Monitoring (VRM) portal, the solar charger can be monitored remotely via the internet.
All solar charger data, alarms and errors can be accessed via the VRM portal and solar charger settings can be remotely changed via the VRM portal with the VictronConnect app.

Page 38

Solar charger alarm logging via VRM

Monitoring

MPPT solar charger manual
8. Warranty
This product has a 5-year limited warranty. This limited warranty covers defects in materials and workmanship in this product and lasts for five years from the date of original purchase of this product. To claim warranty the customer must return the product together with the receipt of purchase to the point of purchase. This limited warranty does not cover damage, deterioration or malfunction resulting from alteration, modification, improper or unreasonable use or misuse, neglect, exposure to excess moisture, fire, improper packing, lightning, power surges, or other acts of nature. This limited warranty does not cover damage, deterioration or malfunction resulting from repairs attempted by anyone unauthorized by Victron Energy to make such repairs. Non-compliance with the instructions in this manual will render the warranty void. Victron Energy is not liable for any consequential damages arising from the use of this product. The maximum liability of Victron Energy under this limited warranty shall not exceed the actual purchase price of the product.

Page 39

Warranty

MPPT solar charger manual
9. Troubleshooting and Support
Consult this chapter in case of unexpected behaviour or if you suspect a product fault. The correct troubleshooting and support process is to first consult the common issues as described in this chapter. Should this fail to resolve the issue, contact the point of purchase for technical support. If the point of purchase is unknown, refer to the Victron Energy Support webpage.
9.1. The controller is not operational
For the controller to be operational it needs to be powered-up. The controller will power up if a battery and/or a PV supply is present. Once the controller is powered up, VictronConnect can be used to: check controller status, to check errors, to update firmware and/or to make or change settings. Once powered up and operational, the controller LED(s) will illuminate or blink and is able to communicate with VictronConnect via Bluetooth (Smart models) or via the VE.Direct port (all models). If the unit does not power up use this chapter to check the possible reasons why the controller is not operational.
9.1.1. Visual check
Before any electrical checks take place it is wise to visually check the solar chargers in case the solar charger has been damaged. · Check for mechanical damage, burn marks or water damage. This damage is not normally covered by warranty. · Inspect the battery terminals and the PV terminals. If there are burn marks on the terminals or if the cables or connectors are
molten refer to paragraph: “PV cable connection burned or melted”. In most cases this damage is not covered by warranty. · Check if there are burn or melting marks on the housing or if there is a burn smell (all very unlikely). If this is the case, lodge a
support request with your Victron dealer or distributor. Depending on the cause, this damage might not covered by warranty.
9.1.2. Battery supply check
Check if the solar charger is receiving battery supply. The normal way to check the battery voltage is via the VictronConnect app, a display or a GX device. However, in this case the controller is not operational so the battery voltage needs to be measured manually. Measure the battery voltage at the solar chargers battery terminals using a multi meter.
V

Measuring battery voltage at the battery terminals of the controller

The reason to measure the battery voltage at the terminals of the solar charger is to rule out potential issues with the wiring, fuses and/or circuit breakers located in the path between the battery and the controller.
Depending on the result of the measurement do the following:

Battery voltage Operational state

No voltage

Not powered

Action to take Restore the battery supply. See chapter: “battery supply issue”

Page 40

Troubleshooting and Support

MPPT solar charger manual

Battery voltage Operational state

Correct voltage

Not powered

Correct Voltage

Powered, but not charging

Action to take
There might be a fault with the controller. Contact your Victron dealer or distributor.
Connect PV supply and check if battery charging starts. If charging does not start, see chapter: ” Batteries are not charged”.

9.2. Batteries are not charged
This chapter lists all possible reasons why the solar charger does not charge the batteries, and the steps you can take to remedy the situation. There are a number of reasons why the solar charger might not charge the batteries. For example: · Issues with the battery, PV panels or system wiring.
· Incorrect settings.
· The solar charger is externally controlled.
· Natural battery behaviour.
In some of these cases the VictronConnect app will show, at the bottom of the status screen, a clickable link with the text “why is the charger off”. If the link is clicked, an explanation will appear as to why the charger is off.

VictronConnect ­ link to “why is the charger off”
9.2.1. Reverse battery polarity
Reverse polarity is when the positive and the negative battery cable have been accidentally swapped. The battery negative has been connected to the positive solar charger terminal and the battery positive has been connected to the negative solar charger terminal.

Page 41

Examples of correct and incorrect (reverse) battery polarity Troubleshooting and Support

MPPT solar charger manual
Be aware that a red cable or positive labelled cable might not necessarily mean that the cable is indeed a positive cable. A wiring or labelling mistake could have been made during installation of the solar charger.
The solar charger is not protected against reverse battery polarity and any damage caused by this is not covered under warranty. Reverse battery polarity can in rare occasions be accompanied with a blown battery fuse (one that is located in the battery cable). But in most cases the ultra-fast internal fuse inside the solar charger will blow to ensure a proper fail-safe situation. This internal fuse will usually blow before the external fuse blows. The internal fuse is located in a non-serviceable area of the solar charger. It is not possible to replace or repair this fuse. This fuse will only blow in case of an internal fault, and replacing the fuse will not fix the internal fault.
Always verify the battery polarity before reconnecting the battery wires to the solar charger.

9.2.2. Reverse PV polarity
As long as the unit is installed within the published specifications, the PV input is protected internally against PV reverse polarity. In case of reverse PV voltage, the solar charger will not indicate an error. The only way to tell is by the following signs: · The controller is not charging the batteries.
· The controller is getting hot.
· The PV voltage is very low or zero Volt.
If this is the case check for reverse polarity using a multimeter by ensuring that the positive PV cable is connected to the positive PV terminal, and the negative cable is connected to the negative terminal.
9.2.3. Battery full
Once the battery is full the solar charger will stop charging or will greatly reduce the charge current. This is especially the case when at the same time the DC loads in the system are not consuming any power from the battery. To find out what the state of charge (SoC) of the battery is, check the battery monitor (if present), or alternatively check what charge stage the controller is in. Also observe that the solar cycle is (briefly) progressing trough these charge stages at the beginning of the daily charge cycle: · Bulk stage: 0-80% SoC
· Absorption stage 80-100% SoC
· Float or storage stage: 100% SoC.
Be aware that it can also be possible that the solar charger thinks the battery is full, while in reality the battery is not full. This can occur when the charge voltages have been set too low, causing the solar charger to prematurely switch to the absorption or float stage.
9.2.4. The charger is disabled
Check the VictronConnect app to make sure the charger has been enabled.

VictronConnect charger enable/disable setting
9.2.5. PV voltage too low
The solar charger will commence charging when the PV voltage is 5V higher than the battery voltage. Once charging has commenced, the PV voltage must remain 1V higher than the battery voltage for charging to continue.
Check the PV and battery voltage
WARNING: Depending on the solar charge controller model, the PV voltage can be up to 450Vdc. Voltages above 50V are generally considered to be dangerous. Check your local electrical safety regulations as to the exact regulations. Dangerous voltages can only be handled by a qualified technician.
1. Use the VictronConnect app, a solar charger display or a GX device to check the battery voltage and PV voltage.

Page 42

Troubleshooting and Support

MPPT solar charger manual

2. In case the above step is not possible, measure the battery and PV voltages at the solar charger terminals using a multi meter instead.

V

V

3. Compare both voltages, the PV voltage needs to be 5V higher than the battery voltage for charging to commence. 4.
Causes of zero or low PV voltage: Not enough solar irradiance into the solar panels: · Night. · Cloud cover or bad weather. · Shading ­ see this shading blog story for more information. · Dirty panels. · Seasonal differences. · Wrong orientation and/or inclination. Problems with a panel or panel wiring: · Mechanical or electrical issue with an individual panel (or multiple panels). · Wiring problems. · Blown fuses. · Open or faulty circuit breakers. · Splitters or combiners issues, or these are used in an incorrect way. PV array design issues: · Solar array wiring configuration mistake – not enough panels in a series string. Reverse PV polarity: · The positive and negative have been swapped when connected to the controller, read next paragraph: “Reverse PV polarity”.
9.2.6. Battery voltage setting too low
The battery will not be charged if the “battery voltage” setting in the VictronConnect App is set at a voltage lower than the actual system voltage. Check that the battery voltage is set properly in the settings of the solar charger. The battery voltage setting has to match that of the voltage of the battery. To access the “battery voltage” setting, navigate to the controller settings in VictronConnect and then click on the “Battery” settings menu.

Page 43

Troubleshooting and Support

MPPT solar charger manual
The “battery voltage” setting is listed at the top of the battery settings menu. Depending on controller model 12, 24, 36 or 48V can be selected. In case the VictronConnect App is not available and a display is used, refer to the display manual on how to check or change this setting.
VictronConnect battery voltage setting
9.2.7. Controlled by an external device
The solar charger can be controlled by an external device. The external device can stop or reduce the charge current to the battery. There are different types of external control: · Managed batteries or an inverter/charger with an external control system system can control the solar charger via a GX device.
The battery dictates if charging is allowed, and when charging is allowed, what charge voltage and currents are used. If external control is active this will be displayed in the VictronConnect App and also on the GX device.

· The BMS of a managed battery can directly turn the charger on or off via a VE.Direct non-inverting remote on/off cable. This cable is connected to the VE.Direct port. The BMS can turn the charger off via this cable. If the charge settings are correctly set and if all battery cells are balanced, the BMS should never disallow charging. The BMS will disallow charging when the cell voltage of one (or more) battery cells is too high or when the low temperature cut off is enabled and the battery temperature has dropped below the temperature threshold.
9.2.8. Battery supply issue
For the solar charger to be fully operational as a battery charger, it needs to be connected to a battery. Although it might look like the solar charger is connected to the battery, it is very well possible that the controller is not receiving the battery supply, there is no voltage at the battery terminals of the solar charger. Possible causes can be: · Loose or missing battery cables.
· Loose cable connections, or badly crimped cable terminals.
· A blown (or missing) fuse in the battery supply cable.
· Open (or faulty) circuit breaker in the battery supply cable.
· Missing or incorrectly wired battery cables.
Battery voltage check
1. Use the VictronConnect app, a connected display or a GX device to find out what the battery terminal voltage of the controller is. If this is unavailable use a multi meter to measure the battery voltage at the terminals of the controller.
V
OR

2. Use a multi meter to measure the voltage at the battery terminals. Page 44

Troubleshooting and Support

MPPT solar charger manual
V
3. Compare the two voltages. 4. If the battery voltage and the controller voltage are not the same, then investigate why this is. Follow the path from the
controller to the battery to investigate what could be the cause.
Battery supply check
1. Check and verify that all cabling is connected correctly, and that no wiring mistakes have been made. 2. Check if all cable connections are tight while taking maximum torque levels into consideration. 3. Check if all cable lugs or cable terminals have been crimped correctly. 4. Check fuses and/or circuit breakers.
If a blown fuse is found, first ensure that the battery polarity has been correctly wired before replacing the fuse. See next paragraph for more information on reverse battery polarity.
9.2.9. PV voltage too high
The PV voltage should never exceed the maximum rated PV voltage of the solar charger. The maximum PV voltage rating is printed on the front or on the side of the housing of the controller, and in the product specification sheets. The solar charger stops charging if the PV voltage exceeds the maximum rated PV voltage. At the same time, it will display an overvoltage error #33, and will fast blink its absorption and float LED. Charging will not recommence until the PV voltage has dropped 5V below the rated maximum voltage. When investigating a high voltage issue, also look at the history of the VictronConnect app, solar charger display or GX device. Check the highest PV voltage for each day (Vmax) and also look for past overvoltage warnings.

VictronConnect: screenshot of an Error #33 and a screenshot of the history indicating an error
Check the open circuit voltage (Voc) rating of the PV array. Ensure that it is less than the maximum rated voltage of the solar charger. Use the MPPT sizing calculator on the solar charger product page. In case the PV array is located in cold climates or if the night temperature drops close to or below 10°C the PV array can output more than its rated Voc. As a rule of thumb, keep an additional 10% safety margin.

Page 45

Troubleshooting and Support

MPPT solar charger manual

An overvoltage event can damage the solar charger, depending on how much the maximum PV voltage was exceeded. This damage is not covered by warranty.
9.3. Batteries are undercharged
This chapter deals with possible reasons why the solar charger is not sufficiently charging the batteries and the steps you can take to check or remedy the situation. Some signs of undercharged batteries: · The batteries take too long to charge.
· The batteries are not fully charged at the end of the day.
· The charge current from the solar charger is less than expected.
9.3.1. Too much DC load
The solar charger does not only charge the batteries, it also provides power for the system’s loads. The battery will only be charged when the power available from the PV panels exceeds the power being drawn by the loads in the system, like lights, fridge, inverter, and so on. If the system battery monitor is correctly installed and configured you can see how much current is going in (or out) of the battery and the solar charger will tell you how much current the solar array is generating. A positive sign alongside the current reading means that current is flowing in to the battery, while a negative sign means that current is being drawn from the battery.
9.3.2. Battery charge voltages are too low
If the battery voltages have been set too low the batteries will not receive a full charge. Check if the battery charge voltages (absorption and float) are set correctly. Consult the battery manufacturers information for the correct charge voltages.
9.3.3. The battery is almost full
The solar charger will reduce its charge current when the battery is almost full. If the state of charge of the battery is unknown, and the current is reducing while the sun is still shining, it can mistakenly be interpreted as the solar charger being faulty. The first current reduction takes place at the end of the absorption stage, when the battery is approximately 80% charged. The current will continue to reduce during the float stage, when the battery is approximately 80 and 100% charged. The float stage starts when the batteries are 100% full. During the float stage the charge current is very low. To find out what the state of charge (SoC) of the battery is, check the battery monitor (if present), or alternatively check the charge stage the solar charger is in. · Bulk: 0-80% SoC
· Absorption 80-100% SoC
· Float or storage: 100% SoC
9.3.4. Battery cable voltage drop
If there is a voltage drop over the battery cables, the solar charger will output the correct voltage, but the batteries will receive a lower voltage. Battery charging will take longer, and this can potentially lead to undercharged batteries. A VE.Smart network can help in case of a cable voltage drop. A Smart Battery Sense or battery monitor measures the battery terminal voltage and sends this via the VE.Smart network to the solar charger. If the battery voltage is less than the solar charge voltage, the solar charger will increase its charge voltage to compensate for the voltage losses. But be aware that in case there is a large voltage drop, the battery cables and cable connection will need to be checked and if there are issue they will needs to be rectified first. A voltage difference has the effect that the battery will be charged with voltages that are too low to. It will take longer to charge the batteries because the charge voltage is too low and there is a loss of charge power. The lost power is caused by heat dissipated over the battery cables. The voltage drop is caused by the following:

Page 46

Troubleshooting and Support

MPPT solar charger manual
· Battery cables with insufficient cross-sectional area · Badly crimped cable lugs or terminals · Loose terminal connections · Bad or loose fuse(s) For more information on cabling issues and voltage drop see the Wiring unlimited book
Battery cable voltage drop check
This check can only be performed if the solar charger is in the bulk charge stage and is charging with full current. 1. Measure the voltage on the battery terminals of the solar charger using the VictronConnect app or a multi meter.
V
OR
2. Measure the battery voltage on the terminals of the battery using a multi meter.
V

3. Compare the two voltages to see if there is a voltage difference.
9.3.5. Temperature difference between solar charger and battery
It is important that the ambient temperatures of the battery and the controller are equal if the solar charger is not receiving battery temperature data.
This chapter does not apply if the solar charger is connected to a VE.Smart Network with a battery temperature measurement or is equipped with a temperature sensor.
The solar charger will measure ambient temperature at the beginning of the day, as soon as power is generated by the solar array. It will temperature compensate the charge voltage according to this temperature measurement. Once the solar charger goes into the float stage it will measure the ambient temperature again and will use that measurement to adjust the voltages again. If there are large ambient temperature difference between solar charger and battery, the battery will be charged at the wrong voltages. An example of this is if the solar charger is located near a window in the sun, and the batteries are located on a cold concrete floor in the shade. Always make sure that the ambient conditions are equal for both the solar charger and the battery.
9.3.6. Insufficient solar
Check if the solar charger reaches the float charge stage each day.

Page 47

Troubleshooting and Support

MPPT solar charger manual
To investigate look at the history tab in the VictronConnect app. The histogram displays how long the batteries have been charged in the Bulk, Absorption and Float stage each day, for the last 30 days. If you click on one of the histogram columns you will see a breakdown of the charge stages. You can use the charge times to see if the PV array is properly sized for your requirements. A system which never reaches the float stage could have the following issues: · Not enough solar panels · Too much load · A problem with the array causing it to have a reduced power output. · For more potential reasons see paragraph: “PV power or yield less than expected” Please note that above information does not apply to an ESS system. An ESS system will always be in the bulk charge stage while grid is connected.

System spending all its time in bulk with breakdown of charge stages – System in bulk and absorption
9.3.7. Wrong temperature compensation setting
If the temperature compensation coefficient is set incorrectly, the batteries can be undercharged or be overcharged. The temperature compensation can be set via VictronConnect or via a display. To find out the correct temperature compensation coefficient setting for your battery, refer to the battery documentation. When in doubt use the default value of -64.80mV/°C for lead acid batteries and disable the temperature compensation setting for lithium batteries.
9.3.8. Battery charge current too low
Check the “Max charge current” setting in the VictronConnect app or via the display. If the “Max charge current” has been set too low, it will take longer to charge the batteries and/or the batteries will not be fully charged at the end of day.
9.4. Batteries are overcharged
Batteries that are being overcharged are very dangerous! There is a risk of battery explosion, fire or acid leakage. Do not smoke, create sparks or have open flames in the same room as where the batteries are located.

Overcharging batteries will cause battery damage and can be caused by: · Incorrect charge voltage settings. · Battery voltage setting too high. · Applying equalization while the battery is not suitable for equalization. · High current and undersized batteries. · Battery faults. · Too high current, while the battery is not accepting charge anymore because of aging or prior mistreatment.
9.4.1. Battery voltage setting too high
If the “battery voltage” setting in the VictronConnect App has been set to a voltage higher than the actual system voltage, the battery will be overcharged.

Page 48

Troubleshooting and Support

MPPT solar charger manual
The solar charger automatically detects the battery voltage on first install and after the self-detection is disabled. This can become a problem if a solar charger that came out of a 24V system is now used in an 12V system. In that scenario it will not detect that the system has changed and will keep charging with 24V battery charge voltages, while the connected battery is a 12V battery and the 12V battery will be overcharged. Some background on why this is: In the very early days, the solar charger would always automatically detect the battery voltage, but this was problematic in case the battery was disconnected often, for example by a BMS. This feature has since been changed to detect the voltage only once on first install. To check the “battery voltage” setting use the VictronConnect App or a connected display. If set incorrectly, set it to the correct battery voltage.
9.4.2. Battery charge voltages too high
If the battery charge voltages are set too high this will cause the batteries to overcharge. Check if all the battery charge voltages (absorption and float) are set correctly. The charge voltages have to match the recommended voltages as stated in the battery manufacturers documentation.
9.4.3. Battery unable to deal with equalization
During equalization the battery charge voltage will be quite high and if the battery is unsuitable to be equalized, the battery will be overcharged. Not all batteries can be charged with equalization voltages. Check with the battery manufacturer if the battery you are using needs a periodic equalizing charge. Generally speaking, sealed batteries and lithium batteries cannot be equalized.
9.4.4. Battery old or faulty
A battery that is at the end of its service life or has been damaged by incorrect use, can be prone to being overcharged. A battery contains a number of cells that are connected in series. When a battery is old or has been damaged, a likely scenario is that one of these cells is not operational anymore. When the faulty battery is charged, the damaged cell will not accept charge and the remaining cells will receive the broken cell’s charge voltage and thus will be overcharged. To fix this, replace the battery. In case of multiple battery system replace the whole battery bank. It is not recommended to mix batteries of different ages in one battery bank. It is hard to tell what has exactly happened to a battery during its lifetime. The solar charger will keep 30 day of battery voltage history. If the system also contains a battery monitor, or if the system is connected to VRM, the battery voltages and the cycle history of the battery can be accessed This will give a complete picture of the battery history and it can be determined if the battery is near the end of its service life or has been abused.

Page 49

VictronConnect app showing BMV battery monitor history Troubleshooting and Support

MPPT solar charger manual
To check if the battery is close to its cycle life:
1. Find out how many charge and discharge cycles the battery has been subjected to. Battery lifetime correlates to the number of cycles.
2. Check how deep the battery has been discharge on average. A battery will last for less cycles if deeply discharged, compared to more cycles if discharged less deep.
3. Refer to the battery data sheet to find out how many cycles at what average discharge the battery is capable of. Compare this with the battery history and determine if the battery is near the end of its service live.
To check if the battery has been misused:
1. Check if the battery has been totally discharged at all. Total and very deep discharge will damage a battery. Check the battery monitor setting history on the VRM portal. Look for the deepest discharge, the lowest battery voltage and the number of full discharges.
2. Check if the battery has been charged with a too high voltage. Very high charge voltage will damage the battery. Check the maximum battery voltage and the high voltage alarms in the battery monitor. Check if the measured maximum voltage has exceeded the battery manufacturer recommendations.
9.5. Solar issues
This chapter deals with the remaining potential solar issues that were not already discussed in the earlier chapters.
9.5.1. PV reverse current too high
Overcurrent does not necessarily damage the solar charger, but it will cause damage if the array produces too much current while, at the same time, the array has been connected in reverse polarity to the solar charger. Damage due to overcurrent is not covered under warranty. Refer to the solar chargers technical specifications for the maximum PV short circuit power current rating.
9.5.2. PV yield less than expected
Check the solar charger history in the VictronConnect app. Check the total maximum power (Pmax) for each day. Does this match the array power? To find the potential solar yield per day for a specific PV array size in a specific geographical location, use the MPPT sizing calculator on the solar charge controller product page. These are some of the reasons why the array is generating less power than expected: · Low sun angle, seasonal differences or morning/evening.
· Cloud cover or bad weather.
· Shading from trees or buildings.
· Dirty panels.
· Incorrect orientation and/or inclination.
· Broken or faulty solar panel(s).
· Issues with wiring, fuses, circuit breakers, wiring voltage drop.
· Bad splitters or combiners, or these are used in an incorrect way.
· Part of the PV array not working.
· PV array design issues.
· Solar array configuration mistakes.
· The batteries are too small, or getting older, and have a reduced capacity.

Page 50

Troubleshooting and Support

MPPT solar charger manual

VictronConnect history Pmax
9.5.3. Full rated output not reached
There are a few reasons why the solar charger is not reaching its full rated output.
Some of these reasons have already been explained in the the chapter: “The batteries take too long to charge, are undercharged or charge current less than expected”. Some additional reasons are explained in this paragraph.
PV array too small If the PV array power rating is less than the solar charger nominal power rating, the solar charger cannot output more power than the connected solar array can provide.
Temperature above 40°C When the solar charger heats up, eventually the output current will derate. When the current is reduced naturally the output power will reduce as well.
The controller is operational up to 60°C, with a full rated output up to 40°C.
In case the solar charger heats up quicker than expected, pay attention to the way it has been mounted. Mount it in such a way that the generated heat can dissipate.
Ideally mount the solar charger on a vertical surface with the terminals facing downwards.
If the solar charger is located in a closed enclosure, such as a cabinet, make sure that cold air can enter and hot air can leave the enclosure. Mount vents in the enclosure.
For very hot environments consider mechanical air extraction or provide air conditioning.
9.5.4. Max PV output power relates to battery voltage
The output current of the solar charger is current limited to its rated current. This means that the output power will vary, depending on the voltage of the battery.
For example: A 75/15 solar charger has an output current rating of 15A. This is the current that is going into the battery. This means that if the solar charger is connected to a 12V battery you will get less power into your battery than with a 24V battery.
· For a 12V battery this is 15A x 12V = 180W.
· For a 24V battery this is 15A x 24V = 360W.
So, although a 360 W panel is connected to the solar charger, it will not be able to output the same power into a 12V battery than it will when connected to a 24V battery.

Page 51

Troubleshooting and Support

MPPT solar charger manual

Example of differences in output power at different battery voltages
9.5.5. Mixed PV panel types
It is not recommended to connect a mix of different PV panel types to the same solar charger. Only use solar panels that are the same brand, type and model.
9.5.6. PV connections burned or melted
Burned or melted PV cables or connections are generally not covered under warranty. In most case this is due to any of the following reasons: Solar cable · Cables with rigid core wire or rigid strands used. · Cables where the core wire has been soldered. · Cable too thin – remember that the current will be higher when the PV voltage is lower. For more information on cable thickness
see the Wiring Unlimited book. Screw terminals · Loose screw connection. · Cable insulation inserted too deep into the connector. · Cables with rigid core wire or rigid strands used. · Cables where the core wire has been soldered.
9.5.7. MC4 connectors wrongly connected
For a detailed explanation on how to connect MC4 connectors, MC4 splitters and MC4 combiners, see the Wiring unlimited book, chapter 4.10: “Solar panels”.
9.5.8. Optimisers cannot be used
Do not use solar panels with optimisers together with the solar charger. Nearly all optimisers contain an MPPT or other tracking mechanisms and this interferes with the MPPT algorithm in the solar charger.
9.5.9. Earth fault detection missing
This solar charger is not equipped with an earth fault relay or an earth fault warning circuit. Use an external ground fault relay or ground fault detector.
9.5.10. Ground current
The system should not have a current flowing to ground under normal operation. If a ground current is detected, first investigate all the equipment connected to that system and check for ground faults. Next, check how many connections to ground the system has. There should only be a single point in the system connected to ground . This should be at the battery.

Page 52

Troubleshooting and Support

MPPT solar charger manual
For more information on system grounding, see chapter 7.7: “System grounding” in the Wiring Unlimited book. The solar charger is non-isolated, the minus of the PV input is at the same potential as the minus of the battery output.
9.6. Communication issues
This chapter describes issues that might arise when the solar charger is connected to the VictronConnect app, other Victron devices or third-party devices.
9.6.1. VictronConnect issues
For a full troubleshooting guide on the VictronConnect app see the VictronConnect manual.

9.6.2. VE.Direct port communication issues
These are not common and if this occurs it is probably due to one of these issues listed in this paragraph.
Physical cable connector or data port issues Try a different VE.Direct cable and see if the unit will now communicate. Is the connector inserted properly and deep enough? Is the connector damaged? Inspect the VE.Direct port, are there bent pins? If this is the case, use long nose pliers to straighten the pins, while the unit is unpowered.
VE.Direct communication issues To check if VE.Direct communication is operating correctly, connect the solar charger to a GX device and check if the controller shows up on the GX device’s list. If it does not show up, check that TX port function in VictronConnect is set to “Normal communication”.
VE.Direct TX port issues Check the “TX port function” setting in VictronConnect. Does the set function match the application it is being used in. To test if the TX port is operational check its functionality using a TX digital output cable.
VE.Direct RX Port issues Check the “RX port function” setting in VictronConnect. Does the set function match the application it is being used in. To test if the RX port is operational check its functionality using a VE.Direct non-inverting remote on/off cable.
9.6.3. VE.Smart communication issues
A VE.Smart Network is a wireless communication network between several Victron products using Bluetooth. In case of issues with a VE.Smart Network refer to the Smart Network manual.
9.6.4. Bluetooth issues
Please note that it is highly unlikely that the Bluetooth interface is faulty. The problem is most likely caused by something else. Use this chapter to quickly rule out some of the common causes of Bluetooth issues.
For a full troubleshooting guide see the VictronConnect manual.
· Check if the solar charger is equipped with Bluetooth Only SmartSolar models

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

victron energy User Manuals