ACDC DYNAMICS 6FM24 12Volt 24Ah General Series Battery Owner’s Manual
- June 12, 2024
- ACDC DYNAMICS
Table of Contents
ACDC DYNAMICS 6FM24 12Volt 24Ah General Series Battery Owner’s Manual
General Series VRLA batteries are designed with AGM(Absorbent extra power output for common power backup system. General SeriesBatteries are the general purpose batteries with 5 years floating design life at 25˚C. Glass Mat) technology,High performance plates and electrolyte togive
Application
- Emergency Power System
- Communication equipment
- Telecommunication systems
- Uninterruptible power supplies
- Electric toy car and wheelchairs, etc
- Power tools
- Alarm system
- Marine equipment
- Medical equipment
- Fire and Security System
General Features
- Heavy Duty Grid
- Mechanized assembly
- Non-spillable construction
- High Reliability and Stability
- Sealed and Maintenance-free
- Long Life and low self-discharge design
Construction
- Positive……..Lead dioxide
- Electrolyte……..Sulfuric acid
- Separator……..Fiber glass
- Container……..ABS(UL94-HB) / Flame Retardant ABS (UL94-V0)
- Negative……..Lead
- Safety Valve……..EPDR
- Terminal……..Copper
Specification
Battery Model | Nominal Voltage | 12V |
---|---|---|
Rated capacity (20Hour rate) | 24Ah | |
Cells Per battery | 6 | |
Dimension | Length | Width |
166mm | 175mm | 125mm |
Approx Weight | 6.8Kg | |
Internal Resistance | ||
Max.discharge current | 360A(5s) | |
Floating design life @ 25 (77 ) | 5 years | |
Capacity @ 25 (77 ) | 20Hour rate(1.2A/10.5V) | 10Hour rate(2.16A/10.8V) |
5Hour rate(3.46A/10.8V) | 1Hour rate(9.24A/10.5V) | |
24Ah | 21.6Ah | 17.34Ah |
Capacity affected by Temp(20 HR) | 40 | (104 |
(5 | ) | |
102% | 100% | 85% |
Self Discharge @ 25 (77 ) | After 3 months storage | After 6 months storage |
After 12 months storage
91%| 82%| 64%
Charge method @ 25 (77 )| Cycle Use| 14.5-14.9V (Initial charging current
less than 7.2 A)
Float Use| 13.6-13.8V
Outer Dimension(mm)
Terminal Type(mm)
Constant Current(Amp) and Constant Power(Watt) Discharge Table at 25˚C
(77˚F)
F.V / TIME | 5min | 10min | 15min | 30min | 1h | 2h | 3h | 4h | 5h | 8h | 10h | 20h |
---|
9.60V
| A| 86.40| 56.40| 42.00| 27.60| 14.40| 8.40| 6.24| 4.96| 4.21| 2.78| 2.28|
1.22
W| 915.84| 598.97| 449.40| 298.08| 156.96| 91.56| 68.64| 54.56| 46.31| 30.86|
25.31| 13.77
10.20V
| A| 79.20| 53.00| 38.60| 26.20| 14.88| 8.06| 6.12| 4.80| 4.13| 2.74| 2.23|
1.21
W| 863.28| 588.30| 430.39| 294.75| 167.40| 91.08| 69.16| 54.48| 46.88| 31.05|
25.31| 13.74
10.50V
| A| 73.45| 50.64| 36.00| 25.40| 14.40| 7.90| 6.00| 4.56| 4.08| 2.70| 2.21|
1.20
W| 807.95| 569.70| 406.80| 289.56| 164.16| 90.46| 68.70| 52.44| 46.92| 31.05|
25.39| 13.80
10.80V
| A| 66.88| 48.40| 33.60| 24.24| 13.92| 7.70| 5.88| 4.48| 3.90| 2.63| 2.15|
1.17
W| 735.68| 551.76| 384.72| 279.97| 160.78| 88.93| 68.21| 52.19| 45.44| 30.64|
25.05| 13.63
11.10V
| A| 57.84| 45.60| 31.20| 22.56| 13.20| 7.50| 5.64| 4.40| 3.73| 2.56| 2.10|
1.14
W| 653.59| 526.68| 361.92| 263.95| 154.44| 87.75| 66.27| 51.92| 44.01| 30.21|
24.78| 13.45
National Sales Centre – 010 202 3400 | Technical – 010 202 3500
T H I N K E L E C TRICA L
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>