ZAHEES ZM2033 Electronic Bidet Toilet Instructions
- June 12, 2024
- ZAHEES
Table of Contents
ZAHEES ZM2033 Electronic Bidet Toilet
PARTS IDENTIFICATION
Left side
Right side
Installation of ceramic toilet
Water supply angle valve installation
- Draw drain outlet centerline on the floor, install angle valve at proper position on wall according to dimension of toilet. 10″ off center is preferred.
Cardboard installation
- Align cardboard with the centerline of drain outlet.
- Outline with pencil or tape according to cardboard.
- Please mark the position of flange bolts.
Mounting bracket installation
- Assemble the mounting L-Bracket with bolts and then install them to the pre-install flange plate on the ground and tighten with nuts.
Ceramic toilet installation
- Install wax ring onto drain outlet of toilet.
- Carefully lower toilet into place directly according to the outline position.
Attention:
This toilet is team-lift recommend, also seat should be in open position to
aid in installation.
- Install Screw through Plastic Insert and into the opening on the side of the toilet. Tighten Screw into L-Bracket being careful not to over tighten.
Silicone caulking application
- Apply Silicone caulking to the edge of toilet base, wipe away any excess.
Note:
Please clean the drain outlet; Please make sure ceramic toilet outlet sits
perfectly on drain outlet.
Installation of hose
- Connect water inlet and angle valve with new hose.
Before Installation
-
Turn on the angle valve
Check thread connection, make sure no leakage is found.
-
Power Connection
• Insert power line leakage protection plug into the power socket, press the reset switch, plug indicator lights on indicating that the power is on.
Tips:
Press electric leakage test button prior to usage, the reset switch pops up indicating that the leakage protection function is normal.
Press the TEST button (then RESET button) every month to assure proper operation.
Suitable for the product with leakage protection plug.
Please refer to the actual product. -
Self-inspection
1. The main unit buzzer rings first “click”, power indicator (POWER) and Energy-conservation indicator (ENERGY SAVER) flash. Power indicator lights on and Energy-conservation indicator
2. gets off to start self-inspection.
The main unit buzzer rings second “click” to indicate finish of self- inspection, power indictator lights on, and Energy-conservation indicator keeps off.
3. Start function mode for normal usage.
Daily maintenance
Main unit care and maintenace
-
Shut off power supply at maintenance.
-
Turn the seat upward open, press down the button located on the right side of main unit and pull out the seat. Wipe the stain with a soft damp cloth.
-
Safety self- inspection
After cleaning, re-connect the toilet with the power supply
Spray nozzle maintenance and care
-
Nozzle self-cleaning
The nozzle will be cleaning automatically before washing and after washing -
Nozzle manual-cleaning
Open the lip and seat , then rotate the knob in the clockwise direction .
The nozzle will extend forward.
-
Use soft cloth or soft brush to clean
Do not pull or push the wand, to avoid damage.
-
top cleaning
Press the knob then the nozzle will go back .
Emergency Troubleshooting
Electricity and water supply cut-off
-
Power failure
•Press the reset switch
-
Water failure
•Put around 8L water into a barrel and flush the bowl of ceramic.
Note: Avoid water spilling from bowl.
Failure of remote control
-
Operate the knob on bidet seat to perform.
-
Battery replacement
• Remove the cover of the remote control
• Put into two pieces of AAA battery , then reinstall the cover
-
Battery of toilet replacement or installing
• Put up the electronic bidet from hind side
• Recover the cover of b attery
• Put into one piece of 6LR61 battery Recover the cover
The illustration of main unit keys
Rear wash Be seated then rotate the knob in the clockwise direction
Front wash Be seated then rotate the knob in the anticlockwise direction
Stop / Power Press it to stop washing or drying. Not be seated keeping presing the knob ,it will be power off. Keeping pressing again ,it will be power on again .
Foot controller
ZM2033
When the foot is close to it , flushing will be worked
ZM2035
When the foot is close to it , the lip will be opened .
When close to it again , the seat will be opened.
When close to it third time , the lip and seat will be closed and flushed