FOX ESS HV25 BMS Box Installation Guide
- June 12, 2024
- FOX-ESS
Table of Contents
FOX ESS HV25 BMS Box
Tools Required
The following tools will be required to install the Mira-BMS and the battery.
Packing List
For Mira-HV25
No. | Description | No. | Description |
---|---|---|---|
A | Communication cable (0.21m) | E | Fixing bracket |
B | Battery Power cable (0.19m) | F | Installation guide |
C | Grounding cable (0.19m) | G | User Manual |
D | Mouning screw pack |
Note : item E is provide separately, not including in battery package. Please contact your dealer if you do not have it.
For Mira-BMS
Note : item F is provide separately, not including in battery package. Please contact your dealer if you do not have it.
Terminals
For Mira-BOX :
For Mira-HV25 :
Installation Steps
Note : Batteries with different color SN label cannot be mixed in one system
-
Step 1
Place the front bracket and back bracket as shown below. -
Step 2
Insert the battery module into the bracket from front horizontally, and tighten the four screws on the side. -
Step 3
Locate the brackets for the second battery on top of the first pair of the bracket and fasten the connecting button on the side. -
Step 4
Insert the battery module into the bracket from front horizontally, and tighten the four screws on the side
Note:
Max. 4 pieces battery per stack. Please make sure each system including 1
Mira-BMS.
Battery modules less than 4 pieces:
Battery modules more than 4 pieces:
Wiring Steps
Battery power cable:
- Step 1 : Connect the power cable starting from the first battery module in series with other battery modules (Orange opposite, black negative). A ‘click’ sound indicates the connections are secured. The positive and negative connection of the battery cable is shown in below.
- Step 2 : Measure voltage value: After all battery modules are connected in series, use a multimeter to measure the DC voltage on DC terminal. The total voltage should be N *52+10V (N is the total number of battery module). Please refer to the picture below for voltage test.
Communication cable connection
- Step 1 : Take the main positive cable (two orange plugs), the main negative line (two black plugs) to connect the Mira-BMS.
- Step 2 : Then connect the MODULE on the Mira-BMS to the CAN-1 of the first battery module, connect the CAN-2 of the previous battery module to CAN-1 of the next battery module, leave the last module’ s CAN-2 vacant. Wiring shall be connected in the sequence as shown in below.
Grounding cable:
Connect the grounding cable to ensure that all batteries are grounded. Wiring
shall be connected in the sequence as shown in below.
System Start Up
Mira-BMS operation:
- Normal mode : Turn on DC switch first, then press ‘POWER’ button.
- Black start : (No grid connected) press the ‘B-start’ switch, turn on DC switch, and then press the ‘POWER’ switch.
Startup steps:
After powering on, all the green lights flash once, and then the running water
lights flash once. The light on the Mira-HV25 comes on after a delay, not at
the same time as the light on the BMS