Nidec EM15 Excitation Module User Manual

June 12, 2024
Nidec

Nidec EM15 Excitation Module

Nidec EM15 Excitation Module

This manual concerns the EM15 which you have just purchased.
We wish to draw your attention to the contents of this maintenance manual.

SAFETY MEASURES

Before using your EM15 for the first time, it is important to read the whole of this installation and maintenance manual.

All necessary operations and interventions on this machine must be performed by a qualified technician.

Our technical support service will be pleased to provide any additional information you may require.

The various operations described in this manual are accompanied by recommendations or symbols to alert the user to potential risks of accidents. It is vital that you understand an take notice of the following warning symbols.

The EM15 can be incorporated in a ECmarked machine.

Symbol
Warning symbol for an operation capable of damaging or destroying the machine or surrounding equipment.


Warning symbol for general danger to personnel.


Warning symbol for electrical danger to personnel.

All such operations performed on the EM15 should be undertaken by personnel trained in the commissioning, servicing and maintenance of electrical and mechanical components.

© 2023 Meteors Leroy-Somer SAS
Share Capital: 32,239,235 €, RCS Angouleme 338 567 258.
We reserve the right to modify the characteristics of this product at any time in order to incorporate the latest technological developments. The information contained in this document may therefore be changed without notice.
This document may not be reproduced in any form without prior authorization.
All brands and models have been registered and patents applied for.

GENERAL DESCRIPTION

The EM15 Excitation Module is a power electronics component designed to provide excitation current to the generator that is controlled by an External Voltage Regulator (EVR).
Leroy-Somer is leading the power generation marketplace with power solutions engineered to deliver unmatched flexibility, expandability, reliability and cost-effectiveness.

Features
  • Over-excitation protection – limit can be adjusted via a potentiometer (IEXC)

  • Green status LED indicating unit is powered on

  • Red status LED indicating excitation current limiting (flashing) or shutdown (solid)
    The External Voltage Regulator system offers:

  • Automatic Voltage Regulation (AVR)

  • Programmable stability settings

  • Soft start control with an adjustable time setting in AVR control mode

  • Dual Slope Under Frequency (Volts / Hz) regulation

  • Three-phase or single-phase generator voltage (RMS) sensing/regulation in AVR mode
    The EVR can also offer:

  • Power Factor Regulation (PF)

  • Generator paralleling with reactive droop compensation

  • Line drop compensation

Complete system integration

The EM15 is designed and factory tested to work seamlessly with Leroy-Somer alternators using Shunt Excitation (SE), AREP Excitation (AREP) or Permanent Magnet (PMG) excitation systems.

SPECIFICATIONS

Electrical

Generator excitation types| Shunt excitation / AREP excitation / Permanent Magnet (PMG)
---|---
Max. continuous field current output| 7 Amps
Max. forcing field current output| 15 Vrms
Max. AC voltage input (X1:X2, Z1:Z2)| 240 Vrms

Environmental
Operating temperature range -40 °C (−40 °F) to +70 °C (+158 °F)
Storage temperature range -40 °C (−40 °F) to +85 °C (+185 °F)
Relative humidity tolerance 95% non-condensing humidity
Salt spray 5% salt (NaCl) solution for 120 hrs
Vibration 4.5 G-rms, 24-2000 Hz in 3 orthogonal planes
Electromagnetic compatibility RF Immunity (radiated & conducted) RF Emissions

(radiated & conducted) Electrical transients
Weight| 800 g ± 30 g
Power consumption (at max. continuous rating)| <600 VA

Conformity
UL UL Recognized (U.S. and Canada) File No. E334232
CE integration certificate In conformity with the applicable requirements of

the following standards:
EN 50178
EN 60204-1
EN 61000-6-2
EN 61000-6-4

OVER-EXCITATION PROTECTION

If a short-circuit fault occurs at the generator terminals, the EM15 will allow the excitation current to rise to the upper limit value set by the adjustment potentiometer (max. 15 A).

The excitation current will be clamped at the upper limit value for 10 seconds (fixed internally).
After 10 seconds, the excitation current is reduced to a value of 10% of the potentiometer setting.
Over-excitation Protection

DIMENSIONS

(in mm)

Dimensions

EXAMPLE CONNECTION DIAGRAM

(Permanent Magnet Excitation)

Example Connection Diagram

Notes:

  1. External fuses required with EM15 module
  2. Recommend 250V, 10A fast acting fuses

2-way Connector Functions:

Label Function
F+ Exciter Field Positive Output
F- Exciter Field Negative Output

3-way Connector Functions:

Label Function
Shield Excitation Command Shield
CS+ Excitation Command Positive Input
CS- Excitation Command Negative

Input

4-way Connector Functions (PMG Excitation):

Label Function
X2 Excitation Power Supply Input

(PMG Phase B)
Z1| Not Connected
X1| Excitation Power Supply Input
(PMG Phase A)
Z2| Excitation Power Supply Input
(PMG Phase C)

4-way Connector Functions (Shunt Excitation):

Label Function
X2 Excitation Power Supply Input

(Single-phase)
Z1| Not Connected
X1| Excitation Power Supply Input
(Single-phase)
Z2| Not Connected

4-way Connector Functions (AREP Excitation):

Label Function
X2 Excitation Power Supply Input

(Aux Winding 1 – Positive)
Z1| Excitation Power Supply Input
(Aux Winding 2 – Positive)
X1| Excitation Power Supply Input
(Aux Winding 1 – Negative)
Z2| Excitation Power Supply Input
(Aux Winding 2 – Negative)

Service & Support

Our worldwide service network of over 80 facilities is at your service.

This local presence is our guarantee for fast and efficient repair, support and maintenance services.

Trust your alternator maintenance and support to electric power generation experts.
Our field personnel are 100% qualified and fully trained to operate in all environments and on all machine types.

We have a deep understanding of alternator operation, providing the best value service to optimise your cost of ownership.

Where we can help:
Service & Support

Connect with us at:

Social Icon

QR code
Scan the code or go to:
http://www.lrsm.co/support

Customer Service

Contact us:
Americas: +1 (507) 625 4011
EMEA: +33 238 609 908
Asia Pacific: +65 6250 8488
China: +86 591 8837 3010
India: +91 806 726 4867

service.epg@leroy-somer.com

https://www.leroy-somer.com/epg

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals