Product Information
The ChlorPlus Protect 10 Water Filtration System is designed to reduce the concentration of specific substances in water. It has been tested according to NSF/ANSI Standard 53 and meets the requirements for reducing Perfluorooctanoic Acid (PFOA) and Perfluorooctane Sulfonate (PFOS) to a concentration less than or equal to the permissible limit. The system has an average reduction of 98.20% for the listed substances. It operates at a flow rate of 1 gallon per minute (3.79 liters per minute) and has a capacity of 1,000 gallons (3,785.41 liters) or 12 months.

Product Usage Instructions

Installation

  1. Ensure that the water supply is turned off before starting the installation.
  2. Connect the system to the water supply using the provided inlet/outlet connections. For brass fittings, tighten the nut snugly about 1/2 turn with a wrench.
  3. Turn on the water supply and check for any leaks. If leaks persist, turn off the water supply and contact Pentair Technical Support at 1.800.279.9404.

Troubleshooting Leaks
If there are leaks between the cap and bottom of the filter housing:

  1. Turn off the water supply and press the red pressure-relief button.
  2. Remove the bottom of the housing.
  3. Clean the O-ring and O-ring groove located beneath the threads of the housing.
  4. Lubricate the O-ring with silicone lubricant and place it securely into the groove.
  5. Screw the bottom of the filter housing onto the cap and hand-tighten it. Do not over-tighten.

If there are other leaks in the system, turn off the water supply and contact Pentair Technical Support at 1.800.279.9404.

Replacement Parts
For replacement parts, contact your nearest Pentair dealer or call 1.800.279.9404. The following replacement parts are available:

  1. 151039 – Pressure-relief button kit
  2. 154101 – Blackcap (W/PR 3/4)
  3. 151120 – O-ring, cap
  4. 153019 – Blue housing
  5. 655226-43 – ChlorPlus Protect 10 cartridge
  6. 151011 – UB-1KIT mounting bracket kit
  7. 150295-06 – SW-2 housing wrench

Precautions

  • Do not use the system with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
  • Protect the filter against freezing, as it can cause cracking and water leakage.
  • Ensure that the rubber O-ring is properly seated in the groove below the threads of the housing to prevent water leaks.
  • Replace the bottom of all plastic housings every 10 years for opaque to prevent costly repairs or water damage. Date the bottom of any new or replacement housing to indicate the next recommended replacement date.

For more information on product warranties, visit pentair.com/assets /residential-filtration-warranty. For any further assistance, please contact Pentair Customer Service at 800.279.9404 or email
tech-support@pentair.com.

OPERATING SPECIFICATIONS

  • Pressure Range: 30–125 psi (2.1–8.6 bar)
  • Flow Rate: 1 gpm (3.78 Lpm)
  • Capacity: 1,000 gallons (3,785 L)
  • Temperature Range: 40–100°F (4.4–37.7°C)

PARTS INCLUDED

  • 10″ filter housing
  • ChlorPlus Protect 10 cartridge
  • Filter housing cap
  • O-ring
  • Mounting bracket kit
  • Screw kit
  • Housing wrench

TOOLS AND MATERIALS REQUIRED (not included)

  • Appropriate fittings and pipe to install the filter
  • Plumber’s tape
  • File
  • Pencil
  • Phillips head screwdriver
  • Adjustable wrenches (2)
  • Pipe cutters or hacksaws

PRECAUTIONS

WARNING: Do not use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
CAUTION: The filter must be protected against freezing, which can cause cracking of the filter and water leakage.
CAUTION: The rubber O-ring provides a watertight seal between the cap and the bottom of the housing. It is important that the O-ring be properly seated in the groove below the threads of the housing or a water leak could occur.
CAUTION: Because of the product’s limited service life and to prevent costly repairs or possible water damage, we strongly recommend that the bottom of all plastic housings be replaced every 10 years for opaque. If the bottom of your housing has been in use for longer than this period, it should be replaced immediately. Date the bottom of any new or replacement housing to indicate the next recommended replacement date. The ChlorPlus Protect 10 system is certified by IAPMO R&T against NSF/ANSI 53 for the reduction of perfluorooctanoic acid (PFOA) and perfluorooctane sulfonate (PFOS

PERFORMANCE DATA SHEET

This system has been tested according to NSF/ANSI Standard 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water exiting the system, as specified in NSF/ANSI Standard 53. Testing was performed under standard laboratory conditions; actual performance may vary. Flow Rate = 1 gpm (3.79 L/min); Capacity = 1,000 gallons (3,785.41 L) or 12 months

Substance

|

Influent Challenge Concentration

|

Max. Permissible Product Water Concentration

|

Reduction Requirements

|

Average Reduction

---|---|---|---|---
Standard 53
Perfluorooctanoic Acid (PFOA) and Perfluorooctane Sulfonate (PFOS)| 0.0015 mg/L ± 10%| 0.00007 mg/L| n/a| 98.20%

TROUBLESHOOTING

Leaks:
Between Cap and Bottom of Filter Housing:

  1. Turn off the water supply and press the red pressure-relief button. Remove the bottom of the housing.
  2. Clean the O-ring and O-ring groove (located directly beneath threads of housing). Lubricate the O-ring with silicone lubricant and replace it securely into the groove. Screw the bottom of the filter housing onto cap and hand-tighten it. Do Not Overtighten.

On Inlet/Outlet Connections:

  1. Turn off the water supply. For brass fittings, tighten the nut snugly about 1/2 turn with a wrench.
  2. Turn on the water supply. If leaks persist, or if there are other leaks in the system, turn off the water supply. Call Pentair Technical Support at 1.800.279.9404.

REPLACEMENT PARTS

PENTAIR-Chlorplus-Protect-10-Water-Filtration-System-
fig-1

  1. 151039 Pressure-relief button kit
  2. 154101 Blackcap (W/PR 3/4″)
  3. 151120 O-ring, cap
  4. 153019 Blue housing
  5. 655226-43 ChlorPlus Protect 10 cartridge
  6. 151011 UB-1KIT mounting bracket kit
  7. 150295-06 SW-2 housing wrench
  8. For replacement parts, contact your nearest Pentair dealer or call 1.800.279.9404.

NOTE:

  • For cold water use only
  • Do not install where the system will be exposed to direct sunlight.
  • Make certain that installation complies with all state and local laws and regulations.
  • The contaminants or other substances removed or reduced by the selected filter cartridge are not necessarily in your water. Ask your local water municipality for a copy of their water analysis, or have your water tested by a reputable water testing lab.
  • After prolonged periods of non-use (such as during a vacation), it is recommended that the system be flushed thoroughly. Let water run for five (5) to six (6) minutes before using.
  • The filter cartridge used with this system has a limited service life. If there are any changes in taste, odor, color, and/or flow of the filtered water, please replace the filter cartridge.
  • Spent adsorption media will not be regenerated and used.

INSTALLATION
NOTE:

  • Please read all instructions, specifications, and precautions before installing and using this filter.
  • For installation on standard 1/2″ or 3/4″ main water line (galvanized, copper or plastic pipe).
  • Only use plumber’s tape for fitting housing connections.
  • Install the filter cartridge in the filter housing according to the filter cartridge replacement instructions on p.4 before proceeding with the installation. See Filter Cartridge Selection Guide on p.5 to determine the best filter cartridge for your filtration needs.
  • Install filter cartridge after water meter or pressure tank.
  • Numbered diagrams correspond with numbered steps.
  1. [A] Turn off the cold water supply, and open the nearest faucet [B] to release pressure in pipes before starting installation. [C] Apply about 6″ of plumber’s tape in a clockwise direction to the pipe threads of each adapter.PENTAIR-Chlorplus-Protect-10-Water-Filtration-System-2

  2. [D] If the mounting bracket is to be used, use the bracket as a template to mark screw locations on the wall. Insert mounting screws into the wall. [E] Leave a space for the thickness of a nickel (2mm) between the head of the screw and the wall-to-slip bracket onto the screws. Then place the bracket over the cap and align it with the inlet and outlet ports.
    NOTE : Allow 1 1/2″ clearance below the housing to enable filter cartridge changes. [F] Assemble all fittings. Start adapters into the cap by hand. Use a wrench to tighten firmly. DO NOT OVERTIGHTEN. About one thread should remain visible. [G] Remove compression nuts from
    fittings.
    NOTE : If using a mounting bracket, be sure to insert fittings through the bracket before threading into the filter cap. [H] Measure length across assembled fittings and subtract 1″ for 3/4″ pipe or 1 1/2″ for 1/2″ pipe. Mark the section of pipe to be removed.
    NOTE : Approximately 6″ will be removed for 3/4″ pipe and 5 1/4″ for 1/2″ pipe. [I] Using a pipe cutter or hacksaw, cut pipe and remove the marked section. File or sand sharp edges on the remaining pipe.

  3. [J] Slip brass compression nut and brass ferrule [K] onto each end of 3/4″ pipe. [L] If installing on 1/2″ pipe, substitute rubber ferrule for the brass ferrule.

  4. [M] Align filter assembly with ends of pipe, making certain cap opening marked “IN” is facing your incoming water supply [N]. It will be necessary to spread ends of pipe apart to install filter assembly. Using two (2) adjustable wrenches, hold inlet adapter securely with one wrench and tighten it with a second wrench. Repeat the process for an outlet adapter.
    NOTE: If using a mounting bracket, be sure to slip the bracket over the screws in the wall
    (see step 2). [O] Slowly turn on the water supply to allow the filter to fill with water. PENTAIR-Chlorplus-Protect-10-Water-Filtration-
System-3

  5. Depress red pressure-relief button on top of cap to release the trapped air.

  6. Check for leaks. [Q] Open the nearest faucet and flush the filter cartridge for five (5) minutes.
    CAUTION : If water pipes are used to ground electrical systems, appliances, or phones, be sure to install a jumper wire.

  7. Contact a qualified electrician with any questions about your home’s electrical system.

FILTER CARTRIDGE REPLACEMENT
WARNING: Use safety glasses when handling household bleach to prevent bodily injury. Follow the bleach manufacturer’s instructions when handling bleach.

  1. Turn off cold water supply, open the nearest faucet.
    NOTE: This will shut off all water flow within the household. Fill a bucket with water to clean the housing after it has been removed.

  2. Depress red pressure-relief button to release pressure.PENTAIR-Chlorplus-Protect-10-Water-Filtration-System-4

  3. Remove the bottom of the housing by turning it clockwise.

  4. Locate and remove the large O-ring, wipe clean of lubricant and set aside. Discard used cartridge. Rinse out the bottom of the housing and fill 1/3 full with water. Add two (2) tablespoons of bleach and scrub the cap and bottom of the housing with a non-abrasive sponge or cloth. Rinse thoroughly. Lubricate the O-ring [4] with clean silicone grease. Insert the O-ring back into the groove and smooth into place with a finger.
    NOTE: This step is important to ensure proper housing seal. Make sure the O-ring is seated level in the groove. Insert a new cartridge [5] over the standpipe in the bottom of the housing.

  5. Screw the bottom of the housing onto the cap and hand-tighten it. DO NOT OVERTIGHTEN. Make certain cap standpipe slips into the cartridge.

  6. Slowly open the cold water supply 1/4‑turn counterclockwise to allow the filter to fill with water.

  7. Depress red pressure-relief button (if present) to release the trapped air. Flush the cartridge for five (5) minutes before use. Flush again for 10 minutes before using water.