The PM Module, model 7591-01, is a handheld device that can be used in conjunction with the OmniTrakTM Smart Station to provide mmediate feedback on the conditions in the immediate area. It allows users to take measurements, create reports, and analyze  ata to help improve conditions. The module is not designed to be worn on the body or placed near an individual’s head. The device operates on AC/DC power and comes with a USB-C cable for charging.

Specifications

  • PM Sensor Specifications:
    • Number Concentration Range: 0 to 3’000
    • Number Concentration Size Range: 0 to 1’000
    • Number Concentration Precision for PM0.5, PM1, and PM2.5: —
    • Number Concentration Precision for PM4, PM10: 0.3 to 0.5, 0.5 to 1.0, 1.0 to 2.5, 2.5 to 4.0, 4.0 to 10.0
    • Mass Concentration Range: —
    • Number Concentration Size Range for PM1 and PM2.5: 0.3 to 0.5, 0.5 to 1.0, 1.0 to 2.5
    • Number Concentration Precision for PM4, PM10: —
  • AC and DC Power Requirements:
    • AC/DC Power Supply: 100 to 240 VAC, 50/60 Hz, 0.3A
    • Device Input Power: 5 VDC, 2A, 10W
  • Environmental/Installation Requirements:
    • Maximum Altitude: 3000 meters (10,000 feet)
    • Pollution Degree: 2
    • Installation Category: I
    • Operating Temperature: —
    • Storage Temperature: —
    • Humidity: 0% – 95% (non-condensing)
  • Compliance:
    • FCC ID: 2A22JOTMODULES
    • IC ID: 28101-OTMODULES

Product Usage Instructions

  1. Power On: Hold down the power button on the left side of the module for 1 second.
  2. Power Off: Hold down the power button on the left side of the module until you see a light sequence of green, yellow, red. That indicates the module is off.
  3. Charging:
    • Plug the USB-C cable into the bottom of the module and into a power source.
    • A blinking green light indicates that the module is charging.
  4. The module will appear in the list on the Smart Station. If not, hit Refresh.
  5. Press the desired module on the screen to connect to the Smart Station. A green check mark indicates a successful connection.
  6. Press Done.
  7. Now you’re ready to take measurements using the PM Module.
  8. Battery Disposal: Dispose of the battery in accordance with local rules and regulations.

Note: All modules are shipped in ‘Sleep Mode’ by default to protect the battery. To power on the module for the first time, plug it into a power source and charge it for a few minutes. This process is only required once.

To comply with RF exposure requirements, the device and its antenna may be operated near a person’s body and extremities, but must be operated with a separation distance of at least 20 cm from all person’s head.

Operation Instructions

  1. Power On: Hold down power button on left side of module for 1 second.
  2. Power Off: Hold down power button on left side of module until you see a light sequence of green, yellow, red. That indicates module is off.
  3. Charging: Plug USB-C into bottom of module and into power source. A blinking green light indicates module is charging.
  4. Connecting to a Smart Station: Power on module by holding down the circle on the left for 1 second. A blue LED light will start to blink indicating Bluetooth® is on.
  5. The module will appear in the list on the Smart Station. If not, hit Refresh.
  6. Press desired module on screen to connect to Smart Station. A green check mark indicates a successful connection.
  7. Press Done

Now you’re ready to take measurements.
The OmniTrak™ Smart Station can be used in conjunction with any OmniTrak™ Module to provide immediate feedback as to the conditions in the immediate area. Take measurements, create reports, and analyze data provided to help improve conditions. This instrument is a handheld device, not to be worn on the body, or near an individual’s head.
Dispose of battery in accordance with local rules and regulations.

What’s Included in the Box

  • Device
  • USB-C Cable

NOTE : All modules, by default, are shipped in ‘Sleep Mode’ to protect the battery. It will not be possible to power on the Module, using the side button, until ‘Sleep Mode’ is disabled. To disable, plug the module into a power source and charge the module for a few minutes. This process is required only once.

SOECIFIFICATION

OmniTrak-7591-01-PM-Module-fig-
\(1\)OmniTrak-7591-01-PM-Module-fig- \(2\)

Compliance

FCC ID:
2A22JOTMODULES
IC ID:
28101-OTMODULES

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. T his device must accept any interference received, including interference that may cause undesired operation.

Per FCC 15.21 Changes or modififications not expressly approved by TSI will void the product warranty and may void the user’s authority to operate the equipment

Compliance
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device.

To satisfy RF exposure requirements, this device and its antenna may be operated near a persons body and the extremities, but must be operated with a separation distance of at least 20 cm from all person’s head.

WARNING

  • DO NOT attempt to replace the battery in this instrument.
  • DO NOT abuse the battery in any way as the battery may rupture or catch fire.
  • DO NOT use a substitute or nonrechargeable battery in this instrument.
  • DO NOT short-circuit, incinerate, dismantle or mutilate Lithium ion batteries
  • DO NOT expose to water or heat.
  • DO NOT use any battery which shows signs of damage, such as bulging, swelling, a swollen plastic wrap, liquid in the plastic wrap, etc.

LASER WARNING

  • OmniTrak™ Modules are Class 1 laser-based instruments.
  • During normal operation, you will not be exposed to laser radiation.
  • DO NOT open the OmniTrak™ Module when it is powered ON.
  • You will not be exposed to the laser radiation when the OmniTrak™ Module is disassembled.
  • The PM sensor has a laser inside it. DO NOT open the PM sensor inside OmniTrak Module when the OmniTrak Module is powered.

TSI Incorporated – Visit our website www.tsi.com for more information.

  • USA Tel: +1 800 874 2811
  • UK Tel: +44 149 4 459200
  • France Tel: +33 1 41 19 21 99
  • Germany Tel: +49 241 523030
  • India Tel: +91 80 67877200
  • China Tel: +86 10 8219 7688
  • Singapore Tel: +65 6595 6388

Specifications are subject to change without notice. Wi-Fi is a registered trademark of Wi-Fi Alliance®.
The Bluetooth® word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. TSI, and the TSI logo are registered trademarks of TSI Incorporated in the United States and may be protected under other country’s trademark registrations.
Printed in U.S.A.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals