ITEMIZED PARTS LIST

BOX 1: NC-X3 Air Conditioning Unit

ID Qty Part Name
1 NC-X3 Air Conditioner ****

BOX 2: Vent Plate

| 1| Vent plate with 4 dir. vents and LCD control|
---|---|---|---
| 1| Foam filter air separator (Option A or B)|
| 2| Crossbars|
| 9| Black (preferred) vent plate self-drilling screws|
| 9| Silver (alternative) vent plate screws|
| 10| Washers|
| 4| Mounting bolts|
| 4| Mounting nuts|
| 10| Sticky plates for zip ties|
| 20| Zip ties (10 large + 10 small)|
| 1| Remote Control|

BOX 3: Wiring Kit

| 1| Wiring harness (15 ft)|
---|---|---|---
| 1| Bagged Anderson clip and metal connectors|
| 1| Bagged Victron fuse holder and 125A fuse|
| 1| Tube of BetaSeal U428+HV and plastic tip|
| 1| Sealed Bag with 2 awg 5/16” lugs, 3 red and 1 black heat shrink 3/4“, and 1 thread locker|
| 1| Foam gasket (A) or Premium Gasket (B)|
Part| 1| Leveling strip|
| 1| Foam filter air separator (Option A or B)|
| 1| Cardboard template|

Instruction

IMPORTANT SAFETY INSTRUCTIONS

This guidebook contains safety guidelines and instructions that can aid in reducing or eliminating the risk of accidents and injuries.

A. Recognizing Safety Information
The safety alert symbol is utilized to notify potential physical injury hazards. To avoid possible injury or death, follow all safety messages that come after this symbol.

B. Understanding Signal Words
Signal words identify safety and property damage messages and indicate the degree of hazard seriousness.

WARNING is used for hazardous situations that could result injury (including death, severe, moderate or minor injury if not avoided.

NOTICE is used for situations that could result in AC unit or vehicle damage or unnecessary complications in the installation process.

HELPFUL TIP is used for useful information or best practices.

C. Supplemental Directives
To avoid potential injury and even death, read and follow all of the safety information and instructions. Read and comprehend these instructions before installing, using, servicing, or maintaining this AC unit. Poor installation, operation, servicing, or maintenance of this AC unit can result in severe injury. Follow all instructions.

The installation must comply with all applicable local and national codes, including the latest edition of the following standards

USA

  • ANSI/NFPA70, National Electrical Code (NEC)
  • ANSI/NFPA1192, Recreational Vehicle Code

CANADA

  • CSA C22 1. Parts I & II, Canadian Electrical Code
  • CSA Z240 RV Series, Recreational Vehicles

D. General Safety Messages
WARNING – Failure to follow the subsequent warnings could lead to death or serious injury

  • A qualified service technician MUST install or service this product.
  • Do NOT modify this product in any way. Modifications can be extremely dangerous and void any warranties.
  • Do NOT add any devices or accessories to the AC unit unless specifically authorized in writing by Nomadic Cooling Co.

NC-X3 SPECIFICATIONS

Instruction

INSTALLATION STEPS

Mark your 14”x 14” rooftop
opening. Cut from the exterior of your vehicle.

Never cover AC top fan.
When determining AC unit location, be sure to allow for the hood/cover when positioned on the roof.
Make sure there is no electrical or other encumbrances in the way.
Do not cut into structural beams.

Make sure the planned opening is centered from all four sides. This gives the best chance for easy installation.
Instruction

Use painter’s tape and a permanent\ marker to draw your 14”x 14” cutline.
Make multiple passes with the marker.
If you make a mistake replace thetape and try again. Measure repeatedly to make sure your lines create a perfect 14”x 14” square.

Drill each corner of your markings through the roof. This will make it easier to detect the location of your 14”x 14” opening from the underside of your roof.
Instruction

Use a 1/8” drill bit for corner holes.

Cut on your lines using a jig saw, nibbler or cutting wheel.
Instruction

Use a sander or file to smooth out the rough edges after cutting
Instruction

Paint around the edges of the cut roof opening to prevent rust. You can use any color rust-preventative paint.
Instruction

Remove tape and clean surface.
Remove Nomadic Cooling 14”x 14” waterproof gasket from packaging
Instruction

Make sure area/paint is clean, dry and clear of all debris. Use alcohol wipes or PrepSol to remove oil or wax from vehicle roof. If your AC unit included a premium gasket, skip to step 9.

If placing gasket over a high or uneven roof surface, remove small amounts of the 14”x 14” gasket to match roof contours.
Instruction

Use blade to cut away gasket if needed.

Place the gasket sticky side down.

Apply window weld around 14”x 14” gasket, after sticking it down.
Instruction

Place AC unit on roof over 14”x 14” gasket gently. Measure side-to-side until unit is centered on all four sides. Be careful not to puncture, rip or tear the gasket with AC unit’s mounting bolts. Do not put adhesive on top of gasket. Do not damage electrical components when placing unit.

From inside the vehicle add support brackets to mounting bolts to attach AC unit to the roof. Hand tighten all four bolts then 1/4 turn more (about 4 lbs. of torque). Do not use electric drills. Do not over-tighten mounting bolts. Bolts will rotate if over torqued, and may break from base plate. Over- tightening will void warranty.

If you purchased the optional internal trim piece, it should be placed between the roof and the AC unit before brackets are added.
Instruction

Put the two washers on the M8 bolt and thread the first nut until crossbar is secured. Tighten until the gasket is compressed slightly. No light should be visible. AC unit will create pressure.
Instruction

When securing AC unit to the vehicle, increased compression of the gasket will level the unit against the roof. Gasket is used for vibration absorption. It is very high density and can’t be compressed more than 10%. Use gasket tension to control AC unit’s distance from roof surface.

A/C should be resting on gasket, not vehicle
Instruction

Over compression of the unit to the roof may cause the internal fan to rub against the fan housing. Be sure the fan blades rotate freely prior to starting the unit.

Connect DC power wires to unit. “Quick Connection to DC Wiring Harness” included.
Instruction

Make sure wiring is appropriately sized and is no smaller than 2AWG. Make sure the fuse is installed and appropriately sized.
Install and connect LCD panel before connecting to power to avoid blowing internal fuse! A 125A fuse/breaker is mandatory between your power source and the air conditioning unit.
Instruction

Attach LCD control panel and AC wiring harnesses.
Instruction

Attach thermostat wires to control panel wiring harness. Condenser is always to the left of the black wire. Be careful not to break these wires. See electrical wiring diagram on page 12.

Use the foam separator (Option A or B) to properly separate hot air from cold air as it enters and exits the AC unit.
Instruction

For deeper roofs, you can double the foam separators by stacking them on each other.

Instruction

Test all connections between thepower source and the unit for excessive heat during normal operations.

Install faceplate. Use self-drilling screws to firmly secure your faceplate to your final roof panel/wall.

Exploded NC-X3 Components
Instruction

Electrical Wiring Diagram

Instruction