The MSI-6360 Retrofit Kit is designed to update MSI-6260 and older generations of the MSI-6360 to the most current configuration. It includes various parts and components to ensure optimal performance and compatibility with the latest technology.

Product Specifications:

Item No. Part No. Description Qty
1 215841 Front Casting Assembly 6360 1
2 215934 Bulkhead Assembly 6360 1
3 149724 O-ring Assembly Front Casting Paw/Trans-Weigh 2
4 198913 Conn, IP67, Euro Field Wireable, 4 Cond, Female Straight
PG-9 1
5 145998 Screw SH 3/8-16 x 1-1/4 SS 3
6 162185 Conn, M12 4 Pin Male Field Wireable 6-8mm OD Straight IP67 1
7 133597 Screw Seal 3/8-16 x 1-1/4 SS Drilled Head 1
8 145962 Screw RH 4 x 1/4 U Type Drive Plated 2
9 146565 Screw FH 6-32 x 5/8 Phil SS 2
10 149679 Tag Serial Number 1
11 215948 Label Descriptive 6360 1

For more detailed information, refer to the user manual
available at www.ricelake.com/manuals.
Warranty information can be found at www.ricelake.com/warranties.

Product Usage Instructions

Removing the Existi ng Front Casting

Follow the steps below to remove the existing front casting:

  1. Refer to Figure 2 for visual guidance.
  2. Disconnect any cables or wires connected to the front casting.
  3. Unscrew and remove the front casting screws.
  4. Gently lift and remove the front casting from the unit.

Rewiring Load Cell Cable

Follow the steps below to rewire the load cell cable:

  1. Refer to Table 2 for load cell cable conductor color and function information.
  2. Connect the load cell cable conductors to the corresponding color-coded pins on the connector, as shown in Figure 3.

Rewiring the Battery Cable

Follow the steps below to rewire the battery cable:

  1. Refer to Table 3 for battery cable conductor color and function information.
  2. Connect the battery cable conductors to the corresponding pins on the connector, as shown in Figure 4.

Reassembling the Unit

Follow the steps below to reassemble the unit:

  1. Place the O-ring in the groove on the bulkhead of the supplied front casting. Ensure the bulkhead is correctly aligned on the front casting.
  2. Plug the updated cables into the cable connectors on the bulkhead. The load cell cable should connect to the male connector, and the power cable should connect to the female connector.
  3. Remove the old serial tag on the mid casting to comply with NTEP regulations. The new serial tag is located on the front casting.
  4. Reinstall the battery casting, securing it with the retained hardware.
  5. Refer to the technical manual (PN 216128) for the calibration procedure to calibrate the unit.

For any further assistance or inquiries, please visit our website at www.ricelake.com.

The MSI-6360 Retrofit Kit updates MSI-6260 and older generations of the MSI-6360 to the most current configuration. Generation information is located on the serial tag.
Manuals are available from Rice Lake Weighing Systems at www.ricelake.com/manuals
Warranty information is available at www.ricelake.com/warranties

Description

RICE-LAKE MSI-6360-Port-A-Weigh-Crane-Scale-FIG-
\(1\)

Item No. Part No. Description Qty
1 215841 Front Casting Assembly 6360 1
2 215934 Bulkhead Assembly 6360 1
3 149724 O-ring Assembly Front Casting Paw/Trans-Weigh 2
4 198913 Conn, IP67, Euro Field Wireable, 4 Cond, Female Straight PG-9 1
5 145998 Screw SH 3/8-16 x 1-1/4 SS 3
6 162185 Conn, M12 4 Pin Male Field Wireable 6-8mm OD Straight IP67 1
7 133597 Screw Seal 3/8-16 x 1-1/4 SS Drilled Head 1
  145962 Screw RH 4 x 1/4 U Type Drive Plated 2
  146565 Screw FH 6-32 x 5/8 Phil SS 2
  149679 Tag Serial Number 1
  215948 Label Descriptive 6360 1

Removing the Existing Front Casting

WARNING : Ensure that all power has been removed prior to starting the procedure.

  1. Turn the MSI-6360 off.
  2. Remove the front casting by loosening the screws securing it. See Figure 2.
  3. Unplug the load cell and power cables from the front casting or bulkhead. Discard casting and hardware.
  4. With one hand, support the battery access cover.
  5. Release the two latches holding the battery access cover.
  6. Carefully lower the cover while holding the battery in place, it could be loose and fall causing damage.
  7. Remove the battery by pulling straight back.
  8. Close the cover and secure with latches.
  9. Remove the battery casting by loosening the screws securing it. Retain for re-installation

Rewiring Load Cell Cable

  1. Locate the cable coming out of the load cell.
  2. Cut the connector off as close to the connector as possible.
  3.  Strip the cable jacket as needed to allow 1/2 – 3/4 inch of exposed conductors, Red, Green, White and Black.
  4. Cut the shield/drain wire flush with the end of jacket.
  5. Strip the Red, Green, White and Black wires approximately 1/4 inch and tin with solder.
  6. Connect the wires to the connector together as shown in Table 2. and Figure 3.RICE-LAKE MSI-6360-Port-A-Weigh-Crane-Scale-FIG- \(3\)
    L/C Cable Conductor Color| Function| Connector Pin Number
    ---|---|---
    Red| +Excitation| 1
    Black| -Excitation| 2
    Green| +Signal| 3
    White| -Signal| 4

Rewiring the Battery Cable

  1. Locate the power cable coming from the inside of the battery casting.
  2. Cut the connector off the battery cable as close to the connector as possible.
  3. Strip the cable jacket as needed to allow 1/2 – 3/4 inch of exposed conductors, Red and Black.
  4. Cut the shield/drain wire flush with the end of jacket.
  5. Strip the Red and Back wires approximately 1/4 inch and tin with solder.
  6. Connect wire to the connector as shown in Table 3. and Figure 4.RICE-LAKE MSI-6360-Port-A-Weigh-Crane-Scale-FIG- \(4\)
    Battery Cable Conductor Color| Function| 198913 Connector Pin Number
    ---|---|---
    Red| + Battery| 1
    Black| – Battery| 2
    –| Not Used| 3
    –| Not Used| 4

Reassembling the Unit

  • Place the o-ring in the groove on the bulkhead of the supplied front casting. Ensure bulkhead is correctly aligned on the front casting.

  • Plug the updated cables into the cable connectors on the bulkhead. Load cell cable connects to the male connector and power cable connects to the female connector.

  • Place the front casting assembly on mid-casting assembly and secure with the supplied 3/8 inch drive head screws, torqued to 20–25 ft-lbs (see Figure 2 on page 2).
    IMPORTANT : To comply with NTEP, remove the old serial tag on the mid casting. The new serial tag is located on the front casting.

  • Reinstall the battery casting securing with the retained hardware.

  • Calibrate the unit, see the technical manual (PN 216128) for the calibration procedure.

© Rice Lake Weighing Systems Content subject to change without notice.
230 W. Coleman St. • Rice Lake, WI 54868 • USA USA: 800-472-6703 • International: +1-715-234-9171
www.ricelake.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

RICE LAKE User Manuals

Related Manuals