PureWave Inverter
Pure Sine Wave 120 VAC (2kVA)
The La Marche PureWave, Pure Sine Wave inverter built with CSA and UL compliance, which makes this Inverter/Charger ideal for the Marine market. The LCD display allows to monitor and configure the system, making it a flexible Inverter/Charger for various types of loads and batteries. Its surge capability allows it to start complex loads, everything in a light and compact enclosure.
Standard Features
120 VAC Output
12 or 24 VDC Input
LCD Display
LED Indicators
Solid Green | Output is powered by shore power |
---|---|
Solid Green | Output is powered by battery |
Solid Red | Fault occurs in the inverter |
Flashing Red | Warning condition occurs in the unit |
Built in Charge
Pure Sine Wave
90% Efficiency
Wall Mount
UL 458
Transfer Times
Shore to Inverter | <15 ms |
---|---|
Inverter to Shore | <10 ms |
Specifications
MI-2K-12V-A6 | MI-2K-24V-A6 |
---|
DC Input
Nominal DC Input Voltage| 12 VDC| 24 VDC
Normal Range DC Input Voltage Range| 11 – 17 VDC| 22 – 30 VDC
DC Under Voltage Shutdown Level| 10.5 VDC (Default)| 21 VDC (Default)
DC Under Voltage Shutdown Recovery Level| 13.1 VDC (Default)| 26.2 VDC
(Default)
DC Over Voltage Shutdown Level| 18 VDC| 32 VDC
| AC Output
Output Voltage Waveform| Pure Sine Wave
Nominal AC Output Voltage| 120 VAC L-N
Total Harmonic Distortion Voltage (% THD)| < 5% THD of Fundamental (Voltage)
< 10% THD Full Input Voltage Range (Full Load)
< 20% for 230V Model when DC Input is in Range 16-18VDC
Output Frequency| 60 Hz ±1 Hz
Continous Output Power
| Rated Power (-20°C to 40°C) 2000 W / 000| Ambient Temperature at Full Load
40°C| Derated Power at Maximum Ambient (60°C) 1700 W
Surge Output Rating| **
Load Power Fact| 0.6 to 1.0 (lead or lag)
Optimum Efficiency| >91%
No Load Power Consumption @ Nominal Voltage| <25 W
SPS Off Power Consumption @ Nominal Power| <0.5 W
AC Input|
AC Input Voltage| 120 VAC ± 2 V
AC Input Voltage Range| 85 – 140 VAC
Normal Operating AC Input Voltage Range| 100 – 130 VAC
AC Input Frequency| 60 ± 5 Hz (Default), 50 ± 5 Hz
Mechanical Specification
Dimensions (L x W x H)| 370 x 275 x 100
Environmental**
Operating Ambient Temperature Range| -20 to 40°C
Maximum Operating Temperature| + 0°C
Storage Temperature Range| -40 to 95°C
Relative Humidity| 5% ~ 95% non-condensing
Cooling| Force Cooling
EMC and Safety| ITS listed and c(ETL)us marked complies with CSA C22.2 No.
107.1, UL458 with marine supplement (optional drip shield required) ABYC E-11,
A-31, A-32
Electromagnetic Compability| Complies with FCC Part 15, Subpart B, Class B and
with CAN ICES-3 (B) Emissions