La MARCHE P25-DSPUREWAVE-1 PureWave Inverter Instructions

June 12, 2024
La Marche

La MARCHE - LOGO PureWave Inverter
Pure Sine Wave 120 VAC (2kVA)La MARCHE P25-DSPUREWAVE-1 PureWave
Inverter

The La Marche PureWave, Pure Sine Wave inverter built with CSA and UL compliance, which makes this Inverter/Charger ideal for the Marine market. The LCD display allows to monitor and configure the system, making it a flexible Inverter/Charger for various types of loads and batteries. Its surge capability allows it to start complex loads, everything in a light and compact enclosure.

Standard Features

120 VAC Output
12 or 24 VDC Input
LCD Display
LED Indicators

Solid Green Output is powered by shore power
Solid Green Output is powered by battery
Solid Red Fault occurs in the inverter
Flashing Red Warning condition occurs in the unit

Built in Charge
Pure Sine Wave

90% Efficiency
Wall Mount
UL 458

Transfer Times

Shore to Inverter <15 ms
Inverter to Shore <10 ms

La MARCHE P25-DSPUREWAVE-1 PureWave Inverter - PARTS 1

Specifications

MI-2K-12V-A6 MI-2K-24V-A6

DC Input
Nominal DC Input Voltage| 12 VDC| 24 VDC
Normal Range DC Input Voltage Range| 11 – 17 VDC| 22 – 30 VDC
DC Under Voltage Shutdown Level| 10.5 VDC (Default)| 21 VDC (Default)
DC Under Voltage Shutdown Recovery Level| 13.1 VDC (Default)| 26.2 VDC (Default)
DC Over Voltage Shutdown Level| 18 VDC| 32 VDC
| AC Output
Output Voltage Waveform| Pure Sine Wave
Nominal AC Output Voltage| 120 VAC L-N
Total Harmonic Distortion Voltage (% THD)| < 5% THD of Fundamental (Voltage)
< 10% THD Full Input Voltage Range (Full Load)
< 20% for 230V Model when DC Input is in Range 16-18VDC
Output Frequency| 60 Hz ±1 Hz


Continous Output Power

| Rated Power (-20°C to 40°C) 2000 W / 000| Ambient Temperature at Full Load 40°C| Derated Power at Maximum Ambient (60°C) 1700 W
Surge Output Rating| **
Load Power Fact| 0.6 to 1.0 (lead or lag)
Optimum Efficiency| >91%
No Load Power Consumption @ Nominal Voltage| <25 W
SPS Off Power Consumption @ Nominal Power| <0.5 W
AC Input|
AC Input Voltage| 120 VAC ± 2 V
AC Input Voltage Range| 85 – 140 VAC
Normal Operating AC Input Voltage Range| 100 – 130 VAC
AC Input Frequency| 60 ± 5 Hz (Default), 50 ± 5 Hz
Mechanical Specification
Dimensions (L x W x H)| 370 x 275 x 100
Environmental**
Operating Ambient Temperature Range| -20 to 40°C
Maximum Operating Temperature| + 0°C
Storage Temperature Range| -40 to 95°C
Relative Humidity| 5% ~ 95% non-condensing
Cooling| Force Cooling
EMC and Safety| ITS listed and c(ETL)us marked complies with CSA C22.2 No. 107.1, UL458 with marine supplement (optional drip shield required) ABYC E-11, A-31, A-32
Electromagnetic Compability| Complies with FCC Part 15, Subpart B, Class B and with CAN ICES-3 (B) Emissions