6FM12 12Volt 12Ah General Series Battery

General Series VRLA batteries are designed with AGM(Absorbent extra power output for common power backup system. General SeriesBatteries are the general purpose batteries with 5 years floating design life at 25˚C. Glass Mat) technology,High performance plates and electrolyte togive

Application

• Emergency Power System
• Communication equipment
• Telecommunication systems
• Uninterruptible power supplies
• Electric toy car and wheelchairs, etc| • Power tools
• Alarm system
• Marine equipment
• Medical equipment
• Fire and Security System
---|---

General Features

  • Heavy Duty Grid
  • Mechanized assembly
  • Non-spillable construction
  • High Reliability and Stability
  • Sealed and Maintenance-free
  • Long Life and low self-discharge design

Construction

  • Positive……..Lead dioxide
  • Electrolyte……..Sulfuric acid
  • Separator……..Fiber glass
  • Container……..ABS(UL94-HB) / Flame Retardant ABS (UL94-V0)
  • Negative……..Lead
  • Safety Valve……..EPDR
  • Terminal……..Copper

Specification

Battery Model Nominal Voltage 12V
Rated capacity (20Hour rate) 12Ah
Cells Per battery 6
Dimension Length Width
151mm 98mm 94mm
Approx Weight 3.30Kg
Internal Resistance Full charged at 25°C (77°F ): Approx 17mG
Max.discharge current 180A(5s)
Floating design life @ 25°C (77°F ) 5 years
Capacity @ 25°C (77°F) 20Hour rate(0.6A/10.5V) 10Hour rate(1.08A/10.8V)
5Hour rate(1.73A/10.8V) 1 Hour rate(4.62A/10.5V)
12Ah 10.8Ah 8.67Ah
Capacity affected by Temp(20 HR) 40°C (104°F) 25°C (77°F)

-15°C(5°F)
102%| 100%| 85%| 65%
Self Discharge @ 25°C (77°F)| After 3 months storage| After 6 months storage| After 12 months storage
91%| 82%| 64%
Charge method @ 25°C (77°F)| Cycle Use| 14.5-14.9V (Initial charging current less than 3.6 A)
Float Use| 13.6-13.8V

Outer Dimension(mm) Terminal Type(mm) Constant Current(Amp) and Constant Power(Watt) Discharge Table at 25˚C (77˚F)

F.V / TIME 5min 10min 15min 30min 1h 2h 3h 4h 5h 8h 10h 20h
9.60V A 43.20 28.20 21.00 13.80 7.20 4.20 3.12 2.48 2.11 1.39
1.14 0.61
W 457.92 299.48 224.70 149.04 78.48 45.78 34.32 27.28 23.16 15.43
12.65 6.89
10.20V A 39.60 26.50 19.30 13.10 7.44 4.03 3.06 2.40 2.06 1.37
1.12 0.61
W 431.64 294.15 215.19 147.38 83.70 45.54 34.58 27.24 23.44 15.53
12.66 6.87
10.50V A 36.73 25.32 18.00 12.70 7.20 3.95 3.00 2.28 2.04 1.35
1.10 0.60
W 403.98 284.85 203.40 144.78 82.08 45.23 34.35 26.22 23.46 15.53
12.70 6.90
10.80V A 33.44 24.20 16.80 12.12 6.96 3.85 2.94 2.24 1.95 1.31
1.07 0.59
W 367.84 275.88 192.36 139.99 80.39 44.47 34.10 26.10 22.72 15.32
12.52 6.82
11.10V A 28.92 22.80 15.60 11.28 6.60 3.75 2.82 2.20 1.87 1.28
1.05 0.57
W 326.80 263.34 180.96 131.98 77.22 43.88 33.14 25.96 22.01 15.10
12.39 6.73

General Series Battery

6FM12/12Volt 12Ah
Discharge characterstic Curve Cycle service life in relation to depth of discharge Relationship between charging voltage and temperature Constant voltage charging characteristic (0.25CA, at 25˚C) Temperature effects on float life Self-discharge characteristic Life characteristics of standby use Charge characterstic for standby use

National Sales Centre – 010 202 3400
Technical – 010 202 3500
www.acdc.co.za
THINK ELECTRICAL

Documents / Resources

| ACDC DYNAMICS 6FM12 12Volt 12Ah General Series Battery [pdf] Owner's Manual
SY12012, 6FM12, 6FM12 12Volt 12Ah General Series Battery, 12Volt 12Ah General Series Battery, 12Ah General Series Battery, General Series Battery, Battery
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals