EVOHEAT Fusion Series Swimming Pool Heat Pump Unit User Manual
- June 12, 2024
- EVOHEAT
Table of Contents
EVOHEAT Fusion Series Swimming Pool Heat Pump Unit
Product Information
The Swimming Pool Heat Pump Unit is a durable and efficient device designed to heat swimming pool water. It features a heat exchanger made of PVC & Titanium tube, which can withstand prolonged exposure to swimming pool water. The unit can be installed both outdoors and indoors, providing installation flexibility. It operates quietly due to its efficient rotary/ scroll compressor and low-noise fan motor. The unit includes micro-computer controlling, allowing for easy parameter setting and operation status display on the LED wire controller.
Product Usage Instructions
Installation and Connection
Before installation, ensure the following variables are carefully checked to allow the unit to operate correctly:
- For indoor pools, consult the supplier and avoid placing the unit in an enclosed area where the discharge air can be re-circulated.
- In an enclosed area, ensure proper ventilation to evacuate the cold waste air and supply adequate air for the heat pump.
Installation illustration
Installation items:
The factory only provides the main unit and the water unit; the other items in
the illustration are necessary spare parts for the water system ,that provided
by users or the installer.
Attention:
Please follow these steps when using for the first time
- Open valve and charge water.
- Make sure that the pump and the water-in pipe have been filled with water.
- Close the valve and start the unit.
ATTN: It is necessary that the water-in pipe is higher than the pool
surface.
The schematic diagram is for reference only. Please check the water
inlet/outlet label on the heat pump while plumbing installation.
3.2 Swimming Pool Heat Pumps Location
Before installation it is very important to ensure 4 variables are carefully
checked to allow the unit to operate correctly:3.2 Swimming Pool Heat Pumps
Location
Before installation it is very important to ensure 4 variables are carefully
checked to allow the unit to operate correctly:
- Adequate Air Flow
- Correct water flow volume
- Correct electrical connection & supply
- Heater condition
- For indoor pools please consult the supplier.
DO NOT place the unit in an enclosed area, where the units discharge air can be re-circulated. In an enclosed area take measures to evacuate the cold waste air out of the room. Conversely make sure there is adequate air entering the room to supply the heat pump.
Location & minimum clearances
Evo recommend the heat pump should ONLY be installed in a location with
appropriate ventilation. Se above for minimum airflow clearances. The Evo pool
heat pump should be installed with a minimum clearance of at least 3.5m to the
water’s edge. Furthermore, EvoHeat recommend installing the heat pump no
greater than 7.5 meters away from the water’s edge due to heat loss from the
piping. If you do not have a location with these suggested clearances, please
contact our EvoHeat Tech Support Specialist on 1300 859 933 to discuss
appropriate installation locations. The heat pump should be installed a
maximum of 5m below the water level of the pool/spa. Make sure the heat pump
is not located where large amounts of water may run-off from a roof into the
unit. Sharp sloping roofs without gutters will allow excessive amounts of rain
water mixed with debris from the roof to be forced through the unit. A water
deflector may be needed to protect the heat pump. If installing the heater on
an existing pump/filtration system the heater must be installed AFTER the
filter and BEFORE the chlorinator/sanitizer. The heat pump should be installed
on a flat level surface. In the event that a suitable location is unavailable
contact Evo Industries for specialist technical advice.
Swimming Pool Heat Pumps Location
Recommended clearances for installation:
- Air inlet: Minimum clearance of 500mm
- Air outlet: Minimum clearance of 700mm
The Swimming Pool Heat Pumps exclusive rated flow titanium heat exchanger
requires no special plumbing arrangements except bypass(please set the flow
rate according to the nameplate). The water pressure drop is less than 10kPa
at max. Flow rate. Since there is no residual heat or flame Temperatures, The
unit does not need copper heat sink piping. PVC pipe can be run straight into
the unit.
Location: Connect the unit in the pool pump discharge (return) line
downstream of all filter and pool pumps, and upstream of any chlorinators,
ozonators or chemical pumps.
Standard model have slip glue fittings which accept 32mm or 50 mm PVC pipe for
connection to the pool or spa filtration piping. By using a 50 NB to 40NB you
can plumb 40NB Give serious consideration to adding a quick coupler fitting at
the unit inlet and outlet to allow easy draining of unit for winterizing and
to provide easier access should servicing be required.
Condensation: Since the Heat pump cools down the air about 4 -5 , water
may condense on the fins of the horseshoe shaped evaporator. If the relative
humidity is very high, this could be as much as several litres an hour. The
water will run down the fins into the base pan and drain out through the
barbed plastic condensation drain fitting on the side of the base pan. This
fitting is designed to accept 20mm clear vinyl tubing which can be pushed on
by hand and run to a suitable drain. It is easy to mistake the condensation
for a water leak inside the unit.
NB: A quick way to verify that the water is condensation is to shut off
the unit and keep the pool pump running. If the water stops running out of the
basepan, it is condensation.
AN EVEN QUICKER WAY IS to TEST THE DRAIN WATER FOR CHLORINE – if the is no
chlorine present, then it’s condensation.
Swimming Pool Heat Pumps Electrical Wiring
NOTE: Although the unit heat exchanger is electrically isolated from the
rest of the unit, it simply prevents the flow of electricity to or from the
pool water. Grounding the unit is still required to protect you against short
circuits inside the unit. Bonding is also required.
The unit has a separate molded-in junction box with a standard electrical
conduit nipple already in place. Just remove the screws and the front panel,
feed your supply lines in through the conduit nipple and wire-nut the electric
supply wires to the three connections already in the junction box (four
connections if three phase). To complete electrical hookup, connect Heat Pump
by electrical conduit, UF cable or other suitable means as specified (as
permitted by local electrical authorities) to a dedicated AC power supply
branch circuit equipped with the proper circuit breaker, disconnect or time
delay fuse protection. Disconnect – A disconnect means (circuit breaker ,
fused or un-fused switch) should be located within sight of and readily
accessible from the unit, This is common practice on commercial and
residential air conditioners and heat pumps. It prevents remotely-energizing
unattended equipment and permits turning off power at the unit while the unit
is being serviced.
Initial startup of the Unit
NOTE: In order for the unit to heat the pool or spa, the filter pump must
be running to circulate water through the heat exchanger.
Start up Procedure – After installation is completed, you should follow these
steps:
- Turn on your filter pump. Check for water leaks and verify flow to and from the pool.
- Turn on the electrical power supply to the unit, then press the key ON/OFF of wire controller, It should start in several seconds.
- After running a few minutes make sure the air leaving the top(side) of the unit is cooler(Between 5-10 )
- With the unit operating turn the filter pump off. The unit should also turn off automatically,
- Allow the unit and pool pump to run 24 hours per day until desired pool water emperature is reached. When the water-in temperature reach setting, The unit just shuts off. The unit will now automatically restart (as long as your pool pump is running)when the pool temperature drops more than 2 below set temperature.
Time Delay: The unit is equipped with a 3 minute built-in solid state restart delay included to protect control circuit components and to eliminate restart cycling and contactor chatter. This time delay will automatically restart the unit approximately 3 minutes after each control circuit interruption. Even a brief power interruption will activate the solid state 3 minute restart delay and prevent the unit from starting until the 5 minute countdown is completed. Power interruptions during the delay period will have no effect on the 3 minute countdown.
The heat pump should be installed with a minimum clearance of at least 3.5m to the water’s edge. It is also recommended to install the heat pump no greater than 7.5 meters away from the water’s edge to minimize heat loss from the piping. If you have different clearances or need assistance with installation locations, contact EvoHeat Tech Support Specialist at 1300 859 933.
Initial Start-up of the Unit
Follow these steps when using the unit for the first time:
- Open the valve and charge water.
- Ensure the pump and water-in pipe are filled with water.
- Close the valve and start the unit.
Note: The water-in pipe should be higher than the pool surface.
Usage and Operation
The unit is equipped with a controller for easy operation. The function of
the controller includes setting operation parameters and displaying operation
status. Refer to the parameter table and malfunction table in the user manual
for detailed information on various settings and troubleshooting.
Maintenance and Inspection
Refer to the user manual’s maintenance and inspection section for detailed
instructions on how to properly maintain and inspect the Swimming Pool Heat
Pump Unit.
-
Do I need to get my unit serviced regularly?
It is recommended that you get your EvoHeat unit serviced once a year by your local certified air conditioning or refrigeration technician. If your unit is located in a coastal area, more frequent maintenance may be necessary. During the service, they will check the operational pressures of the refrigeration system and give the unit and fins a good clean to ensure maximum performance. -
Do we have recommended service agents?
EvoHeat have a large database of recommended service agents. Please contact EvoHeat tech support on 1300 859 933 for your local service agent details.
Should I check my unit regularly?
We recommend you check your unit regularly to avoid potential issues and
damage to your heat pump.
What should I check?
Check the water inlet/outlets often for leaks. You should avoid the condition
of no water or air entering into the system, as this will influence unit’s
performance and reliability. You should clear the pool/spa filter regularly to
avoid damage to the unit as a result of the dirty of clogged filter. The area
around the unit should be dry, clean and well ventilated. Make sure there is
nothing blocking the airflow of the heater e.g. Leaf litter. Discharge all
water in the water pump and water system, so that freezing of the water in the
pump or water system does not occur. You should discharge the water at the
bottom of water pump if the unit will not be used for an extended period. You
should check the unit thoroughly and fill the system with water fully before
using it for the first time after a period of time. Check the power supply and
cable connection often, should the unit begin to operate abnormally, switch it
off and contact the qualified technician
PREFACE
-
In order to provide our customers with quality, reliability and versatility, this product has been made to strict production standards. This manual includes all the necessary information about installation, debugging, discharging and maintenance. Please read this manual carefully before you open or maintain the unit. The manufacture of this product will not be held responsible if someone is injured or the unit is damaged, as a result of improper installation, debugging, or unnecessary maintenance. It is vital that the instructions within this manual are adhered to at all times. The unit must be installed by qualified personnel.
-
The unit can only be repaired by qualified installer centre , personnel or an authorised dealer.
-
Maintenance and operation must be carried out according to the recommended time and frequency, as stated in this manual.
-
Use genuine standard spare parts only.
Failure to comply with these recommendations will invalidate the warranty. -
Swimming Pool Heat Pump Unit heats the swimming pool water and keeps the temperature constant. For split type unit, The indoor unit can be Discretely hidden or semi-hidden to suit a luxury house.
Our heat pump has following characteristics:
-
Durable
The heat exchanger is made of PVC & Titanium tube which can withstand prolonged exposure to swimming pool water. -
Installation flexibility
The unit can be installed outdoors or indoors. -
Quiet operation
The unit comprises an efficient rotary/ scroll compressor and a low-noise fan motor, which guarantees its quiet operation. -
Advanced controlling
The unit includes micro-computer controlling, allowing all operation parameters to be set. Operation status can be displayed on the LED wire controller. Remote controller can be chosen as future option.
SPECIFICATION
The dimensions for Swimming Pool Heat Pump Unit
Fusion 9/13
Fusion 6
The dimensions for Swimming Pool Heat Pump Unit
Fusion 17
Unit: mm
USAGE
Function of wire controller
Key | Key name | Key function |
---|---|---|
ON/OFF | Press this key to turn on/off the unit. | |
Up | Press this key to select the upward option or increase the parameter |
value.
| Down| Press this key to select the downward option or decrease the parameter
value.
Usage of wire controller
Turn ON/OFF the unit
When the unit is off, press the key and hold on for 0.5s to turn on the unit;
When the unit is on, press the key and hold on for 0.5s to turn off the unit;
Setting temperature
In the running interface press or then the current mode target-temperature
flashes, then press to increase the temp .value, or press to decrease it.
Press will not save setting parameter but back to the main interface
Attention: If there is no operation for 5s system would remember
parameter setting and back to the main interface.
In the main interface press for 2s to see the outlet temp. The parameter
flashes and the display returns to the main interface after 10s.
Running interface
Mode switch
In the main interface ,press and for 0.5s can set the mode, press or to change
the current mode, you can switch different modes of colling, heating and auto
mode. If there is no operation for 5s system will save the current mode and
back to the main interface,press can not save setting The modes switching is
useless of the unit you buy is singel-cold/single-heat unit
Keyboard lock
To avoid mis-operations, please lock the controller after parameter setting.
At the main interface, pressing for 5 seconds,when hearing one sound, the
keyboard is locked. When the keyboard is locked, pressing the keyboard lock is
open.
NOTES: When the unit is in alarming state, the key lock can be removed automaticly.
Malfunction display
There will be malfunction code showing on the controller screen when relative
malfunction occurs. If there are more than one malfuctions occurs at the same
time, you can check the current error codes list by pressing or key. You can
refer to the malfunction table to find out the failure cause and solution.
For example
Parameter table
Meaning | Default | Remarks |
---|---|---|
Set-point of colling mode target temp. | 27 | Ajustable |
Set-point of heating mode target temp. | 27 | Ajustable |
Set-point of auto mode target temp. | 27 | Ajustable |
Malfunction Table
APPENDIX
Connection of PCB illustration
Connections explanation
No. | Symbol | Meaning |
---|---|---|
1 | OUT1 | Compressor of system1 220-230VAC |
2 | OUT2 | Water pump 220-230VAC |
3 | OUT3 | 4way valve 220-230VAC |
4 | OUT4 | High speed of fan motor 220-230VAC |
5 | OUT5 | Low speed of fan motor 220-230VAC |
6 | AC-N | Neutral wire |
7 | NET GND 12V | Wire controller |
8 | DI01 GND | On/Off Switch(input)(no use) |
9 | DI02 GND | Flow switch (input)( normal close) |
10 | DI03 GND | Low pressure protect |
11 | DI04 GND | High pressure protect |
12 | DI05 GND | No use |
13 | DI06 GND | No use |
14 | AI01 GND | Suction temp.(input) |
15 | AI02 GND | Water in temp.(input) |
16 | AI03 GND | Water out temp.(input) |
17 | AI04 GND | Temp. Of coil ( input) |
18 | AI05 GND | Ambient temp.(input) |
19 | AI06 GND | Adjustable fan speed/Exhaust temperature |
20 | CN1 | Primary transformer |
21 | CN2 | Secondary transformer |
22 | CN6 | Without use |
23 | CN19 | Electronic expansion valve |
24 | 5V CN16 GND | Flow meter |
Caution & Warning
-
The unit can only be repaired by qualified installer centre personnel or an authorised dealer. for Europe market
-
This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. for Europe market
Children should be supervised to ensure that they do not play with the appliance. -
Please make sure that the unit and power connection have good earthing, otherwise may cause electrical shock.
-
If the supply cord is damaged, it must be replaced by the manufacturer or our service agent or similarly qualified person in order to avoid a hazard.
-
Directive 2002/96/EC (WEEE):
The symbol depicting a crossed-out waste bin that is underneath the appliance indicates that this product, at the end of its useful life, must be handled separately from domestic waste, must be taken to a recycling centre for electric and electronic devices or handed back to the dealer when purchasing an equivalent appliance. -
Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC (RoHs) concerning restrictions for the use of harmful substances in electric and electronic devices.
-
The unit CANNOT be installed near the flammable gas. Once there is any leakage of the gas , fire can be occur.
-
Make sure that there is circuit breaker for the unit, lack of circuit breaker can lead to electrical shock or fire.
-
The heat pump located inside the unit is equipped with an over-load protection system. It does not allow for the unit to start for at least 3 minutes from a previous stoppage.
-
The unit can only be repaired by the qualified personnel of an installer center or an authorized dealer. for North America market
-
Installation must be performed in accordance with the NEC/CEC by authorized person only. for North America market
-
USE SUPPLY WIRES SUITABLE FOR 75 .
-
Caution: Single wall heat exchanger, not suitable for potable water connection.
Cable specification
- Single phase unit
Nameplate maximum current| Phase line| Earth line| MCB| Creepage protector| Signal line
---|---|---|---|---|---
No more than 10A| 2 1.5mm2| 1.5mm2| 20A| 30mA less than 0.1 sec| n 0.5mm2
10~16A| 2 2.5mm2| 2.5mm2| 32A| 30mA less than 0.1 sec
16~25A| 2 4mm2| 4mm2| 40A| 30mA less than 0.1 sec
25~32A| 2 6mm2| 6mm2| 40A| 30mA less than 0.1 sec
32~40A| 2 10mm2| 10mm2| 63A| 30mA less than 0.1 sec
40 ~63A| 2 16mm2| 16mm2| 80A| 30mA less than 0.1 sec
63~75A| 2 25mm2| 25mm2| 100A| 30mA less than 0.1 sec
75~101A| 2 25mm2| 25mm2| 125A| 30mA less than 0.1 sec
101~123A| 2 35mm2| 35mm2| 160A| 30mA less than 0.1 sec
123~148A| 2 50mm2| 50mm2| 225A| 30mA less than 0.1 sec
148~186A| 2 70mm2| 70mm2| 250A| 30mA less than 0.1 sec
186~224A| 2 95mm2| 95mm2| 280A| 30mA less than 0.1 sec - Three phase unit
Nameplate maximum current| Phase line| Earth line| MCB| Creepage protector|
Signal line
---|---|---|---|---|---
No more than 10A| 3 1.5mm2| 1.5mm2| 20A| 30mA less than 0.1 sec| n 0.5mm2
10~16A| 3 2.5mm2| 2.5mm2| 32A| 30mA less than 0.1 sec
16~25A| 3 4mm2| 4mm2| 40A| 30mA less than 0.1 sec
25~32A| 3 6mm2| 6mm2| 40A| 30mA less than 0.1 sec
32~40A| 3 10mm2| 10mm2| 63A| 30mA less than 0.1 sec
40 ~63A| 3 16mm2| 16mm2| 80A| 30mA less than 0.1 sec
63~75A| 3 25mm2| 25mm2| 100A| 30mA less than 0.1 sec
75~101A| 3 25mm2| 25mm2| 125A| 30mA less than 0.1 sec
101~123A| 3 35mm2| 35mm2| 160A| 30mA less than 0.1 sec
123~148A| 3 50mm2| 50mm2| 225A| 30mA less than 0.1 sec
148~186A| 3 70mm2| 70mm2| 250A| 30mA less than 0.1 sec
186~224A| 3 95mm2| 95mm2| 280A| 30mA less than 0.1 sec
When the unit will be installed at outdoor, please use the cable which can against UV.
Warranty
Please refer to the EvoHeat website for warranty details
- Australia: www.evoheat.com.au
- South East Asia: www.evoheat.com.sg
- Warranty terms are from date of purchase.
- This warranty excludes any defect or injury caused by or resulting from misuse, abuse, neglect, accidental damage, improper voltage, vermin infestation, incompetent installation, any fault not attributable to faulty manufacture or parts, any modifications which affect the reliability or performance of the unit.
- This warranty does not cover the following:
- Natural Disasters (hail, lightening, flood, fire etc.)
- Rust or damage to paintwork caused by a corrosive atmosphere
- When serviced by an unauthorized person without the permission of Evo Industries
- When a unit is installed by an unqualified person
- Where a unit is incorrectly installed
- When failure occurs due to improper or faulty installation
- Failure due to improper maintenance (refer Operating Instructions)
- ‘No Fault Found’ service calls where the perceived problem is explained within the
- Costs associated with delivery, handling, freighting, or damage to the product in transit.
- If warranty service is required you should: a. contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b. provide a copy of your receipt as proof of purchase c. have completed the online warranty registration or provide a completed warranty card.
- Onsite technical service is available within the normal operating area of your Evo Industries authorized Service Centre. Service outside this area will incur a traveling fee.
- Unless otherwise specified to the purchaser, the benefits conferred by this express warranty and additional to all other conditions, warranties, rights and remedies expressed or implied by the Trade Practices Act 1974 and similar consumer protection provisions contained in legislation of the States and Territories and all other obligations and liabilities on the part of the manufacturer or supplier and nothing contained herein shall restrict or modify such rights, remedies, obligations or liabilities.
Warranty Registration
To register your Warranty, please enter the following details or go online at https://evoheat.com.au/warranty-registration/ to register directly at our website. Fields with a star (*) must be filled in. For information about what Evo Industries Australia will do with your personal details, please refer to our Privacy Disclaimer on our website.
- Family Name: * ___
- Given Name: * ___
- Preferred Title: *___
- Age Group: * 18-24 25-34 35-44 45-54 55-64 64+
- Street Address: * ___
- Suburb: * ____
- Postcode: * ___
- State: * _____
- Email: * _____
Please tell us about which EvoHeat product you bought, who you bought it from and what you will be using it for.
- Product & Model: *_____
- Serial Number:* ____
- Authorised Installer:* ___
- Date Purchased: *__
- Date Installed:* ____
- Receipt Number: *_____
- Company you bought it from: *___
- Did you purchase the item when you purchased your pool?: ____
- If you purchased it after the pool, how many years did you wait?: ____
- What size is your pool or spa?: ____
- Why did you choose an EVOHEAT product? ____