INKBIRD IAM-T1 Smart Indoor Air Quality Monitor Instruction Manual
- June 12, 2024
- INKBIRD
Table of Contents
- IAM-T1 Smart Indoor Air Quality Monitor
- OVERVIEW
- Technical Specifications
- Installation Instructions
- Product Diagram
- Key Definitions
- Buzzer Sond Description
- Cleaning and Maintanece
- Troubleshooting Guide
- FCC Requirement
- Caustomer Service
- APP Installation & Connection
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
IAM-T1 Smart Indoor Air Quality Monitor I
nstruction Manual
IAM-T1 Smart Indoor Air Quality Monitor
Please keep this manual properly for reference. You can also scan the QR code below to visit our official website for product usage videos. For any usage issues, please feel free to contact us at support@inkbird.com. https://inkbird.com/pages/download
OVERVIEW
Among various indoor gases, CO2 is the gas that best represents indoor air quality. High concentrations of CO2 can cause headaches, fatigue, rapid heartbeat, and shortness of breath. Prolonged exposure to high levels of CO2 may have negative effects on the respiratory system and may even lead to diseases such as trachetis and pneumonia Therefore, itis vitally important to maintain an appropriate range of indoor CO2 concentration for the sake of health, That’s why we have introduced IAM-T1, Smart Indoor Air Quality Monitor that helps you stay safe and healthy.
-
The first choice for family air health and safety
Equipped with the world’s leading SENSEAIR air sensor IM-T1 ensures high accuracy, high performance, and ultra-low power consumption, with precise and stable detection of indoor air quality. -
Four-year ultra-long battery life
With utra-ow power consumption sensors and low-powerink screens, using 2 large capacty A alkaline batteries, AM-T1 can operate stably for 4 years with a 10-minute sampling interval, without frequent replacement of batteries, which is simple and convenient. -
Intelligent use with Bluetooth 5.0 and mobile APP
AIAMATI can locally record 30 days of data, which can be transmitted to mobille APP through Bluetooth for backup and visualization of data in the form of charts. Besides, it allows users to observe, compare, and analyze monitoring data over the past two years. -
Clear and intuitive electronic ink screen
With high-contrast 180° no-deackangle visual experience, IAM-T1 provides accurate and clear CO2 concentration level indication, making it easy for users to understand the current air quality.
Technical Specifications
- Smart Indoor Air Quality Monitor
- Model: |AM-T1
- Power Source: 2* AA alkaline batteries (2500mah)
- Screen: Low-power-consumption and Clear Electronic Ink Screen
- Networking Configuration: Low-power-consumption Bluetooth 5.0
- Bluetooth range: 100m/328ft (no obstructions)
- Sampling Interval: 1min/2min/Smin/10min (default 1min)
- Application: INKBIRD APP
- Dimensions: 758030mm
- Weight: 1389
Senso r performance | Range | Resolution | Accuracy |
---|---|---|---|
CO2 concentration | 0 – 9999 ppm | 1 ppm | t 30 ppm * |
t 3 % of reading
Temperature| 0 – 50 °C| 0.1 °C (0.1 °F)| t0.3 °C (t0.5 °F)
Relative humidity| 0 – 85 %| 1%| ± 3 %
Atmospheric pressure| 600 -1100 hPa| 1 hPa| -2 hPa / +3 hPa
*002 measurement accuracyis provided for arange 0 .. 5000 ppmtermperature 15 .. 35 °C (59.. 95°F) andireative humicity O.80 % Accuracy above 5000 ppr is 10 % of reading,but not quaranteed since itis extrapolated form the calbrated range.
Installation Instructions
Battery Installation
Please install the supplied batteries correctly according to the + and “*
marks on the battery compartment.
Product
Installation
Product Diagram
Auto-Calibration icon
— the smart auto-calibration is turned on.
— Noicon s displayed, the smart auto-calibration is turned off
Bluetooth icon
— Bluetooth is turned on but not in the connecting
— App connecting
— Nojicon is displayed Bluetooth turned OFF Buzzer Switch Icon
Displayed——buzzer sound on the device s turned on;
Disappears——the buzzer sound is turned off.
Note: The buzzer’s settings can be adjusted using the INKBIRD app!
cO2 Concentration Value (ppm)
€02 concentration level in ppm (parts per million). €02 Threshold Level Indicator
When the progress bar is within the green part , the CO2 concentration level
is ina good state (<1000 ppm).
When the progress bar is within the yellow part, the CO2
concentration level is ina medium state (1000~1400 ppm)
When the progress bar is within the red part , the CO2 concentration level is
in an unhealthy state (>1400 ppm),
Note: These are default thresholds that can be reconfigured using the
INKBIRD app. Temperature (‘C/F)
Temperature: the temperature of the air in C or °F
Note:See the Key Definitions in this manual to understand how to change
temperature unit.
Relative Humidity (%)
the relative humidity of the air, expressed in RH%
Startup Interface
When the device is powered on with a battery installed, it will be
initialized. Please wait for a few seconds! €02 Alarm
Interface
When the CO2 level exceeds the preset alarm value, the display on the screen
will become black and white. The alarm is triggered by the unhealthy state
(red) by default. The alarm value can be customized through the App.
Low Battery Interface
If the battery is exhausted, replace it as soon as possible. Try to use 2*M
alkaline batteries with a higher capacity. (z—2500mah) Device Calibration
Interfac
When the manual calibration on the device is enabled, the screen enters this
interface. The device must be calibrated in the prompted CO2 environment (like
420 ppm). During the calibration process, humans, animals, and plants are not
allowed to approach the device.
Too-low Ambient Temperature Interface
This interface will be displayed when the ambient temperature is lower than
0°C. The temperature measurement range of the device is 0-50°C, and
temperature beyond the range will affect the normal operation of the device.
CO2 Detection Error
The detected 002 concentration may exceed 9999 ppm. Please do not exhale
directly into the device, as the gas concentration from the human body can be
as high as 30000 – 50000 ppm. Please use this device within the detection
range.
Key Definitions
Button:
Short press: press it to change the temperature unit, ‘C/F.
‘Tip: When Bluetooth is connecting, press it to pair
Long press: Press and hold the button for 5 seconds to unbind the device and
restore
it to factory settings.
Bluetooth Switch:
ON: Bluetooth is enabled
OFF: Bluetooth is disabled
Wall mount hole
Buzzer Sond Description
- Low Battery Warning: When the device enters the low power state, it will emit a beep and display the low battery icon.
- Out-of-limit Data Alarm: When the CO2 concentration exceeds the default alarm value, the device will beep twice per second, and the beep wil stop after 5 seconds.
- Settings on the App:
- Turn off the buzzer;
- Sound one time: When the sampled value continuously exceeds the alarm value within a period, the buzzer will sound at the first sampling time when the preset alarm value s judged to be exceeded
- Sound every time: When the sampled value continuously exceeds the alarm value within a period, the buzzer will sound every time it is judged that the preset alarm value is exceeded.
Cleaning and Maintanece
- Do not expose this product to water, do not place it in high-temperature environments over 50°C, and keep it away from fire sources.
- This product s precise measuring instrument, do not disassemble it by yourself.
- Donot place this product in an environment full of dust or corrosive gas for measurement
- Donot directly expose this product to the sun for long,
Troubleshooting Guide
ISSUES | POSSIBLE SOLUTIONS |
---|---|
The value of CO2/ temperature/humidity did not change for a long time | 1.The |
device samples once per minute at the fastest. Please wait for it. If you need
to change the sampling time to 2min/5min/10min, please set it on the App. The
longer the sample interval, the longer the battery life.
2.At the same place, and when the air environment is slightly flowing, the CO2
concentration is relatively stable, so the value will not change rapidly. This
is a stable and accurate method of air quality detection.
The device displays ‘ error: 1050’| 1.It may be caused by humans
exhaling/blowing into the device. The CO2 concentration of the gas emitted by
humans can be as high as 30000-50000 ppm.
2.It may be that the device stays close to a special place where high
concentrations of CO2 are emitted, such as furnaces, smoking, and other high
concentrations of smoke (within 50cm). Do not leave the device continuously in
an area with high smoke concentration_ Note that this device supports a CO2
concentration detection range of 0-9999 PPM.
CO2 calibration| The monitor is calibrated at the factory. However, the user
can carry out CO2 calibration manually when needed The general recommendation
is to calibrate once a year, but more often if it is used in dusty
environments. During the manual calibration, the device must be exposed to
fresh outdoor air. Keep a distance of at least one meter from the device
during the calibration process – no humans, animals, or plants should be
closer to the device during calibration.
FCC Requirement
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by tuming the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
~ Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20cm between the radiator & your body. This transmitter
must not be colocated or operating in conjunction with any other antenna or
transmitter.
Caustomer Service
‘This item carries a 1-year warranty against defects in either components or
workmanship.
During this period, products that prove to be defective wil, at the discretion
of INKBIRD, be either repaired or replaced without charge. For any problems in
use, please feel free to contact us at support@inkbird.com. We will do our
best to help you
APP Installation & Connection
1.1INKBIRD APP https://inkbird.com/pages/app- download
Search the INKBIRD App from Google Play or App Store to get it for free, or you can scan the QR code below to download it directly.
NOTE:
- Youri0S devices must be running i0S 12.0 or above to download the app smoothly.
- Your android devics must be running android 7.1 or above to download the app smoothly.
- APP Location Permission Requirement: We need to obtain your location information to discover and add nearby devices. INKBIRD promises to keep your location information strictly confidential. And your location information will only be used for the location function of the App and will not be collected, used, or disclosed to any third party.
Your privacy s very important to us. We will abide by relevant laws and regulations and take reasonable security measures to protect your information security.
1.2 Registration
Step1 : Registering an account is necessary before using the INKBIRD app
for the first time
Step2: Open the app, select your Country/Region, and a verification code
will be sent to you.
Step3: Enter the verification code to confirm your identity, and the
registration is complete.
1.3 How to Connect
- Turn on the bluetooth on your phone and be careful to put the device as close as possible to the smartphone
- Open the INKBIRD app and Click “+” on the top right corner to add a device. Then, follow the app instructions to complete the bluetooth connection. Be careful to put the device as close as possible to the smartphone
- Please check the above steps and try again if pairing fails;
INKBIRD TECH.C.L.
support@inkbird.com
Factory address: 6th Floor, Building 713, Pengji Liantang Industrial Area,
NO.2 Pengxing Road, Luohu District, Shenzhen, China
Office address: Room 1803, Guowe Building, NO.68 Guowei Road,
Xianhu Community, Liantang, Luohu District, Shenzhen, China