Edvivi FFN7935BK 20 Inch Industrial Style Ceiling Fan User Guide
- June 12, 2024
- Edvivi
Table of Contents
Edvivi FFN7935BK 20 Inch Industrial Style Ceiling Fan
Safety Information
- To reduce the risk or electric shock the electricity has been turned off at the circuit breaker or fuse box before begin.
- All wiring must be in accordance with the National Electrical Code NASJ/NFPA 70-1999 and local electrical codes. Electrical installation should be performed by a qualified licensed electrician . The weight of the fan is 9.6kg (21.2b).to reduce the risk of fire, electric shock, or personal Injury. mount to outlet box marked acceptable for fan support of 22.6 kg (50 lbs) or less and use mounting screws provided with the outlet box. most outlet boxes commonly used for the support of luminaires are not acceptable for fan support and may need to be replaced. consult a qualified electrician If In doubt.
- The fan must be mounted with a minimum of 7 ft. (2m) clearance from the trailing edge of the blades to the floor.
- Do not operate the reversing switch while the fan blades are in motion. You must turn the fan off and stop the blades before you reverse the blade direction.
- Do not place objects in the path of the blades.
- To avoid personal injury or damage to the fan and other items use caution when working around or cleaning the fan.
- Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL-listed and marked suitable for use with the model fan you are installing. Switches must be UL General Use Switches. Refer to the instructions packaged with the light kits and switches for proper assembly.
- After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
- All setscrews must be checked and retightened where necessary before installation
- WARNING: TO reduce the risk of personal injury, do not bend the blade brackets (also referred to as flanges) during assembly or after installation. Do not insert objects in the path of the blades.
- WARNING: Remove the rubber motor stops on the bottom of the fan before installing the blades testing the motor.
- WARNING: To reduce the risk or fire or electric shock.do not use this fan with any solid-state speed control device.
- WARNING: To avoid possible electric shock, turn the electricity off at the main fuse box before wiring. It you feel you do not have enough electrical wiring knowledge or experience, contact a licensed electrician.
- WARNING: Electrical diagrams are for reference only. Optional use of any light kit shall be UL-listed and marked suitable for use with this fan.
- WARNING: To reduce the risk of fire, electric shock, or personal injury. mount to outlet box marked ” Acceptable for fan support of 35 lbs.(15.9 kg)or less.” and use the screws provided with the outlet box.
Warranty
The supplier assure that The fan motor is from defects in workmanship and
material present at time of shipment from the factory for a lifetime after the
date of purchase by the original purchaser. The supplier also warrants that
all other fan parts. Excluding any glass or acrylic blades.to be free from
defects in workmanship and material at the time of shipment from the factory
for a period of. We agree to correct such defects without charge or at our
option replace with a comparable or superior model if the product is returned.
To obtain warranty service. you must present a copy of the receipts proof of
purchase. All costs of removing and reinstalling the product are your
responsibility. Damage to any part. such as by accident ,misuse ,improper
installation or by affixing any accessories ,is not covered by this warranty.
Because of varying climatic conditions this warranty does not cover any
changes in brass finish ,including rusting, pitting, corroding, tarnishing. Or
peeling. Brass finish of this type give their longest useful life when
protected from varying weather conditions. A certain amount of •wobbles normal
and should not be consider a defect. Servicing performed by unauthorized
persons shall render the warranty invalid. There is no other express warranty.
Hereby disclaims any and all warranties. Including but not limited to those of
merchantability and fitness for a particular purpose to the extent permitted
by law. The duration of any implied warranty which cannot be disclaimed is
limited to the time period as specified in the express warranty. Some states
do not allow a limitation on how long an implied warranty lasts.so the above
limitation may not apply to you. The retailer shall not be liable for
incidental, consequential, or special damages arising out of or in connection
with product use or performance except as may otherwise be accorded by law.
Some states do not allow the exclusion of incidental or consequential
damages.so the above exclusion or limitation may not apply to you. This
warranty gives specific legal rights. And you may also have other rights which
vary from state to state. This warranty supersedes all prior warranties.
Shipping costs for any return of products as part of a claim on the warranty
must be paid by the customer.
Pre-Installation
Specification
Size| Speed| Volts| Amps| Watts| CFM| RPM| Net Weight| Gross
Weight
| Cubic
Feet
---|---|---|---|---|---|---|---|---|---
20in| Low| 120| 0.21| 11.1| 465| 411| 11.2LB
5.1KG| 13.7LB
6.2KG| 5.1cu.ft.
Medium| 0.35| 30.5| 630| 616
High| 0.48| 58| 1310| 1205
The above data are for reference only, Actually the motor speed of each ceiling fan is a little different. Any products, Subject to actual products as standard.
NOTE: These are approximate measures. They do not U Include the amps and wattage used by the light kit.
TOOLS REQUIRED
SAFETY PRECAUTION
IMPORTANT: PLEASE READ BEFORE INSTALLATION. I
- Do not connect this remote control ceiling fan to regulator or dimmer switch.
- installation must be carried out by a qualified wiring installer.
- Turn off the electrical mains at the circuit breaker fuse box.
- Do not use power supply other than 110-120V~ 60Hz.
- This appliance must be earthed.
- When mounting the fan, ensure that the safety wire is loop across the ceiling mounting hook.
- The ceiling mounting hook must be able to withhold a min. weight of 60kg.
- The ceiling fan must be mounted at a min. height of 7.5 feet/ 2.3m of clearance from the floor.
- Do not place any objects in the path of the blades.
- When all electrical connections are done, store all wires neatly.
- Make sure that all screws and connection are tightly screwed and secured.
- Children should be supervised to ensure that they do not play with the appliance.
- Ensure that the fan is switched off from the supply mains before removing the guard.
WARNING
This product is designed to use only those parts supplied with this product
and/or accessories designated specifically for use with this product. Using
parts and/or accessories not designated for use with this product could result
in personal injury or property damage.
NOTE: Regulator Dimmer switch The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without prior notice for further improvements.
PARTS &ACCESSORIES
Installation of the hanging bracket(suspension part)
Install a hanger on the ceiling
For wooden ceiling, use wood screw to drill on the wooden beam or the
“junction box” to fix the hanging bracket (selection is made according to
actual requirements of the customers).
TEP 1A-WOODEN CEILING
SWITCH OFF THE ELECTRICAL MAINS AT THE CIRCUIT BREAKER FUSE BOX.
- Use the Mounting Bracket (A) as a guide, mark the spots where the 4 Self Tapping Screws (B) will be drilled.
- Remove the Mounting Bracket (A), drill 4 holes for 3MM diameter, install the mounting bracket onto wooden ceiling with the 4 Self Tapping Screws (B) & Washers (C) .
IMPORTANT: SCREWS MUST BE TIGHTENED TILL SNUG
For concrete ceiling, use the percussion bit with diameter 8mm to drill holes according to the length of expansion screws. Then use the attached expansion screws to fix the hanging bracket onto the ceiling (selection is made according to actual requirements of the customers).
STEP 2A-CONCRETE CEILING
SWITCH OFF THE ELECTRICAL MAINS AT THE CIRCUIT BREAKER FUSE BOX.
- Use the Mounting Bracket (A) as a guide, mark the spots where the 4 Expansion Bolts (B) will be drilled.
- Remove the Mounting Bracket (A), drill 4 holes and insert 4 Expansion Bolts (2) into the concrete ceiling, install the mounting bracket and secure with Flat Washers (C), Spring Washers (D) and Nuts (E).
IMPORTANT: SCREWS & NUTS MUST BE
Remove the hanger from the motor.
Note: According to the ceiling of different materials, use different
screws to fix the hanging bracket.
Don’t fix the hanging bracket on the wood ceiling less than 12MM to prevent
danger caused by loosening of screws.
After the hanging bracket is completed, ensure that it can withstand the
tension test of more than 68KG for safety.
INSTALLATION INSTRUCTION
Install suspension system
- Let’s pass the ball/donor assembly through the metal hook
- Let’s pass the ball/donor assembly through the coupler cover.
- Finish.
Assembling the fan
- Loosen, but do not remove, the two setscrews on the col a on top of the motor housing.
- Align the holes at the bottom of the down rod with the holes in the collar on top of the motor housing.
- Carefully insert the hanger pin through the holes in the collar and down rod. Be careful not to jam the hanger pin against the wiring inside the downrod.
- Insert the locking pin through the hole near the end of the hanger pin until it snaps into its locked position.
- Re-tighten the two setscrews on the collar on top of the motor housing.
Selection of hanger pipes
- Use hanger pipes at an appropriate height based on the height of the ceiling.
- This ceiling fan is provided with the hanger pipe at the length of 10 inches and 20 inches.
The bottom of the fan lamp must be ensure 2.3 meters
Install suspension system
- Remove the hanging pin and r-locking pin at the bottom
- Let’s pass the down rod assembly through the canopy.
- Pass the down rod assembly through the Coupler cover
Install the bulbs
- Choose the bulb that closes act the role of the lifting pipe and set them aside for later use. screw bulb inside lamp holder.
Wiring diagram
WARNING: Each wire not supplied with this fan is designed to accept up to one 12-gauge house wire and two wires from the fan. If you have larger than 12-gauge house wiring or more than one house wire to connect to the fan wiring. consult an electrician for the proper size wire nuts to use.
WARNING: Remove the rubber motor stops on the bottom of fan before installing the blades or testing the motor.
IMPORTANT: Use the plastic wire connectors (BB) supplied with your fan. Secure the connectors with electrical tape and ensure there are no loose strands or connections.
Install remote control
- Carefully push the canopy to the bottom of the mounting bracket, make two sliding holes aligned to the two prominent screws on the mounting bracket, and then turn clockwise until tight.
- Push the canopy ring to the bottom of the canopy, slide the inner holes aligned to the two prominent screws on the mounting bracket again, and turn the canopy ring clockwise until tight
Preparing for mounting
- Remove the mounting bracket from the canopy by loosening the two canopy screws located in the L shaped slots.
- Remove and save the two canopy screws in the round holes. This will enable you to remove the mounting bracket
TRANSMITTER FUNCTION
Forward
Fan rotates anti-clockwise creating a downward airflow delivering a cooling
effect.
Suitable for hot weather condition or air-conditioned condition
Reverse
Fan rotates clockwise creating an upward airflow moving warm air off the
ceiling areas. This function
works best at lower fan speed.
Suitable for cold weather or air-conditioned condition.
Transmitter Holder
Care and cleaning
WARNING: Make sure the power is off before cleaning your fan.
- Because of the fan’s natural movement, some connections may become loose. Check the support connections, brackets ,and blade attachments twice a year. Make sure they are secure. It is not necessary to remove the fan from the celling.
- Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning, as this could damage the motor or the wood, or possibly cause an electrical shock. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plating is sealed with a lacquer to minimize discoloration or tarnishing.
- You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty. Cover small scratches with a light application of shoe polish.
- You do not need to oil your fan. The motor has permanently-lubricated sealed ball bearings.
Troubleshooting
Problem | Solution |
---|---|
The fan will not start. |
- Check the main and branch circuit fuses or breakers.
- Check the line wire connections to the fan and switch wire connections in the switch housing.
The fan will not start.|
- Ensure all motor housing screws are snug.
- Ensure the screws that attach the fan blade bracket to the motor hub are tight.
- Ensure the wire nut connections are not ratting against each other or the interior wall of the switch housing.
- Allow a 24-hour “breaking in” period. Most noises associated with a new fan disappear during this time.
- If you are using the Ceiling Fan light kit, ensure the screws securing the glassware are tight.
- Check that the light bulbs are also secure.
- Ensure the canopy is a short distance from the ceiling. It should not touch the ceiling.
- Ensure your outlet box is secure and rubber isolator pads were used between the mounting plate and outlet box.
The fan wobbles.|
- Check that all blade and blade arm screws are secure.
- Most fan wobble problems are caused when blade levels are unequal. Check this level by selecting a point on the ceiling above the tip of one of the blades. Measure from a point on the center of each blade to the point on the ceiling. Measure this distance. Rotate the fan until the next blade is positioned for measurement.
- Repeatfor each blade. Any measurement deviation should be within 1/8 in. Run the fan for ten minutes. If the fan continues to wobble please contact Customer Service and a balancing kit will be sent to you
Thank you for purchasing our products.
Have a nice day