hager TRE500 Motion Detectors Instruction Manual

June 12, 2024
hager

hager TRE500 Motion Detectors

Product Information

  • Product   Name: TRE50., TRE52.
  • Description: IP55 TP RF 230V~ Bus 30V V2.6.0
  • Color Options: EE855 White, EE856 Anthracite
  • Model Numbers: 52125 (White), 52126 (Anthracite)
  • Adjustments: Delay (lighting time), Brightness Sensitivity level, Wall fixing plate, Detection zone, Adjustment potentiometers, Directional detection head, LED A, LED B, Shutters
  • Optimal Installation Height: 2.5m

Product Usage Instructions

  1. Warning: This device should only be installed by a professional electrician fitter according to local applicable installation standards.
  2. Installing Batteries:
  3. Follow the instructions provided in the user manual to install batteries, if applicable.
  4. Product Description and Working Principles:
    • This detector allows remote control of one or more receivers when a movement is detected in its detection zone.
    • The product can be used in two types of configurations:
    • One detector controls one or several receivers.
    • Several transmitters control the receiver(s).
  5. Operation:
    • To perform a factory return:
    1. Keep the J button depressed until LED cfg flashes for more than 10 seconds, and then release it.
    2. The LED cfg will turn off when the factory return is completed.
    3. After the factory return, wait for 15 seconds before starting.
    • Configuration (button J):
    • Set the product in configuration mode by pressing the J button once during the teaching session of TX100 or for addressing with TR131 in ETS.
    • Note: Factory return is required to change the configuration mode.
    • Test and Validation of Detection Zone:
    • Set potentiometer 2 to Test mode.
    • The Test mode is available for 3 minutes and does not take brightness level into account.
    • Each detected movement turns LED A on for 2 seconds and controls the associated receiver.
    • After 3 minutes without detection, the product is set back to auto mode.
    • Limitation of Detection Zone: You can limit the detection zone using the shutters supplied or by inclining the head.
  6. Mounting:
    • Projection or Ceiling Mount:
    1. Fix the wall plate using the supplied screws.
    2. Clip the detector onto the wall plate.
    3. Tighten the screws to close.
    • Angle Mounting:
    1. The wall fixing plate is fitted between the accessory and the detector.
  7. Precautions for Installation:
    • For optimum detection conditions, please follow these recommendations:
    1. Keep the detector protected from solar radiation and bad weather, as it is sensitive to these conditions.
    2. Maintain a 1m distance between the light source and the detector and keep the detector out of the light source.
  8. Action: Adjustments
    • Use Auto (factory) settings to set automatic lighting turn-on for a given time.
    • The settings are predefined: Lux = [value], delay = 3 minutes, sensitivity = max.
    • Turn automatic lighting on for a given time using Installer settings.
  9. Test and Confirm Detection Zone:
    • Move potentiometer 2 to auto test mode.

Description

hager-TRE500-Motion-Detectors-fig-2

Adjustments

Detection zone

hager-TRE500-Motion-Detectors-fig-4

Shutters

Installation

hager-TRE500-Motion-Detectors-fig-6

Angle fixing support

Warning :
This device is to be installed only by a professional electrician fitter according to local applicable installation standards.

Product Description and working principles

This detector allows remote control of one
or more receivers for a given time when a movement is detected in its detection zone. This product can be used in two types of configuration: one detector controls one/seve-ral receiver(s); several transmitters control the receiver(s).

Operation

  • The receiver(s) is(are) under control as soon as the brightness level as set by potentiometer 2 is considered too low and a movement is detected.
  • Upon detection, the time delay is restarted.
  • If LED A flashes quickly during configuration, the position of potentiometer 1 is not compa-tible with the selected function.
  • If LED B flashes quickly or nothing occurs when starting configuration, check that the batteries are correctly installed and replace them if necessary. Product factory reset is recommended before any new configuration.

Factory return

  • Keep push-button J depressed until LED cfg (flashes (>10s), and then release it.
  • LED cfg is turned off when factory return is completed.
  • This operation causes full delete of product configuration in any configuration mode. After factory return, wait 15s before starting.

Installing batteries

Configuration (button J )

These detectors can be configured in 3 different ways :

  • quicklink : tool-free configuration (using product pushbuttons and LEDs), see User’s Instructions 6T7952 supplied with the product.
  • TX100/B V2.5.0 or above : description of product functions available from the Manufacturer.
  • ETS3 or via TR131 : database and description of application software available from the Manufacturer.

Configuration by TX100 or ETS
Set the product in configuration mode by pressing J button once during the teaching session of TX100 or for addressing with TR131 in ETS.
Product factory return is required to change the configuration mode.

Button

Test and validation of detection zone

  • Set potentiometer 2 to Test mode.
  • The Test mode is available for 3 minutes time and does not take brightness level into account.
  • Each detected movement turns LED A on for 2 seconds.
  • The associated receiver is controlled.
  • After 3 minutes without detection, the product is set back to auto mode.
  • Limitation of detection zone :
    You can limit the detection zone using the shutters supplied or by inclining the head.

Mounting

  • Projection or ceiling mount :
    • Fix the wall plate using the supplied screws.
    •  Clip the detector onto the wall plate
    • Tighten the screws to close.
  • For angle mounting, the wall fixing plate is fitted between the accessory and the detector.

Precautions for installation

For optimum detection conditions, please follow these recommendations :

  • Keep the detector protected from solar radiation and bad weather, as it is sensitive to these conditions.
  •  Maintain 1m distance between the light source and the detector and keep the detector out of the light source.

DISPOSAL

Correct Disposal of This product (Waste Electrical & Electronic Equipment).
(Applicable in the European Union and other European countries with separate collection systems).

  • This marking shown on the product or its literature indicates that it hould not be disposed with other household wasted at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
  • Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes of disposal.

Action

hager-TRE500-Motion-Detectors-fig-10

Kit Description TRE700 / 720

  • The detector and the receiver must be preset in order to operate together.
  • These two products are pre-configured to operate together. Only delay, brightness level and detection zones are to be set by user.
    (Please refer to Detector User’s Instructions).

Other devices can be added to the kit.

  • Various configuration options are available
  • When a detector is associated with a receiver, only 2 functions are available, depending on potentiometer’s position :
    • Red/Green LED) or timer (Red flashing LED) according to the case
    • Delete (LED is OFF)
  • The receiver will offer only the function set by the potentiometer

hager-TRE500-Motion-Detectors-fig-11
Note : During configuration of a detector, Step 2 of the Configuration Instructions shall be ignored.

TROUBLESHOOTING

P roble m C auses s olutions
Unwanted lamp switch on. – Permanent heat source is active in the

detection area (trees, bushes shook by wind or presence of dogs, cats in the detection area).

– The detector is located on top a ventilation grill.

| – Limit detector’s range by adjusting its inclination or by fitting shuttering blades to the lens, or by lowering sensitivity using the adjustment knob.

– Move the detector to another location.

The range of the detector is too narrow.| – Detector’s installation height is not suitable (too high or too low).

– Sloppy ground.

| – Modify installation height (2.5m is optimal).

– Adjust detector’s direction.

Moving vehicle or person is not detected.| – Vehicle’s motor is not enough yet (heat radiation is too weak).

– People move forwards in front of detector.

– Detector energy too low.

| – Install the detector in such a way that objects move within the area in transverse direction.

– Replace power cells.

– Place detector in a suitable location with solar cell directed towards the sun.

Technical specifications

  • Electrical specifications

    • Power Supply : – TRE50., TRE52. 3 x 1,5V AAA
  • Operational characteristics

    • Dimensions (L x w x h) : 153 x 91 x 130 mm
    • Luminosity threshold : 5 —> 1000 Lux
    • Fixed time : 30 s —> 15 min
    • Sensitivity : min. 20%, max. 100%
    • Limiting the detection zone : Adjustable shutters supplied
    • Transmission frequency : 868-868.6 MHz
    • Receiver category : 2
    • Maximum emission power : 25mW
    • RF KNX Communication Media RF knx : RF1.R
    • Configuration mode RF KNX : Quicklink, Easy link
    • Controller, ETS via media coupler
    • Range : 100 m on open field
      Fixing accessories : corner support (sold separately) EE855/52125, EE856/52126
  • Environment

    • Operating temperature : -20 °C —> +55 °C
    • Storage temperature : -20 °C —> +60 °C
    • IK : 04
    • Protection class : IP55
    • Resistance to fire : 750°C

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals