GENERAL WARNINGS

RISK OF CHOKING!
Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as these ma- terials pose a choking hazard.
RISK of ELECTRIC SHOCK!
This device contains electronic components that operate via a power source (ac adaptor). Only use the device as described in the manual; otherwise, you run the risk of an electric shock.
RISK of FIRE/EXPLOSION!
Do not expose the device to high temperatures.
Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion.
! RISK of property damage!
Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.
EC DECLARATION OF CONFORMITY
**** Hereby, Bresser GmbH declares that the equipment type with part number:
7004030 is in compliance with Directive:
2014/30/EU and 2014/35/EU. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/7004030/CE/7004030_CE.pdf

BRESSER 7004030 CO2 Monitor Smile XXL - iconMANUAL DOWNLOAD:

www.bresser.de/P7004030

SCOPE OF DELIVERY

| CO2 Air Quality Monitor Smile XXL
---|---
| Wall plugs (x4)
| Wall mounting screws (x4)
| AC/DC power adapter
| Instruction Manual

TECHNICAL DATA

Power supply AC/DC power adapter DC 9V 2000 mA
Response Time Within 10 seconds of any change in CO2
Carbon dioxide measurement range 0 – 9999 PPM
Accuracy + 70 PPM ±3% readings
Resolution 1 PPM
Temperature measuring range _10° to +100°C
Temperature resolution 0.1°C
Temperature accuracy ±0.3°C
Humidity measuring range 0 to 99.9% RH
Humidity resolution 0.1%
Humidity accuracy ±3%
Work condition 0 – 50° C (0 – 90% RH)
Storage condition -30 – 70° C (0 – 90% RH)
Dimensions 388x288x43 mm
Weight 1.435 kg

FRONT

  1. Graphical display of current CO2 level.
    ?Poor: 1200-9999PPM
    ? Good: 600-1100PPM
    ? Excellent: 0-500PPM

  2. PPM Value. PPM stands for
    “parts per million” and shows
    the concentration of carbon
    dioxide in the ambient air.

  3. Temperature

  4. Humidity

BRESSER 7004030 CO2 Monitor Smile XXL - display

BACK

  1. MODE button
    Set carbon dioxide concentration alarm value

  2. ▲  button
    Increase the alarm value

  3. ▼button
    Decrease the alarm value

  4.   button
    Alarm on/off

  5. °C/°F button
    Switch Celsius/Fahrenheit

  6. Horizontal wall mounting holes

  7. Vertical wall mounting holes

  8.  DC power interface

BRESSER 7004030 CO2 Monitor Smile XXL - button

CO² LEVEL:

CO2 level Status Description
250 — 350ppm Outside Normal outdoor air level.
350-1000ppm Well ventilated, Ideal Typical level indoors with good

ventilation. 1000 ppm =
Recommended maximum level in a closed room. Con- sidered maximum comfort level in many countries.
1000-1200ppm| Under ventilated| Poor air quality – requires ventilation.
General drowsiness, discomfort and odors.
1200-2000ppm| Very under ventilated| Fatigue and sleepiness may set in. Intensify ventilation measures!
2000-5000ppm| Very poorly ventilated| Danger! You may experience severe headaches, vomit- ing/nausea, and dizziness within 20 minutes.
above 5000ppm| Totally unacceptable| Danger! Headache and dizziness in 5 to 10 minutes.
Increased risk for health damage by prolonged exposure.

WALL MOUNT
Use the wall plugs and wall mounting screws to attach the device to your wall in horizontal or vertical position.
CHARGING / START-UP
Insert the DC connector into the connection socket (8) of the device. Insert the mains plug into the power outlet. The device is energized directly and begins preheating. The LCD displays a countdown of 7 seconds. The buttons are not operational during this time. Once the countdown is finished the device enters the normal measurement state.
SETTINGS MODE
Press the MODE button to enter the carbon dioxide alarm settings mode. Press▲ or ▼to choose the PPM value when the alarm should start. Press the MODE button to confirm and exit the settings mode.
The default alarm value is 1200 PPM.
CARBON DIOXIDE ALARM
Press the Alarm button to activate or deactivate the carbon dioxide alarm. When you hear a small beep sound, then the alarm is activated. The alarm will sound once the concentration of carbon dioxide reaches the alarm value. Press the alarm button again during an active alarm to deactivate the alarm sound.

CLEANING AND MAINTENANCE

Before cleaning the device, disconnect it from the power supply (disconnect power adapter)! Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.

DISPOSAL

Dispose of the packaging materials properly, according to their type, such as paper or cardboard.
Contact your local waste-disposal service or environmental authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage! As per Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.

WARRANTY

The regular warranty period is 2 years and begins on the day of purchase. To benefi t from an extended voluntary warranty period as stated on the gift box, registration on our website is required.
You can consult the full warranty terms as well as information on extending the warranty period and details of our services at www.bresser.de/warranty_terms.

Service

Please contact the service centre first for any questions regarding the product or claims, preferably by e-mail.
E-Mail: service@bresseruk.com
Telephone:
+44 1342 837 098
BRESSER UK Ltd.
Suite 3G, Eden House
Enterprise Way Edenbridge, Kent TN8 6HF
United Kingdom
Number charged at local rates in the UK (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.
Contact
Bresser GmbH
Gutenbergstraße 2
46414 Rhede · Germany
www.bresser.de
  @BresserEurope

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals