Product Information
The MINI-SA 2 is a standalone proximity reader with the following features:
- Mounting: Can be easily mounted on a surface
- Dimensions: Compact size for easy installation
- DC/AC: Supports both DC and AC power supply
- Programming Flowchart: Provides step-by-step instructions for enrolling and deleting cards
FEATURES
- Standalone Proximity Reader
- Operates on 12-24V DC; 15-24V AC
- Reads EM4002 compatible tags and cards
- 4000 Users (cards)
- Programming with Master and Delete Card
- Card can be deleted even if it is lost or stolen (Shadow Card)
- 1 Exit button input
- 1 Relay (1A /30V AC/DC)
- Adjustable Door relay Time(1-250sec, 0-ON/OFF (Toggle) Mode)
- Read Range: up to 10cm
- Resin potted electronics
- Dipswitch for enrollment of Master and Delete Card
- Cable, 0.5 m
- Tamper switch for higher security
- Visual and audio feedback
- Current Consumption: 60 mA at 12VDC 40 mA at 24VDC
- Dustproof and waterproof (IP66)
DIMENSIONS
MOUNTING
The reader should not be mounted against metal surface. If there is an installation where the metal surface cannot be avoided, isolation base between the reader and the metal must be used. The thickness of the isolation base should be determined with test.
WIRING
APPLICATION DIAGRAM
DC: External DC Power Supply for EM Lock
AC: External AC Power Supply for strike
Note: Strike can be connected to DC
PROGRAMMING FLOWCHART
Enroll Master and Delete Card
- Turn OFF the power supply
- Push dip switch no.1 in position OFF.
- Turn ON the power supply. All three LEDs will blink continuously.
- Enter Master Card. Red and Yellow LED will blink.
- Enter Delete Card. Red LED will blink.
- Turn OFF the power supply.
- Put the dip switch in position ON.
NOTE: Changing Master and Delete Card is done with the same procedure. Old Master and Delete Card are deleted automatically.
Enroll a User
- Cards can be programmed individually or as a block of sequential cards.
- For each User, 2 cards are being programmed: 1 User Card and 1 Shadow Card.
- The User Card is issued to the User and the Shadow Card is kept on safe place.
- If the User Card is lost or stolen, the Shadow Card will be used to delete the corresponding User Card.
NOTE: Shadow card can be issued for 1 user or for group of users. In both
cases, write the name of the user on the shadow card and keep all of the
shadow cards on safe place.
NOTE: If more than one user is associated to same shadow card, deleting
with that shadow card will result with deletion of all the Users associated to
that shadow card.
NOTE: If a shadow card needs to be changed, just enroll the same User
with different Shadow card.
Enroll block of user cards
NOTE: The block of User cards can be maximum 100 Cards.
Delete a User (with the user card)
Delete a User (with the shadow user card)
Delete ALL Users
NOTE: 7 seconds maximum time for deleting all 4000 users
Set Door Relay Time
NOTE: Door relay time can be set in the range of 1 to 250 seconds.
Set Door Relay in Toggle (ON/OFF) Mode