SHELLY-PRO-1 1 Circuit Wi-Fi Relay Switch User Guide
- June 6, 2024
- Shelly
Table of Contents
SHELLY-PRO-1 1 Circuit Wi-Fi Relay Switch User Guide
Read before use
This document contains important technical and safety information about the
device, its safety use and installation.
CAUTION! Before beginning the installation, please read this guide and
any other documents accompanying the device carefully and completely. Failure
to follow the installation procedures could lead to malfunction, danger to
your health and life, violation of the law or refusal of legal and/or
commercial guarantee (if any). Alterio Robotics EOOD is not responsible for
any loss or damage in case of incorrect installation or improper operation of
this device due to failure of following the user and safety instructions in
this guide.
Product Introduction
Shelly® is a line of innovative microprocessor-managed devices, which allow
remote control of electric appliances through a mobile phone, tablet, PC, or
home automation system. Shelly® devices can work standalone in a local Wi-Fi
network or they can also be operated through cloud home automation services.
Shelly® devices can be accessed, controlled and monitored remotely from any
place the User has Internet connectivity, as long as the devices are connected
to a Wi-Fi router and the Internet. Shelly® devices have integrated web
servers, through which the user may adjust, control and monitor them. The
cloud function could be used, if it is activated through the web server of the
device or the settings in the Shelly Cloud mobile application. The user can
register and access Shelly Cloud using either Android or iOS mobile
application, or with any internet browser at https://my.shelly.cloud/
Shelly® Devices have two Wi-Fi modes – Access Point (AP) and Client mode (CM).
To operate in Client Mode, a Wi-Fi router must be located within the range of
the device. Devices can communicate directly with other Wi-Fi devices through
HTTP protocol. An API is provided by Allterco Robotics EOOD. For more
information, please visit: https://shelly-api-docs.shelly.cloud/#shelly-
family-overview
Control your home with your voice
Shelly® devices are compatible with Amazon Echo and Google Home supported functionalities. Please see our step-by-step guide on: https://shelly.cloud/support/compatibility/
Shelly® Pro Series
Shelly® Pro series is a line of devices suitable for homes, offices, retail
stores, manufacturing facilities, and other buildings. Shelly® Pro devices are
DIN mountable inside the breaker box, and highly suitable for new building
construction. All Shelly® Pro devices can be controlled and monitored through
Wi-Fi and LAN connections. Bluetooth connection can be used for the inclusion
process.
Legend:
Device terminals:
- N: Neutral terminal
- L: Live (110-240V) terminal
- +12 : 12V (10.5V to 13.5V) DC power supply terminal
- SW1 : Switch (controlling O*) input terminal
- SW2 : Switch* input terminal
- O : Load circuit output terminal
- I : Load circuit input terminal
Wires:
- L: Live (110-240V) wire
- L1(A) : Load circuit live (110-240V) wire
- L2(B) : Device power supply live (110-240V) wire
- + : 12 V DC power supply positive wire
- -: 12 V DC power supply negative wire
- Can be reconfigured
Installation Instructions
The Shelly Pro 1 smart relay (the Device) by Allterco Robotics EOOD is
intended to be mounted into a standard switchboard on DIN rail, next to the
circuit breakers in order to control the electric power through it . Shelly
can work as a standalone device or as an accessory to a home automation
controller.
CAUTION! Do not install the device at a place that is possible to get
wet.
CAUTION! Danger of electrocution. Mounting / Installation of the Device
to the power grid has to be performed with caution, by a qualified
electrician.
CAUTION! Danger of electrocution. Every change in the connections has to
be done after ensuring there is no voltage present at the Device terminals.
CAUTION! Do not connect the Device to appliances exceeding the given max
load!
CAUTION! Use the Device only with a power grid and appliances which
comply with all applicable regulations. A short circuit in the power grid or
any appliance connected to the Device may damage the Device.
CAUTION! Connect the Device only in the way shown in these instructions.
Any other method could cause damage and/or injury.
CAUTION! he Device may be connected to and may control electric circuits
and appliances only if they comply with the respective standards and safety
norms.
RECOMMENDATION Connect the Device using solid single-core cables with
increased insulation heat resistance not less than PVC T105°C. Connect the
Device to the power grid and install it in the switchboard as shown in the
schemes and following the Safety Instructions. Before starting
installing/mounting the Device, wire check that the breakers are turned off
and there is no voltage on their terminals. This can be done with a phase
meter or mustimeter. When you are sure that there is no voltage, you can
proceed to wiring the cables. If you are using AC for the Device and the load
circuit (fig.1), connect the N terminal to the Neutral wire and the L terminal
to the Device power supply circuit breaker. Connect the 2 switch circuits to
the S1 and S2 input terminals and the Device power supply circuit breaker.
Connect the load circuit to the O terminal and the Neutral wire. Connect the I
terminal to the load circuit breaker. Two different phases can be used for the
load circuit and the Device power supply circuit. If you are using AC to power
the Device, but want to switch a DC load circuit (fig.2), connect the N
terminal to the Neutral wire and the L terminal to the circuit breaker.
Connect the 2 switch circuits to the S1 and S2 input terminals and the circuit
breaker. Connect the load circuit to the O terminal and one of the load
circuit power supply wires. Connect the I terminal to the other load circuit
power supply wire.
CAUTION! The load circuit voltage should not exceed 30 V DC and the
current should not exceed 12 A. If you are using 12 V DC to power the Device,
but want to switch an AC load circuit (fig. 3), connect the positive wire to
the +12 terminal and the negative wire to the L terminal. Connect the 2 switch
circuits to the S1 and S2 input terminals and the negative wire. Connect the
load circuit to the O terminal and the Neutral wire. Connect the I terminal to
the circuit breaker. If you are using 12 V DC to power the Device and want to
switch a DC load circuit (fig. 4), connect the Device power supply positive
wire to the +12 terminal and the Device power supply negative wire to the L
terminal. Connect the 2 switch circuits to the S1 and S2 input terminals and
the Device power supply negative wire. Connect the load circuit to the O
terminal and one of the load circuit power supply wires. Connect the I
terminal to the other load circuit power supply wire.
CAUTION! The load circuit voltage should not exceed 30 V DC and the
current should not exceed 12 A.
RECOMMENDATION For inductive loads, which cause voltage spikes during
switching, such as electrical motors, fans, vacuum cleaners, refrigerators and
similar ones, RC snubber (0.1µF / 100 / 1/2W / 600V AC) should be wired in
parallel with the load. RC snubbers can purchased at
https://shop.shelly.cloud/rc-snubber-wifi-smart-home-automation.
Initial Inclusion
You can choose to use Shelly® with the Shelly Cloud mobile application and
Shelly Cloud service. Instructions on how to connect your device to the Cloud
and control it through the Shelly App can be found in the “App Guide” included
in the box. You can also familiarize yourself with the instructions for
Management and Control through the embedded Web interface at 192.168.33.1 in
the Wi-Fi network, created by the Device.
CAUTION! Do not allow children to play with the button/ switch connected
to the Device. Keep the Devices for remote control of Shelly (mobile phones,
tablets, PCs) away from children.
Specifications
- Dry contact: Yes
- Power supply: 110-240 V AC, 50/60 Hz; 12V DC (DC range: +10.5 V ÷ 13.5 V, 250mA)
- Max switching current: 16 A
- DC output: 0 V ÷ 30 V; 12A
- Dimensions (HxWxL): 68.5×18.5×89.5 mm
- Mounting – DIN rail
- Wi-Fi – YES
- Bluetooth – YES
- LAN – YES
- Temperature Protection – YES
- Scripting (mjs) – YES
- MQTT – YES
- CoAP – No
- URL Actions – 20
- Scheduling – 50
- Add-on support – YES
- CPU – ESP32
- Flash – 8MB
- Operational range: (depending on terrain and building structure): up to 50 m outdoors, up to 30 m indoors
- Electrical consumption: < 3 W
- Working temperature: 0°C – 40°C
- Controlled elements: 1 electrical circuits (max 30 V in DC mode).
- Controlling elements: 1 relay
- Radio signal power: 1mW
- Radio protocol: Wi-Fi 802.11 b/g/n
- Frequency Wi-Fi : 2412-2472 Hz; (Max. 2495 MHz)
- Frequency Bluetooth: TX/RX: 2402-2480 MHz (Max. 2483.5 MHz)
- RF output Wi-Fi: <20 dBm · RF output Bluetooth: <5 dBm
LED INDICATORS
Power (red): Red light indicator will be on if power is connected. Wi-
Fi (blue): Blue light indicator will be on if the Device is in AP mode.
Wi-Fi (red): Red light indicator will be on if the Device is in STA mode
and not connected to a local Wi-Fi network.
Wi-Fi (yellow): Yellow light indicator will be on if the Device is in STA
mode and connected to the local Wi-Fi network. Not connected to Shelly Cloud
or Shelly Cloud disabled.
Wi-Fi (green): Green light indicator will be on if the Device is in STA
mode and connected to the local Wi-Fi network and to the Shelly Cloud.
Wi-Fi (flashing): The light indicator will be flashing Red/Blue if OTA
update is in progress.
LAN (green): Green light indicator will be on if LAN is connected.
Output (red): Red light indicator will be on if the Output relay is
closed.
DECLARATION OF CONFORMITY
Hereby, Allterco Robotics EOOD declares that the radio equipment type Shelly
Pro 1 is in compliance with Directive 2014/53/ EU, 2014/35/EU, 2014/30/EU,
2011/65/EU. The full text of the EU declaration of conformity is available at
the following internet address https://shelly.cloud/knowledge-base/devices
/shelly-pro-1/
Manufacturer: Allterco Robotics EOOD
Address: Bulgaria, Sofia, 1407, 103 Cherni vrah Blvd.
Tel.: +359 2 988 7435
E-mail: support@shelly.cloud
Web: http://www.shelly.cloud Changes in the contact data are published by
the Manufacturer at the official website of the Device
http://www.shelly.cloud All rights to trademark Shelly® and other
intellectual rights associated with this Device belong to Allterco Robotics
EOOD.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>