sygonix 2735095 Wireless Heating Thermostat Instruction Manual
- June 12, 2024
- Sygonix
Table of Contents
- Intended use
- Delivery content
- Up-to-date operating instructions
- Description of symbols
- Safety instructions
- Components and controls
- Operation and use
- System settings and defaults
- Error codes
- Range
- Care and cleaning
- Declaration of Conformity (DOC)
- Disposal
- Technical data
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Operating instructions
Wireless heating thermostat
Item no. 2735095
Intended use
This product is a wireless heating thermostat intended for temperature control
and can be integrated into an electric heating system, such as floor heating
or panel radiators.
You can schedule the room temperature precisely to the hour to suit your
individual needs.
You can programme the room temperature for 7 days in advance. With six
programmable time settings a day, you can reduce your heating costs and adjust
the temperature in your home to your needs. You can save on heating costs when
you are on holiday or away on business. The holiday mode keeps the temperature
in your home constant at a preset level.
The wireless heating thermostat is powered by two Mignon batteries (AA). The
switching receiver is connected directly to the mains voltage. You can also
connect a consumer operated via the mains voltage supply to the switching
receiver and switch it on or off through temperature control.
The heating thermostat has a built-in temperature sensor (probe) and allows
connecting an external sensor to the switching module. The product has a
button lock feature that prevents incorrect operation and a permanently
installed decoupling capacitor for data backup in the event of a power
failure. This device has an IP20 ingress protection rating and is suitable for
dry rooms and indoor use. Do not use it outdoors. Contact with moisture, e.g.
in bathrooms, must be avoided under all circumstances.
For safety and approval purposes, do not rebuild and/or modify this product.
If you use the product for purposes other than those described above, the
product may be damaged. In addition, improper use can result in short
circuits, fires, electric shocks or other hazards. Read the instructions
carefully and store them in a safe place. Make this product available to third
parties only together with its operating instructions.
This product complies with the statutory national and European requirements.
All company and product names contained herein are trademarks of their
respective owners. All rights reserved.
Delivery content
- Radio room thermostat
- Switching module
- 4x Screw
- Operating instructions
Up-to-date operating instructions
Download the latest operating instructions at www.conrad.com/downloads or scan the QR code shown. Follow the instructions on the website.
Description of symbols
This symbol warns of dangerous voltage that can lead to injury from electric
shock.
Read the information carefully.
**** The symbol with the exclamation mark in the triangle indicates important
information in this document. Always read this information carefully.
The product should only be used in dry, indoor locations. It must not get damp
or wet.
The product is designed according to protection Class II (reinforced or double
insulation, protective insulation).
Pay attention to the operating instructions!
Safety instructions
****Read the operating instructions carefully and adhere in particular to the safety instructions. If you do not heed the safety instructions and information on proper handling in these operating instructions, we will assume no liability for any resulting personal injury or property damage. Such cases will also invalidate the warranty/guarantee.
5.1 General information
-
This product is not a toy. Keep it out of the reach of children and pets.
-
Do not leave packaging material lying around carelessly, as it could become a dangerous plaything for children.
-
Protect the product from extreme temperatures, direct sunlight, strong jolts, high humidity, moisture, flammable gases, vapours and solvents.
-
Do not expose the product to any mechanical stress.
-
If it is no longer possible to operate the product safely, take it out of operation and protect it from any accidental use. Safe operation can no longer be guaranteed if the product:
– is visibly damaged,
– is no longer working properly,
– has been stored for extended periods in poor ambient conditions or
– has been subjected to any serious transport-related stress. -
Please handle the product carefully. Jolts, impacts or a fall even from a low height can damage the product.
-
Consult a technician when in doubt about the operation, safety or connection of the appliance.
-
If you have questions which remain unanswered by these operating instructions, contact our technical support service or other technical personnel.
5.2 Installation/connection
Caution, safety hazard!
The product should only be installed and connected by people with relevant
electrical knowledge and experience! *)
If the product is not installed properly, you risk:
- your own life;
- the life of the person using the electrical device.
If the product is not installed properly, you risk severe damage to property,
e.g. due to fire. You face the risk of personal liability for personal injury
and material damage.
Always consult an electrician!
*) Technical knowledge required to perform the installation!
The following specialist knowledge is required for installation:
- The “Five Safety Rules”: Disconnect from the mains; protect against accidental switch-on; ensure there is no voltage; earth and short-circuit; cover or protect adjacent live parts.
- Use of suitable tools, measuring devices and personal protective equipment, where necessary.
- Analysis of measurement results.
- Use of electrical installation materials to meet the requirements for safe disconnection from the power supply.
- IP protection ratings.
- Installation of electrical installation materials.
- Type of power supply (TN system, IT system, TT system) and the corresponding connection criteria (classic earthing, protective earthing, necessary additional measures, etc.)
If you do not have sufficient knowledge in all of the aforementioned topics, contact a specialist and do not attempt to install or connect the product yourself.
Further warnings:
- The construction of the product corresponds to the protection-class II (double or reinforced isolation). Ensure that the insulation of the housing is neither damaged nor destroyed.
- Before installing the switching module, disconnect all poles from the mains voltage using a residual current device (RCD). There must be an appropriately rated fuse or circuit breaker between the RCD and the product.
- The device must be deenergized during installation and connection of the switching module. Furthermore, turn off the automatic circuit breaker and the RCD to disconnect all poles from the mains voltage. Secure it against unauthorized reconnection, e.g. with a warning sign. Then check to ensure there is no voltage with a suitable measuring device (e.g. a two-pole voltage tester).
- Never connect the product to the power supply immediately after it has been transferred from a cold room into a warm one (e.g., during transport). The condensation that forms may destroy the device. Moreover, there is danger of electric shock!
- Always let the product reach room temperature first. Wait until the condensation has evaporated. In some cases, this may take several hours. Only once the condensation has evaporated should it be installed, connected to the power supply and put into use.
- Do not use the product in rooms with adverse environmental conditions, where combustible gases, vapours or dust are or may be present! This may cause an explosion!
5.3 Protection class
- This device has an IP20 ingress protection rating and is suitable for dry rooms.
- There is protection against touching live components and ingress from foreign particles >12.5 mm.
- There is no protection against water, combustible gases, and vapours.
Components and controls
6.1 Wireless thermostat 6.2 Switching module
ON/OFF | Switches the switching module on or off. |
---|---|
POWER | Power light (green) goes on when the device is switched on. |
Load | Load/fault light (red) |
Normal status: Lights up when the consumer is switched on. Error:
– When the light flashes 2 times, it means that the IP is faulty.
– When the light flashes 3 times, it means that the device has received no
radio signal for an hour.
– When the light flashes 4 times, it means that the sensor is faulty (only for
receivers with external sensors).
Signal| – Lights up within 10 seconds after power-on. Flashes when a switching
signal is received.
6.3 Display
-
6 programmable periods (morning, work, lunch, afternoon, evening, night)
-
Current time
-
Wireless connection to the switching module
-
Weekday intervals
-
Automatic mode (preset programme is running)
• Press the Settings button briefly to switch between manual and automatic modes. -
Manual mode (manual temperature control)
-
Holiday mode
-
Heating
-
Button lock enabled: Press and hold the button for approx. 3 seconds to unlock.
-
Room temperature (actual temperature)
-
Temperature setting (set temperature)
-
Weekday (1 = Monday, 7 = Sunday)
6.4 Icons
Icon | Meaning |
---|---|
**** | Visible when the keypad is locked. Disappears when keypad is unlocked. |
**** | Visible when heating is ON. Disappears when heating is OFF. |
**** | AUTO mode: Weekly schedule program is running. |
**** | Manual mode. |
**** | Holiday mode: Set the number of days you will be away and a |
temperature.
****| Flashes when there is no wireless connection to the switching module.
When connected, the symbol is displayed permanently.
6.5 Wireless thermostat button functions (a)
Button | Function |
---|---|
**** | Press to turn the power ON/OFF. |
**** | Press this button briefly to toggle between manual and automatic |
modes. Programmable setting: Switch on the device and use this button to
enable the automatic mode . Then press and hold the button for three to five
seconds.
Advanced options setting: Turn power off, then press and hold 3 – 5 sec.
OK| Confirms a setting.
During normal operation press to set the time and day of week.
During normal operation, press and hold 3 – 5 sec to enter “holiday mode”
settings.
With the power off, press and hold for approx. 3 – 5 secs to enter advanced
settings.
▲| Press to increase a value.
Press to temporarily override “auto” mode and increase the temperature (auto
settings will be retained when exiting manual override).
▼| Press to decrease value.
Press and hold to activate/deactivate the keypad lock.
Press to temporarily override “auto” mode and decrease the temperature (auto
settings will be retained when exiting manual override).
Installation
-
To remove the front panel of the thermostat or the switching module, press in the upper clips with a small flat screwdriver and pull off the front panel to the front.
-
There are 6 connecting terminals on the back of the switching module:1, 2) electrical load (consumer)
3, 4) main power supply
5, 6) external NTC thermistor (optional).
• Connect the mains power supply to the corresponding inputs 3 and 4.
• Connect the consumer (e.g. an electric radiator or electric floor heating) to the corresponding outputs 1 and 2.
If the consumer requires a protective earth connection, it must be connected separately. -
You can connect an external temperature sensor (probe) to terminals 5 and 6. There is no polarity so it does not matter which way you connect the wires.
When routing the connection cables, ensure they are protected from sharp edges.
Never fasten the connection cable with nails, screws or similar. -
The mounting height of the thermostat should be approx. 1.5 m above the floor level.
Be careful not to damage the cables during installation. -
Replace the front panels and press them firmly into place. They should click audibly into place.
-
Turn on the mains voltage for the switching module.
-
The thermostat is now ready to use.
Operation and use
7.1 Power ON/OFF
- Pressing the button turns the wireless heating thermostat on and off.
- When the thermostat is switched off, the display goes out and no temperature control takes place.
7.2 Set time and weekday
Notice
You must first switch on the wireless heating thermostat and ensure it is in
normal status (exit the “System settings”). Settings will exit and be saved if
no keys are pressed for approx. 10 seconds.
-
Press OK and the minutes will flash.
– Press ▲ or ▼ to adjust values.
– Press ▲ or ▼ to save the setting. -
Adjust the hours:
– Press ▲ or ▼ to adjust values.
– Press OK to save the setting. -
Adjust the day of week (1 = Monday… 7 = Sunday).
– Press ▲ or ▼ to adjust values.
– Press OK to save the setting. -
The settings are saved and the thermostat returns to normal operation.
7.3 Switch between automatic and manual mode
Before doing so, ensure the wall thermostat is on and in normal status (exit
“System settings”).
Pressing the **** button switches between automatic ( ) and manual ( ) modes.
- sensor mode: The temperature settings are based the active program preset.
- Manual: Use the buttons ▲ and ▼ to set the temperature manually.
7.4 Button lock
- Press and hold ▼ for approx. 5 seconds to turn the parental control lock ON / OFF.
- The lock symbol will show to indicate that the parental lock is ON.
You can choose between two different parental locks depending on the settings
under “System settings” –> “General” –> “A3”:
0 = All buttons except the power button will be locked.
1 = All buttons are locked.
7.5 Holiday mode
Before doing so, ensure the wall thermostat is on and in normal status (exit
“System settings”). Use holiday mode to set a time and temperature for the
days you will be away.
Activate
-
Press and hold the
button for three to five seconds to enter the settings menu. -
Turn holiday mode „on“.
– Adjust the value using the buttons ▲ and ▼ (ON = holiday mode enabled).
– Press OK to save the setting. -
Set the number of days you will be away between “1 and 30”.
– Adjust the value using the buttons ▲ and ▼.
– Press OK to save the setting. -
Set the temperature.
– Press ▲ and ▼ or to adjust values.
– Press OK to save the setting. -
The symbol shows on the display to indicate that holiday mode is active.
Exit holiday mode
Press to exit holiday mode and return to manual or auto mode.
7.6 Programming the weekly schedule
Overview: 6 time periods
You can configure temperature settings for 6 time periods throughout the day.
A symbol indicates which time period is active.
Default times and temperatures for each period are shown below:
| | | | |
---|---|---|---|---|---
1: Wake up| 2: Outdoor| 3: Back home| 4: Outdoor| 5:Back home| 6: Sleep
6:00| 8:00| 11:00| 13:30| 17:00| 22:00
21 °C| 17 °C| 21 °C| 17 °C| 21 °C| 17 °C
Weekday interval
Weekday intervals are based on the selected programme. Select “System
settings” –> “General” –> “A5”.
Program | Icon | Weekday interval |
---|---|---|
P1 | 5 days same / 2 days same | |
P2 | 6 days same / 1 day same | |
P3 | 7 days same |
Program a weekly schedule
General setting
- Press the button to turn off the thermostat.
- Press and hold the button for three to five seconds to enter the settings mode.
- Press the button repeatedly to access the setting “A5”.
- Use the buttons ▲ and ▼ to select the desired programme (P1, P2 or P3).
- Press the button again to exit the settings menu. Settings will also be saved if no buttons are pressed for approx. 10 seconds. The menu is exited automatically after 10 seconds.
Programming a schedule
-
Press the button to switch on the thermostat.
-
If the backlight is off, press the button to turn it on, and then press and hold the button for about three to five seconds to enter the settings mode.
The display shows the symbol of the first period “1: Wake up” and the time indication starts flashing. -
Set the time (hours: minutes)
– Press ▲ or ▼ to adjust values.
– Press to save and set the next value. -
Set the temperature
– Press ▲ or ▼ to adjust values.
– Press to save and set the next period
The display shows the symbol of the next period “2: Away” and the time indication starts flashing. -
Repeat steps 3 and 4 to set all 6 periods for the day.
-
Settings will be saved if no buttons are pressed for approx. 10 sec.
Switch programmed schedule ON/OFF
- Press to switch the programmed schedule ON or OFF.
- The icon appears when the programmed schedule is ON.
System settings and defaults
Adjusting system settings may cause your thermostat to behave unexpectedly. Read all instructions carefully before adjusting any settings. Refer to section „Troubleshooting“ for further information.
8.1 General information
-
Press the button to switch off the thermostat.
-
Then, press and hold the button for three to five seconds to enter the general settings mode.
– After that, press the button repeatedly to select the desired setting from “A1” to “Ao”.
– Use the buttons ▲ and ▼ to adjust the values. -
Press the button again to exit the settings menu. Settings will also be saved if no buttons are pressed for approx. 10 seconds.
Display code | Setting | System Settings | Factory default |
---|
A1
| Calibration temperature deviation| Adjustment range -9 to +9 °C| -1 °C
A2| Switching differential (hysteresis)| Adjustment range 0.5 to 5 °C
Example:
If the thermostat measures a temperature of +20 °C with a setting of 1 °C, the
thermostat will switch on the heating at +19 °C and again off at +21 °C.| +1
°C
A3
|
Button lock
| 0 = All buttons except the power button will be locked
1 = All buttons are locked|
0
A4
| Behavior after power failure| 0 = Return to the previous function
1 = Switch off
2 = Switch on|
0
A5| Weekly interval setting| The weekday must be set correctly for the
programme to recognize the weekend. You will find more information under
“Operation and use” –> “Set time and weekday”.
Settings:
P1 = 5 days / 2 days,
P2 = 6 days / 1 day,
P3 = 7 days| 0 = 5 days (Mo-Fr) / 2 days (Sa/Su)
A6| Minimum temperature| Set the lowest selectable temperature.
Adjustment range: +1 to +10 °C| +5 °C
A7| Maximum temperature| Set the highest selectable temperature.
Adjustment range: +20 to +70 °C| 35 °C
A8| Frost protection| The heater will turn on automatically if the sensor
measures the temperature below the preset value.
Settings range: +1 to +10 °C Advanced setting: N1 or N3 (internal sensor)| +5
°C
A9| High temperature protection
(external sensor only)| This feature prevents the floor temperature from
increasing excessively. For example, if the room cannot be heated up to the
preset temperature due to the window being open, the floor heating alone can
try to compensate for the difference.
Advanced setting: N3 only Settings range: +20 to +70 °C Cancel Setting:
Press and hold the ▼ button until the display shows “–”.
Example:
If the sensor measures a temperature of +50 °C with a temperature preset of
+50 °C, the thermostat will switch off the radiator.| 45 °C
AA| High temperature protection/ differential set- ting (external sensor)|
Adjustment range: 1 to 9 °C
Example:
The limit value “AA” is set to +45 °C and “AB” to 2 °C. When a temperature of
+45 °C is reached, the thermostat switches off the heating. When the
temperature drops to +43 °C, the thermostat switches on the heating again. But
this only works if the indoor temperature is lower than the preset
temperature.| +2 °C
Ao| Restore factory defaults| Press and hold the OK button for three to
five seconds until all display items appear at a time.
After the thermostat has been successfully reset to factory defaults, it
switches off.|
8.2 Advanced settings
-
Press the button to switch off the thermostat.
-
Then, press and hold the OK button for three to five seconds to enter advanced settings mode.
– After that, press the button repeatedly to select the desired setting.
– Use the buttons ▲ and ▼ to adjust the values. -
Press the button again to exit the settings menu. Settings will also be saved if no buttons are pressed for approx. 10 seconds.
Display code | Setting | System Settings | Factory default |
---|---|---|---|
PH | IP address “high” | 00 to FF | 00 |
PL | IP address “low” | 01 to FF | 01 |
BS | Programme the IP address of the switching module | Press and hold the ▲ |
button on the thermo- stat.
Switch on the switching module (the orange LED is permanently lit).
After successful transmission of the IP, the thermostat display shows “55”. If
the transmission has failed, repeat the process.| 00
BN| Sensor selection| N1: Internal sensor controls the temperature.
N3. Internal sensor controls the temperature. If N3 is activated, the external
sensor is used as the temperature limiting sensor.| N1
Bo| Product information| Cannot be changed|
Error codes
An error code will show if there is a problem with the internal or external sensor. When this happens the thermostat will stop heating until the cause of the error is removed.
Code | Explanation | Suggestions |
---|---|---|
E1 | Internal sensor error | Switch the thermostat off and contact technical |
support service or other technical personnel.
E2
| External sensor error| Check the external sensor connection.
Switch the thermostat off and contact technical support service or other
technical personnel.
Range
The transmission range of the radio signals between the temperature controller
and a suitable radio receiver is up to 200 m under optimal conditions.
However, this indication refers to the so-called “open field range” (with
direct visual contact between transmitter and receiver without interference).
Different objects have a different impact on the range; therefore, no specific
range can be guaranteed. The range should be sufficient for use in a detached
house.
Sometimes the range can be considerably reduced due to:
- Walls, reinforced concrete ceilings and metal-framed drywalls.
- Coated/metallized insulated glass.
- Proximity to metal and conductive objects (e.g. radiators).
- Proximity to the human body.
- Other devices using the same frequency for communication (e.g. wireless headphones, wireless speakers).
- Proximity to electric motors/appliances, transformers, power supplies, and computers.
Care and cleaning
- This product does not require maintenance.
- Use a dry, soft, lint-free cloth to wipe the panel. Do not use aggressive cleaning agents, as these can cause discolouration.
Always activate the button lock before wiping the front panel. Accidentally pressing the buttons can cause unintended settings.
Declaration of Conformity (DOC)
Conrad Electronic SE, Klaus-Conrad-Straße 1, D-92240 Hirschau hereby declares that this product conforms to the 2014/53/EU directive.
- Click on the following link to read the full text of the EU declaration of conformity: www.conrad.com/downloads
Enter the product item number in the search box. You can then download the EU declaration of conformity in the available languages.
Disposal
13.1 Product
**** This symbol must appear on any electrical and electronic equipment
placed on the EU market. This symbol indicates that this device should not be
disposed of as unsorted municipal waste at the end of its service life.
Owners of WEEE (Waste from Electrical and Electronic Equipment) shall dispose
of it separately from unsorted municipal waste. Spent batteries and
accumulators, which are not enclosed by the WEEE, as well as lamps that can be
removed from the WEEE in a non-destructive manner, must be removed by end
users from the WEEE in a non-destructive manner before it is handed over to a
collection point.
Distributors of electrical and electronic equipment are legally obliged to
provide free take-back of waste. Conrad provides the following return options
free of charge (more details on our website):
- in our Conrad offices
- at the Conrad collection points
- at the collection points of public waste management authorities or the collection points set up by manufacturers or distributors within the meaning of the ElektroG
End users are responsible for deleting personal data from the WEEE to be
disposed of.
It should be noted that different obligations about the return or recycling of
WEEE may apply in countries outside of Germany.
13.2 Batteries/rechargeable batteries
Remove batteries/rechargeable batteries, if any, and dispose of them
separately from the product. According to the Battery Directive, end users are
legally obliged to return all spent batteries/rechargeable batteries; they
must not be disposed of in the normal household waste.
**** Batteries/rechargeable batteries containing hazardous substances are
labelled with this symbol to indicate that disposal in household waste is
forbidden. The abbreviations for heavy metals in batteries are: Cd = Cadmium,
Hg = Mercury, Pb = Lead (name on (rechargeable) batteries, e.g. below the
trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold. You
thus fulfil your statutory obligations and contribute to environmental
protection.
Batteries/rechargeable batteries that are disposed of should be protected
against short circuit and their exposed terminals should be covered completely
with insulating tape before disposal.
Even empty batteries/rechargeable batteries can contain residual energy that
may cause them to swell, burst, catch fire or explode in the event of a short
circuit.
Technical data
Rated voltage …………………………………3 V, 2x Mignon batteries (AA)
Data backup …………………………………..Decoupling capacitor storage
……………………………………………………..Time: approx. 7 days
……………………………………………………..Settings: < 10 years
Protection rating ……………………………..IP20
Temperature adjustment range ………….+1 to 70 °C
Temperature display range ……………….0 to +40 °C
Display accuracy …………………………….0.5 °C
Display accuracy …………………………….+/-0.5 °C
Display size (W x H) ………………………..62 x 47 mm
Operating/storage conditions …………….1 to +70 °C; < 85% RH (non-condensing)
Thermostat dimensions (W x H x D) ……86 x 86 x 30 mm
Thermostat weight …………………………..120 g (without batteries)
14.2 Switching module
Rated voltage …………………………………90 to 240 V/AC, 50/60 Hz
Connected load/current ……………………max. 3000 W (resistive load)
……………………………………………………..max. 2000 W (inductive load)
Contact load capacity ………………………16 A, 250 V
Protection rating ……………………………..IP20
Number of switching outputs …………….1
Relay …………………………………………….Normally open
Temperature adjustment range ………….+1 to 70 °C
Sensor probe (external) ……………………NTC (10k) 1%
Operating/storage conditions …………….1 to +70 °C; < 85% RH (non-condensing)
Dimensions (W x H x D) …………………..86 x 86 x 29 mm
Switching module weight ………………….125 g
Transmission/reception frequency ……..433.00 to 433.89 MHz
Transmission power…………………………< 13 dBm
Range ……………………………………………max. 200 m (open field)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240
Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g.
photocopy, microfilming, or the capture in electronic data processing systems
require the prior written approval by the editor. Reprinting, also in part, is
prohibited.
This publication represent the technical status at the time of printing.
Copyright 2023 by Conrad Electronic SE.
*2735095_v2_0423_02_dh_m_enhttp://www.conrad.com/downloads
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>