V3700 IBM Storwize Storage System
User Guide
IBM Storwize V3700 for Lenovo
Product Guide
V3700 IBM Storwize Storage System
Abstract
IBM Storwize V3700 Storage System for Lenovo (Machine Type 6099) is a member
of the IBM Storwize family of disk systems. By using IBM Storwize V7000
Storage System and IBM SAN Volume Controller functions, interoperability, and
management tools, Storwize V3700 delivers innovation and new levels of storage
efficiency with ease of use in an entry-level disk system to enable
organizations to overcome their storage challenges.
Storwize V3700 Storage System features two node canisters, with 4 GB cache per
canister upgradeable to 8 GB, in a compact, 2U, 19-inch rack mount enclosure.
A 6 Gb SAS and 1 Gb iSCSI connectivity is standard, with an option for 8 Gb
Fiber Channel (FC) or 10 iSCSI or Fiber Channel over Ethernet (Foe)
connectivity.
Storwize V3700 supports up to 240 drives with up to nine external expansion
units. It also offers flexible drive configurations with the choice of
2.5-inch and 3.5inch drive form factors, 10 K or 15 K rpm SAS and 7.2 K rpm NL
SAS hard disk drives (HDDs), and SAS solid-state drives (SSDs).
Change History
Changes in the June 21 update:
- Added 3.2 TB SAS SSD
- Updated warranty upgrades
- Removed withdrawn Brocade FC SAN Switches for Lenovo
- Removed withdrawn Blade Center adapters and I/O modules
- Added 0U Power distribution units (PDUs)
- Removed withdrawn PDUs
- Updated formatting
Introduction
IBM Storwize V3700 Storage System for Lenovo (Machine Type 6099) is a member
of the IBM Storwize family of disk systems. By using IBM Storwize V7000
Storage System and IBM SAN Volume Controller functions, interoperability, and
management tools, Storwize V3700 delivers innovation and new levels of storage
efficiency with ease of use in an entry-level disk system to enable
organizations to overcome their storage challenges.
Storwize V3700 Storage System features two node canisters, with 4 GB cache per
canister upgradeable to 8 GB, in a compact, 2U, 19-inch rack mount enclosure.
A 6 Gb SAS and 1 Gb iSCSI connectivity is standard, with an option for 8 Gb
Fiber Channel (FC) or 10 iSCSI or Fiber Channel over Ethernet (Foe) Storwize
V3700 supports up to 240 drives with up to nine external expansion units. It
also offers flexible drive configurations with the choice of 2.5-inch and
3.5inch drive form factors, 10 K or 15 K rpm SAS and 7.2 K rpm NL SAS hard
disk drives (HDDs), and SAS solid-state drives (SSDs).
The Storwize V3700 SFF enclosure is shown in the following figure.
Did you know?
Storwize V3700 provides small and midsized organizations with the ability to
consolidate and share data at an affordable price, while utilizing advanced
software capabilities that often are found in more expensive systems.
Storwize V3700 can be scaled up to 960 TB of raw storage capacity.
Storwize V3700 offers hybrid block storage connectivity with support for 6 Gb
SAS, 1 Gb iSCSI, and 10 Gb iSCSI or Foe or 8 Gb FC at the same time.
Key features
The Storwize V3700 storage system provides the following key features and benefits:
-
Scalable, modular storage with dual-active intelligent array node canisters with up to 8 GB cache per canister.
-
Flexible host connectivity to match diverse client needs with support for 6 Gb SAS and 1 Gb iSCSI connectivity standard, with optional 10 Gb iSCSI or Foe, 8 Gb FC, or extra 6 Gb SAS or 1 Gb iSCSI connectivity.
-
6 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) or 24x 2.5-inch small form factor (SFF) drives in the controller unit; scalable up to 120 LFF drives per system with the attachment of LFF expansion units (12x LFF drives each) or up to 240 SFF drives per system with the attachment of SFF expansion unit (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
-
Flexibility in storing data on high-performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors within a single system to perfectly meet performance and capacity requirements for various workloads.
-
Rich set of standard functions are available at no extra cost, including virtualized internal storage, snapshots, thin provisioning, data migration, and data replication.
-
Optional licensed functions, including higher number of snapshots for added scalability, Turbo performance, Easy Tier, and remote mirroring.
-
VMware vSphere Virtual Volumes (Val) integration brings advanced storage management functions to the virtual machine level for finer VM storage service level control and policy-driven automation.
Note: Val integration feature requires IBM Spectrum Control Base Edition for Lenovo that can be downloaded from http://www.ibm.com/support/fixcentral. -
Intuitive, web-based GUI for easy system set up and management.
-
Extensive interoperability with support for most major server platforms and operating systems.
-
Conforms to applicable Network Equipment Building System (NEBS) level 3 documents and to applicable European Telecommunications Standards Institute (ETSI) documents
The Storwize V3700 LFF enclosure is shown in the following figure.
The Storwize V3700 supports the complete range of data storage requirements,
from highly utilized applications to high-capacity, low usage applications,
with the flexible choice of drives.
The following 2.5-inch drives are supported:
-
High-performance SSDs: 200 GB, 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS
-
Performance-optimized, enterprise class disk drives:
• 300 GB and 600 GB 15K rpm SAS
• 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS -
High-capacity, archival-class nearline disk drives: 1 TB and 2 TB 7.2K rpm NL SAS
The following 3.5-inch drives are supported: -
Performance-optimized, enterprise class disk drives:
• 300 GB and 600 GB 15K rpm SAS
• 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS -
High-capacity, archival-class nearline disk drives: 3 TB, 4 TB, 6 TB, and 8 TB 7.2K rpm NL SAS
All drives are dual-port and hot-swappable. Drives of the same form factor can
be intermixed within the appropriate enclosure, which provides the flexibility
to address performance and capacity needs within a single enclosure.
Up to nine Storwize V3700 expansion units are supported by a single Storwize
V3700 controller unit. You can intermix 3.5-inch and 2.5-inch expansion units
behind a 3.5-inch or 2.5-inch controller unit. This configuration delivers the
added flexibility to mix 3.5-inch and 2.5-inch drives within a single system.
More drives and expansion units are designed to be dynamically added with
virtually no downtime, which helps to quickly and seamlessly respond to ever-
growing capacity demands.
The Storwize V3700 storage system is designed to offer high levels of system
and data availability with the following technologies:
-
Dual-active, intelligent node canisters with mirrored cache
-
Dual-port drives with automatic drive failure detection and RAID rebuild with global hot spares
-
Hot-swappable and customer replaceable components
-
Automated path failover support for the data path between the server and the drives
The Storwize V3700 supports the following management interfaces: -
Web-based graphical user interface (GUI) via HTTPS that requires only a supported browser (Microsoft Internet Explorer, Google Chrome, or Mozilla Firefox), so there is no need for a separate console or plug-in
-
Command line interface (CLI) via SSH
-
Storage Management Initiative Specification (SMI-S)
-
SNMP and email notifications
Components and connectors
The following figure shows the front of the Storwize V3700 SFF enclosure.
The following figure shows the front of the Storwize V3700 LFF enclosure.
The following figure shows the rear of the Storwize V3700 Controller Unit.
The following figure shows the rear of the Storwize V3700 Expansion Unit.
System specifications
The following table lists the Storwize V3700 storage system specifications.
Table 1. System specifications
Component | Specification |
---|---|
Form factor | Storwize V3700 Controller Unit: 2U rack mount |
Storwize V3700 Expansion Unit: 2U rack mount
Controller unit configuration| Dual controller (known as node canister)
configuration.
RAID levels| RAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6 (Distributed
RAID is supported with the Spectrum Virtualize Software for V3700 version 7.6
onwards, which requires 4 GB to 8 GB cache upgrades).
Controller cache| 8 GB per system (4 GB per node canister) upgradeable to 16
GB (8 GB per node canister). Battery-backed cache protection.
Drive bays| Up to 240 SFF drive bays per storage system:
• 24 SFF drive bays in the controller unit
• 24 SFF drive bays in the expansion unit; up to 9x expansion units
Up to 120 LFF drive bays per storage system:
• 12 LFF drive bays in the controller unit
• 12 LFF drive bays in the expansion unit; up to 9x expansion units
Intermix of SFF and LFF units is supported.
Drive technology| SAS and NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs
is supported.
Drive connectivity| Dual-ported 6 Gb SAS drive attachment infrastructure.
Controller unit with two node canisters (ports per one node canister):
• 24x 6 Gb SAS internal drive ports (SFF enclosure)
• 12x 6 Gb SAS internal drive ports (LFF enclosure)
• 1x 6 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion port for the attachment of
the expansion units
Expansion unit with two expansion canisters (ports per one expansion
canister):
• 24x 6 Gb SAS internal drive ports (SFF enclosure)
• 12x 6 Gb SAS internal drive ports (LFF enclosure)
• 2x 6 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the daisy chained
attachment of the expansion units
Drives| SFF drives:
• 200 GB, 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
• 300 GB and 600 GB 15K rpm SAS HDDs
• 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
• 1 TB and 2 TB 7.2K rpm NL SAS HDDs
LFF drives:
• 300 GB and 600 GB 15K rpm SAS HDDs
• 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
• 3 TB, 4 TB, 6 TB, and 8 TB 7.2K rpm NL SAS HDDs
Storage capacity| Up to 960 TB (120x 8 TB NL SAS HDDs)
Host connectivity| Standard ports (per controller unit with two node
canisters):
• 6x 6 Gb SAS host ports (Mini-SAS HD, SFF-8644) (3 ports per node canister)
• 4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
Optional additional ports on host interface cards (per controller unit with
two node canisters):
• 8x 6 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
• 8x 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
• 4x 10 Gb iSCSI or Foe SFP+ host ports (SW fiber optics, LC) (2 ports per
node canister)
• 8x 8 Gb FC SFP host ports (SW or LW fiber optics, LC) (4 ports per node
canister)
Host operating systems| Microsoft Windows Server 2008 R2, 2012 and 2012 R2;
Red Hat Enterprise Linux (RHEL) 5, 6, and 7; SUSE Linux Enterprise Server
(SLES) 10, 11, and 12; VMware vSphere 5.0, 5.1, 5.5, and 6.0.
Standard software features| Virtualization of internal storage, Thin
Provisioning, One-way Data Migration, Flash Copy snapshots (up to 64 targets).
Optional features| Turbo Performance, Easy Tier, Remote Mirroring, Flash Copy
snapshots (up to 2,040 targets).
Performance (non-Turbo
/ Turbo)*
| • Up to 280,000 / 530,000 cache read IOPS
• Up to 40,000 / 70,000 disk read IOPS
• Up to 9,000 / 15,000 disk write IOPS
• Up to 21,000 / 36,000 disk mixed (70% read/30% write) IOPS
• Up to 3.3 / 5.5 BPS sequential cache read throughput
• Up to 2.0 / 3.8 BPS sequential disk read throughput
• Up to 0.75 / 1.5 BPS sequential disk write throughput
Configuration maximums| Per system:
• Maximum number of storage pools: 1,024
• Maximum number of logical volumes: 2,048
• Maximum logical volume size: 256 TB
• Maximum number of drives in a RAID array: 16
• Maximum number of drives in a distributed RAID array: 128 (including up to 4
spares)
• Maximum number of RAID arrays: 128
Component| Specification**
---|---
| • Maximum number of distributed RAID arrays: 10 Maximum hot spare drives:
No limit
• Maximum number of host ports: 2,048 Maximum number of hosts: 256
• Maximum number of host ports per one host: 32
• Maximum number of snapshots: 2,040 (requires an optional license)
• Maximum number of remote mirroring relationships: 2,048 (requires an
optional license)
Cooling| Redundant cooling with the fan modules that are built into power
supplies.
Power supply| Two redundant hot-swap 735 W AC or 800 W DC power supplies.
Hot-swap parts| Node canisters, expansion canisters, SFP/SFP+ transceivers,
drives, power supplies with fans.
Management interfaces| 2x 1 GbE ports (UTP, RJ-45) in a primary/redundant
configuration. Web-based GUI; SSH CLI; SMI-S; SNMP and email notifications.
Security features| Secure Socket Layer (SSL), Secure Shell (SSH), user level
security, LDAP authentication
Warranty| Three-year customer-replaceable unit and onsite warranty with 9×5
next business day terms. Optional warranty service upgrades are available
through Lenovo: 24×7 coverage, 2-hour or 4-hour response time, 1-year or
2-year warranty extensions, Hard Drive Retention.
Dimensions| Height: 87 mm (3.4 in.); width: 483 mm (19.0 in.); depth: 556 mm
(21.9 in.)
Weight| • 3.5-inch controller unit: Empty: 18.0 kg (39.6 lb); Fully
configured: 28.3 kg (62.2 lb)
• 3.5-inch expansion unit: Empty: 16.4 kg (36.1 lb); Fully configured: 26.7 kg
(58.8 lb)
• 2.5-inch controller unit: Empty: 19.0 kg (41.8 lb); Fully configured: 27.3
kg (60.0 lb)
• 2.5-inch expansion unit: Empty: 16.7 kg (36.7 lb); Fully configured: 25.0 kg
(55.2 lb)
- Performance measurements in systems unconstrained by the number of drives.
** For a detailed list of configuration limits and restrictions for a specific version of the Storwize V3700 software, see the following online document: http://www.ibm.com/support/docview.wss?uid=ssg1S1004388
Controller units
The following table lists the models of the Storwize V3700 controller units.
Table 2. Ordering information for Storwize V3700 controller units
Description| Part number| Machine Type- Model| Feature
code
---|---|---|---
IBM Storwize V3700 3.5-inch Storage Controller Unit| 6099L2C| 6099-12C| ACAN
IBM Storwize V3700 2.5-inch Storage Controller Unit| 6099S2C| 6099-24C| ACBN
IBM Storwize V3700 2.5-inch DC Storage Controller Unit| 6099T2C| 6099-2DC|
ACDJ
- MTM = Machine Type (first four digits) – Model (last three digits and letters)
The part number for the Storwize V3700 controller unit includes the following items:
• One Storwize V3700 LFF or SFF controller unit with two power supplies with cooling modules and with two node canisters
• Two 2.8 m, 10 A/100 – 250 V, C13 to IEC 320-C14 Rack Power Cables (AC- powered models only)
• Two DC power cables (DC-powered models only)
Rack mount hardware kit
Publications package
The Storwize V3700 controller units ship with two node canisters. A node canister provides interfaces for host connectivity, management, and internal drives, and it runs storage management and virtualization software.
Each Storwize V3700 controller unit ships with 8 GB of battery-backed cache (4 GB per node canister) that can be upgraded to 16 GB (8 GB per node canister).
The following table lists cache upgrade option.
Table 3. Cache upgrade option
Description| Part number| Feature code| Maximum quantity
per one controller unit
---|---|---|---
4GB to 8GB Cache Upgrade| 00MJ101| ACHB| 2*
- One per node canister; both node canisters must have the same cache size.
The Storwize V3700 controller units ship with the following host connectivity interfaces:
• 4x Gigabit Ethernet (RJ-45) ports (2 ports per node canister) for 1 Gb iSCSI host connectivity and management
• 6x 6 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (3 ports per node canister) for 6 Gb SAS direct host attachments
Each node canister has one expansion slot for an optional host interface card (HIC). The following host interfaces can be added to the Storwize V3700 controller unit with optional HICs (if HICs are used, two HICs of the same type are required per one controller unit):
• 8x 6 Gb SAS x4 (Mini-SAS HD SFF-8644) ports (4 ports per HIC) for extra SAS connectivity (for a total of 14x 6 Gb SAS ports per controller unit)
• 8x Gbe (RJ-45) ports (4 ports per HIC) for extra iSCSI connectivity (for a total of 12x GbE ports per controller unit)
• 4x 10 Gbe SFP+ ports (2 ports per HIC) with four SW SFP+ optical transceivers (LC connectors) installed for 10 Gb iSCSI or Coe connectivity
• 8x 8 Gb FC SFP ports (4 ports per HIC) with four SW SFP optical transceivers (LC connectors) installed (2 transceivers per HIC) for FC connectivity (a pair of extra 8 Gb FC SW or LW SFP transceivers is available for ordering as an option)
Note: Both node canisters must have the same type of the host interface card installed, and both cards must have SFP/SFP+ modules of the same type, if any.
The following table lists the available host port configurations for the Storwize V3700 controller units.
Table 4. Storwize V3700 controller unit host port configurations
Port type| 6 Gb SAS| 1 Gb iSCSI| 10 Gb iSCSI or
Foe| 8 Gb FC
---|---|---|---|---
Number of ports| Standard configuration
6 (3 per node canister)| 4 (2 per node canister)| –|
| Optional configurations
---|---
14 (7 per node canister)| 4 (2 per node canister)| –| –
6 (3 per node canister)| 12 (2 per node canister)| –| –
6 (3 per node canister)| 4 (2 per node canister)| 4 (2 per node canister)| –
6 (3 per node canister)| 4 (2 per node canister)| –| 8 (4 per node canister)
The following table lists ordering information for the host connectivity
options for the Storwize V3700 controller units.
Table 5. Host connectivity options
Description| Part number| Feature code| Maximum quantity
per one controller unit
---|---|---|---
Host connectivity card options
6Gb SAS 4 Port Host Interface Card| 00MJ093| ACHJ| 2
8Gb FC 4 Port Host Interface Card| 00MJ095| ACHK| 2
1Gb iSCSI 4 Port Host Interface Card| 00MJ097| ACHL| 2
10Gb iSCSI – FCoE 2 Port Host Interface Card| 00MJ099| ACHM| 2
SFP options for 8 Gb FC host interface card (ships with a pair of 8 Gb FC SW
SFP transceivers)
8Gb FC SW SFP Transceivers (Pair)| 00MJ103| ACHS| 2**
8Gb FC LW SFP Transceivers (Pair)| 00MJ105| ACHT| 4***
Cable options for FC, FCoE, and 10 Gb iSCSI host connectivity (AC-powered
models only)
Lenovo 0.5m LC-LC OM3 MMF Cable| 00MN499| ASR5| 8
Lenovo 1m LC-LC OM3 MMF Cable| 00MN502| ASR6| 8
Lenovo 3m LC-LC OM3 MMF Cable| 00MN505| ASR7| 8
Lenovo 5m LC-LC OM3 MMF Cable| 00MN508| ASR8| 8
Lenovo 10m LC-LC OM3 MMF Cable| 00MN511| ASR9| 8
Lenovo 15m LC-LC OM3 MMF Cable| 00MN514| ASRA| 8
Lenovo 25m LC-LC OM3 MMF Cable| 00MN517| ASRB| 8
Lenovo 30m LC-LC OM3 MMF Cable| 00MN520| ASRC| 8
Cable options for FC, FCoE, and 10 Gb iSCSI host connectivity (AC- and DC-
powered models)
1m Fiber Cable (LC) (FC only)| 00MJ168| ACSJ| 8
5m Fiber Cable (LC) (FC only)| 00MJ170| ACSK| 8
10m OM3 Fiber Cable (LC)| 00MJ174| ACSS| 8
25m Fiber Cable (LC) (FC only)| 00MJ172| ACSL| 8
SAS host connectivity cables – Mini-SAS HD (controller) to Mini-SAS (host)
0.6m SAS Cable (mesas HD to mesas)| 00MJ162| ACSA| 14
1.5m SAS Cable (mSAS HD to mSAS)| 00MJ163| ACSB| 14
3m SAS Cable (mSAS HD to mSAS)| 00MJ166| ACSC| 14
SAS host connectivity cables – Mini-SAS HD (controller) to Mini-SAS HD (host)
0.6m SAS Cable (mesas HD to mesas HD)| 00MJ176| ACTA| 14
1.5m SAS Cable (mesas HD to mesas HD)| 00MJ178| ACTB| 14
3m SAS Cable (mesas HD to mesas HD)| 00MJ180| ACTC| 14
- Up to one per node canister; both node canisters must have the same connectivity type.
** Up to one extra SW SFP module pair per 8 Gb FC host interface card in the node canister; both node canisters must have the same connectivity type.
* Up to two LW SFP module pairs per 8 Gb FC host interface card in the node canister; both node canisters must have the same connectivity type. The second pair of LW SFP modules replaces the SW SFP modules that ship standard with the 8 Gb FC HIC.
The Storwize V3700 controller units provide 6 Gb SAS internal dual-port drive connectivity, and each controller unit also has two 6 Gb SAS x4 (Mini-SAS HD SFF8644) ports (1 port per node canister) for 6 Gb SAS expansion unit connectivity.
Expansion units**
The Storwize V3700 controller unit supports attachment of up to nine Storwize V3700 expansion units. Intermix of LFF and SFF units is supported. The enclosures can be added to the system non-disruptively.
The following table lists the models of the Storwize V3700 expansion units.
Table 6. Ordering information for Storwize V3700 expansion units
Description| Part number| Machine Type- Model| Feature
code
---|---|---|---
IBM Storwize V3700 3.5-inch Storage Expansion Unit| 6099LEU| 6099-12E| ACAS
IBM Storwize V3700 2.5-inch Storage Expansion Unit| 6099SEU| 6099-24E| ACBS
IBM Storwize V3700 2.5-inch DC Storage Expansion Unit| 6099TEU| 6099-2DE| ACDS
The part number for the expansion unit includes the following items:
One Storwize V3700 LFF or SFF expansion unit with two power supplies with
cooling modules and with two expansion canisters
• Two 2.8 m, 10 A/100 – 250 V, C13 to IEC 320-C14 Rack Power Cables (AC-
powered models only)
• Two DC power cables (DC-powered models only)
• Rack mount hardware kit
• Publications package
Each Storwize V3700 expansion unit ships with two expansion canisters. Each
expansion canister provides 6 Gb SAS connectivity to the internal drives and
two external 6 Gb SAS x4 ports (Mini-SAS HD SFF-8644 connectors labelled Port
1 and Port 2) that are used for connections to the Storwize V3700 node
canisters and for daisy chaining the expansion units between each other. The
expansion port (Port 4) on the Storwize V3700 node canister is connected to
the Port 1 on the expansion canister. The Port 2 on the expansion canister is
connected to the Port 1 on the expansion canister in the adjacent enclosure,
and so on.
The expansion unit connectivity topology is shown in the following
figure.
The following table lists ordering information for the expansion unit
connectivity options.
Table 7. Expansion unit connectivity options
Description| Part number| Feature code| Maximum quantity
per one expansion unit
---|---|---|---
0.6m SAS Cable (mesas HD to mesas HD)| 00MJ176| ACTA| 2
1.5m SAS Cable (mesas HD to mesas HD)| 00MJ178| ACTB| 2
3m SAS Cable (mesas HD to mesas HD)| 00MJ180| ACTC| 2*
- One cable per expansion canister; two cables are required per each expansion unit.
Drives
The Storwize V3700 LFF controller and expansion units support up to 12 LFF hot-swap drives, and the Storwize V3700 SFF units support up to 24 SFF hot- swap drives.
The following table lists drive options for the Storwize V3700 LFF units.
Table 8. LFF drive options
Description| Part number| Feature code| Maximum quantity
per one LFF unit
---|---|---|---
3.5-inch SAS hot-swap HDDs
300 GB 15,000 rpm 6 Gb SAS 3.5 Inch HDD| 00MJ135| ACKS| 12
600 GB 15,000 rpm 12 Gb SAS 3.5 Inch HDD| 00MJ137| ACKT| 12
900 GB 10,000 rpm 6 Gb SAS 3.5 Inch HDD| 00MJ131| ACKJ| 12
1.2 TB 10,000 rpm 6 Gb SAS 3.5 Inch HDD| 00MJ133| ACKK| 12
1.8 TB 10,000 rpm 12 Gb SAS 3.5 Inch HDD| 00MN524| ASTK| 12
3.5-inch NL SAS hot-swap HDDs
3 TB 7,200 rpm 6 Gb NL SAS 3.5 Inch HDD| 00MJ127| ACKB| 12
4 TB 7,200 rpm 6 Gb NL SAS 3.5 Inch HDD| 00MJ129| ACKC| 12
6 TB 7,200 rpm 12 Gb NL SAS 3.5 Inch HDD| 00MN522| ASTJ| 12
8 TB 7,200 rpm 12 Gb NL SAS 3.5 Inch HDD| 00WC008| AT0T| 12
The following table lists drive options for the Storwize V3700 SFF units.
Table 9. SFF drive options
Description| Part number| Feature code| Maximum quantity
per one SFF unit
---|---|---|---
2.5-inch SAS hot-swap HDDs
300 GB 15,000 rpm 6 Gb SAS 2.5 Inch HDD| 00MJ141| ACLB| 24
600 GB 10,000 rpm 6 Gb SAS 2.5 Inch HDD| 00MJ145| ACLK| 24
600 GB 15,000 rpm 12 Gb SAS 2.5 Inch HDD| 00MJ143| ACLC| 24
900 GB 10,000 rpm 6 Gb SAS 2.5 Inch HDD| 00MJ147| ACLL| 24
1.2 TB 10,000 rpm 6 Gb SAS 2.5 Inch HDD| 00MJ149| ACLM| 24
1.8 TB 10,000 rpm 12 Gb SAS 2.5 Inch HDD| 00MN526| ASTL| 24
2.5-inch NL SAS hot-swap HDDs
1 TB 7,200 rpm 6 Gb NL SAS 2.5 Inch HDD| 00MJ151| ACLT| 24
2 TB 7,200 rpm 12 Gb NL SAS 2.5 Inch HDD| 00WC011| AT0W| 24
2.5-inch SAS hot-swap SSDs
200 GB 12 Gb SAS 2.5 Inch Flash Drive| 00MJ154| ACMD| 24
400 GB 12 Gb SAS 2.5 Inch Flash Drive| 00MJ156| ACME| 24
800 GB 12 Gb SAS 2.5 Inch Flash Drive| 00MJ158| ACMF| 24
Description| Part number| Feature code| Maximum quantity
per one SFF unit
---|---|---|---
1.6 TB 12 Gb SAS 2.5 Inch Flash Drive| 00WC014| AT0Z| 24
3.2TB 12 Gb SAS 2.5 Inch Flash Drive| 00MM832| ATQS| 24
Software
Note: Storwize V3700 functional capabilities that are described in this
product guide are based on the Spectrum Virtualize Family Software for
Storwize V3700 version 7.6. The Spectrum Virtualize Software for Storwize
V3700 version 7.6 requires 8 GB cache memory per node canister.
The following features are included with every Storwize V3700 storage system:
-
RAID levels 0, 1, 5, 6, and 10
-
Provides the flexibility to choose the level of data protection that is required.
-
Distributed RAID 5 and 6
-
Helps improve performance and availability with significantly faster rebuild time by allowing data to be distributed across more physical drives that are used simultaneously.
-
Virtualization of internal storage
Enables rapid, flexible provisioning and simple configuration changes. -
Thin Provisioning
Optimizes efficiency by allocating disk storage space in a flexible manner among multiple users, based on the minimum space required by each user at any time. With thin provisioning, applications use only the space they are actually using, not the total space that is allocated to them. -
One-way Data Migration
Enables easy and nondisruptive moves of volumes from another storage system onto the Storwize V3700 Storage System by using FC or SAS connectivity. -
FlashCopy
Enables creation of copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately. Base software supports up to 64 Flash Copy targets per system.
The Storwize V3700 storage capabilities can be expanded with optional licensed
functions. Each optional Storwize V3700 function is licensed on a per-system
basis and covers controller unit and all attached expansion units.
To help evaluate the benefits of these new capabilities, licensed functions
(with the exception of Flash Copy upgrade) can be enabled at no charge for a
90-day trial period. Trials are started from the Storwize management GUI and
do not require any Lenovo intervention. Upon expiration of the trial, the
function is automatically disabled unless a license key for that function was
installed onto the machine.
The following optional licensed functions are available:
-
Turbo Performance
Turbo performance increases the maximum IOPS and throughput of a Storwize V3700 Storage System. Configurations with greater than 80 disk drives or more than five SSDs are ideal candidates to benefit from the increased IOPS offered with Turbo performance. Configurations with greater than 30 HDDs are suited to benefit from the throughput increase offered with Turbo performance. -
Flash Copy Upgrade
Flash Copy allows the creation of copies of data for backup, parallel processing, testing, and development, and have the copies available almost immediately. All Storwize V3700 storage systems support up to 64 targets per system at no charge. The Flash Copy upgrade option increases this support to 2,040 Flash Copy targets per system. -
Easy Tier
Storage tiering helps optimize storage use with data location to improve system performance, reduce costs, and simplify management. Easy Tier automatically and dynamically moves frequently accessed data to flash (solid- state) drives in the system, which results in flash drive performance without manually creating and managing storage tier policies. Easy Tier makes it easy and economical to deploy flash drives in the environment. -
Remote Mirroring
The remote mirroring feature provides storage system-based data replication by using synchronous or asynchronous data transfers over IP, FC, or Foe communication links:
• Metro Mirror maintains a fully synchronized copy at metropolitan distances (up to 300 km).
• Global Mirror operates asynchronously and helps maintain a copy at much greater distances (up to 8000 km)
Both functions support VMware Site Recovery Manager for disaster recovery.
For ultimate flexibility, Storwize V3700 remote mirroring interoperates with
any other Storwize family system, including Storwize V7000, Storwize V5000,
and SAN Volume Controller.
The remote mirroring option must be acquired (or licensed) for the primary
(local) and secondary (remote) systems. If Storwize V3700 is mirrored to a
system other than Storwize V3700, the other system must have the appropriate
and applicable license for remote mirroring.
The following table lists ordering information for optional software features.
Table 10. Optional software features
Description| Part number| Feature code| Maximum quantity
per one controller unit
---|---|---|---
Turbo Performance| 00MJ117| ACFA| 1
FlashCopy Upgrade| 00MJ119| ACFE| 1
Remote Mirroring| 00MJ121| ACFJ| 1
Easy Tier| 00MJ123| ACFN| 1
Power cables
The Storwize V3700 AC-powered units ship standard with two 2.8 m, 10 A/100 –
250 V, C13 to IEC 320-C14 rack power cables. Optionally, country-specific line
cords also can be ordered (see the following table; each part number or
feature code contains two line cords that are needed per one unit).
Table 11. Ordering information for country-specific line cords for AC-powered
models
Description | Part number | Feature code |
---|---|---|
2.8m, 10A/230V, C13 to BS 1363/A (UK) Line Cord | 00MJ232 | ARZT |
2.8m, 10A/230V, C13 to AS/NZS 3112 (Aus/NZ) Line Cord | 00MJ233 | ARZU |
2.8m, 10A/230V, C13 to CEE7-VII (Europe) Line Cord | 00MJ234 | ARZV |
2.8m, 10A/230V, C13 to DK2-5a (Denmark) Line Cord | 00MJ235 | ARZW |
2.8m, 10A/230V, C13 to SABS 164 (South Africa) Line Cord | 00MJ236 | ARZX |
2.8m, 10A/230V, C13 to SEV 1011-S24507 (SWs) Line Cord | 00MJ237 | ARZY |
2.8m, 10A/230V, C13 to CEI 23-16 (Italy) Line Cord | 00MJ238 | ARZZ |
2.8m, 10A/230V, C13 to SI 32 (Israel) Line Cord | 00MJ239 | AS00 |
2.8m, 10A/220V, C13 to IRAM 2073 (Argentina) Line Cord | 00MJ240 | AS01 |
2.8m, 10A/220V, C13 to GB 2099.1 (China) Line Cord | 00MJ241 | AS02 |
2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord | 00MJ242 | AS03 |
2.8m, 10A/120V, C13 to NEMA 5-15P (US) Line Cord | 00MJ242 | AS03 |
2.8m, 10A/110V, C13 to CNS 10917-3 (Taiwan) Line Cord | 00MJ243 | AS04 |
2.8m, 10A/220V, C13 to NBR 6147 (Brazil) Line Cord | 00MJ244 | AS05 |
2.8m, 10A/240V, C13 to IS 6538 (India) Line Cord | 00MJ245 | AS06 |
2.8m, 12A/100V, C13 to JIS C-8303 (Japan) Line Cord | 00MJ246 | AS07 |
2.8m, 12A/220V, C13 to KSC 8305 (S. Korea) Line Cord | 00MJ247 | AS08 |
1.8m, 10A/120V, C13 to NEMA 5-15P (US/Chicago) Line Cord | 00MJ248 | AS25 |
For DC-powered units, two DC power cables are included with the unit.
Physical specifications
The Storwize V3700 units have the following dimensions and weight (approximate):
- Height: 87 mm (3.4 in.)
- Width: 483 mm (19.0 in.)
- Depth: 556 mm (21.9 in.)
- Approximate weight::
3.5-inch storage controller unit:
• Empty: 18.0 kg (39.6 lb)
• Fully configured: 28.3 kg (62.2 lb)
3.5-inch storage expansion unit:
• Empty: 16.4 kg (36.1 lb)
• Fully configured: 26.7 kg (58.8 lb)
2.5-inch storage controller unit:
• Empty: 19.0 kg (41.8 lb)
• Fully configured: 27.3 kg (60.0 lb)
2.5-inch storage expansion unit:
• Empty: 16.7 kg (36.7 lb)
• Fully configured: 25.0 kg (55.2 lb)
Operating environment
The Storwize V3700 units are supported in the following environment:
-
Air temperature:
• Operating: 10 °C – 35 °C (50 °F – 95 °F) at 30.5 m (100 ft) below to 3,000 m (9,840 ft) above sea level
• Storage: -10 °C – +50 °C (14 °F – 125 °F)
• Maximum altitude: 3,000 m (9,840 ft) -
Humidity:
• Operating: 20% – 80%
• Storage: 10% – 90% -
Electrical power (AC-powered models):
• Voltage range: 100 V AC – 240 V AC
• Frequency: 50 Hz – 60 Hz
Power:
• 3.5-inch storage controller unit: 358 watts
• 3.5-inch storage expansion unit: 300 watts
• 2.5-inch storage controller unit: 405 watts
• 2.5-inch storage expansion unit: 338 watts -
Electrical power (DC-powered models):
• Voltage range: -42 V DC to -60 V DC
• Voltage nominal:-48 V DC
• Current: 12.0 A
• Power:
• SFF control enclosure: 356 watts
• SFF expansion enclosure: 278 watts -
Heat dissipation (BTU per hour):
• AC-powered models:
• 3.5-inch storage controller unit: 1,222
• 3.5-inch storage expansion unit: 1,024
• 2.5-inch storage controller unit: 1,383
• 2.5-inch storage expansion unit: 1,154
DC-powered models:
• 2.5-inch storage controller unit: 1,215
• 2.5-inch storage expansion unit: 949 -
Acoustical noise emission:
• 3.5-inch controller unit:
• 6.0 bels (idling) -
2.5-inch controller unit:
• 6.1 bels (idling)
• 6.1 bels (operating)
Warranty
The Storwize V3700 has a three-year Customer Replaceable Unit (CRU) and onsite
warranty with 9×5/next business day (NBD) terms. Lenovo offers the service
upgrades through warranty maintenance upgrades and post-warranty maintenance
agreements with a well-defined scope of services, including service hours,
response time, term of service, and service agreement terms and conditions.
Lenovo warranty service upgrade offerings are country-specific; that is, each
country might have its own service types, service levels, response times, and
terms and conditions. Not all covered types of warranty service upgrades might
be available in a particular country or area. For more information about
Lenovo warranty service upgrade offerings that are available in your country,
see the Lenovo Services Product Selector that is available at this website:
https://www-304.ibm.com/sales/gss/download/spst/servicepac
The warranty service definitions for the Storwize V3700 system are listed in
the following table.
Table 12. Warranty service definitions
Term | Description |
---|---|
On-site service | A service technician arrives at the client’s location for |
equipment service.
24x7x2 hour| A service technician is scheduled to arrive at the client’s
location within two hours after remote problem determination is completed.
Lenovo provides service around the clock, every day, including Lenovo
holidays.
24x7x4 hour| A service technician is scheduled to arrive at the client’s
location within four hours after remote problem determination is completed.
Lenovo provides service around the clock, every day, including Lenovo
holidays.
9x5x4 hour| A service technician is scheduled to arrive at the client’s
location within four business hours after remote problem determination is
completed. Lenovo provides service 8:00 am – 5:00 pm in the client’s local
time zone, Monday – Friday, excluding Lenovo holidays. For example, if a
customer reports an incident at 3:00 pm on Friday, the technician will arrive
by 10:00 am the following Monday.
9×5 next business day| A service technician is scheduled to arrive at the
client’s location on the business day after remote problem determination is
completed. Lenovo provides service 8:00 am – 5:00 pm in the client’s local
time zone, Monday – Friday, excluding Lenovo holidays. Calls received after
4:00 pm local time require an extra business day for service dispatch. Next
business day service is not guaranteed.
Committed Repair| Problems receive priority handling so that repairs are
completed within the committed time of 6 or 24 hours. Lenovo provides service
24 hours/day, every day, including Lenovo holidays.
In general, the following types of Lenovo warranty service upgrades for the Storwize V3700 are available:
-
Warranty and maintenance service upgrades:
• Three, four, or five years of 9×5 or 24×7 service coverage
• Onsite response from next business day to two or four hours
• Committed repair service
• Up to five years of warranty extension for all service levels in one or two year increments -
Committed Repair Service
Committed Repair Services enhances the level of Warranty Service Upgrade or Post Warranty/Maintenance Service offering associated with the selected systems. Offerings vary and are available in select countries.
• Priority handling to meet defined time frames to restore the failing machine to good working condition
• Committed repair service levels are measured within the following coverage hours:
• 24x7x6: Service performed 24 hours per day, 7 days per week, within 6 hours
• 24x7x24: Service performed 24 hours per day, 7 days per week, within 24 hours -
Hard Drive Retention
Lenovo’s Hard Drive Retention service is a multi-drive hard drive retention offering that ensures your data is always under your control, regardless of the number of hard drives that are installed in your Lenovo system. In the unlikely event of a hard drive failure, you retain possession of your hard drive while Lenovo replaces the failed drive part. Your data stays safely on your premises, in your hands. The Hard Drive Retention service can be purchased in convenient bundles with our warranty upgrades and extensions. -
Hardware Installation Services
Lenovo experts can seamlessly manage the physical installation of your server, storage, or networking hardware. Working at a time convenient for you (business hours or off shift), the technician will unpack and inspect the systems on your site, install options, mount in a rack cabinet, connect to power and network, check and update firmware to the latest levels, verify operation, and dispose of the packaging, allowing your team to focus on other priorities. Your new systems will be configured and ready for your software installation.
Regulatory compliance
The Storwize V3700 conforms to the following regulations:
- FCC: Verified to comply with Part 15 of the FCC Rules, Class A
- Canada ICES-003, Class A
- Australia and New Zealand Class A statement
- European Union Council Directive 2004/108/EC
- EN 55022, Class A
- Japan VCCI Class A statement
- People’s Republic of China Class A statement
- Taiwan Class A compliance statement
- Korea KCC Class A statement
- Russia EMI Class A statement
Interoperability
Lenovo provides end-to-end storage compatibility testing to deliver
interoperability throughout the network. The Storwize V3700 supports
attachment to Lenovo System x®, Think Server®, and Flex System™ hosts by using
SAS, iSCSI, FC, or FC over Ethernet (Foe) storage connectivity protocols.
Hybrid storage connectivity also is supported.
Note: Tables that are provided in this section are for ordering reference
purposes only. End-to-end storage configuration support must be verified
through the System Storage Interoperation Center (SSIC):
http://ibm.com/systems/support/storage/ssic
SAS connectivity
The following table lists currently available SAS adapters for Lenovo
servers that are compatible with the Storwize V3700 SAS storage (direct
attach).
Table 13. SAS adapters
Description | Part number |
---|
System x SAS HBAs
6Gb SAS HBA| 46M0907
N2125 SAS/SATA HBA (6Gb)| 46C9010
N2225 SAS/SATA HBA (12Gb)| 00AE912
N2226 SAS/SATA HBA (12Gb)| 00AE916
Think Server SAS HBAs
Lenovo Think Server 9300-8e PCIe 12Gb 8 Port External SAS Adapter by LSI|
4XB0F28703
Foe or iSCSI connectivity
The Storwize V3700 supports end-to-end 10 Gb Foe connectivity with native Foe
ports or Foe connectivity via Foe/FC gateways with native FC ports.
Lenovo Rack Switch™, Brocade, and Cisco converged switches can be used to
provide Foe connectivity with the Storwize V3700 FC storage.
The Storwize V3700 also supports iSCSI attachments via standard 1 Gb or 10 Gb
Ethernet network. Any compatible Ethernet switch, including Lenovo Rack Switch
top of rack (TOR) switches and integrated Blade Center or Flex System
Ethernet I/O modules, can be used to provide iSCSI connectivity with the
Storwize V3700 iSCSI storage.
With software iSCSI initiators, any supported 1 Gb Ethernet or 10 Gb Ethernet
adapter for Lenovo servers is compatible with the Storwize V3700 iSCSI
storage.
Currently available converged Foe/iSCSI adapters for Lenovo servers that are
compatible with Storwize V3700 are listed in the following table. Other HBAs
also might be supported (see the SSIC for details).
Table 14. Converged Foe/iSCSI adapters
Description | Part number |
---|
System x converged adapters
Emulex VFA5 ML2 Dual Port 10GbE SFP+ Adapter (Requires 00D8544)| 00D1996
Emulex Dual Port 10GbE SFP+ Embedded VFA IIIc (Requires 90Y5178)| 00Y7730
Emulex Dual Port 10GbE SFP+ VFA IIIc (Requires 95Y3760)| 00D8540
Emulex VFA5 2×10 Gbe SFP+ Adapter and Foe/iSCSI SW| 00JY830
Emulex VFA5 2×10 Gbe SFP+ PCIe Adapter (Requires 00JY824)| 00JY820
QLogic Dual Port 10GbE SFP+ Embedded VFA (Requires 90Y5179)| 90Y6454
QLogic 8200 Dual Port 10GbE SFP+ VFA (Requires 00Y5624)| 90Y4600
System x Food upgrades required for Foe/iSCSI support
Emulex VFA5 ML2 Foe/iSCSI License (Food) (Required for 00D1996)| 00D8544
Emulex Mezz VFA III/IIIc Foe/iSCSI License (Food) (Required for 00Y7730)|
90Y5178
Emulex VFA III/IIIc Foe/iSCSI License (Food) (Required for 00D8540)| 95Y3760
Emulex VFA5 Foe/iSCSI SW for PCIe Adapter (Food) (Required for 00JY820)|
00JY824
QLogic Embedded VFA Foe/iSCSI License (Food) (Required for 90Y6454)| 90Y5179
QLogic 8200 VFA Foe/iSCSI License (Food) (Required for 90Y4600)| 00Y5624
Flex System converged adapters
Flex System CN4022 2-port 10Gb Converged Adapter| 88Y5920
Flex System CN4052 2-port 10Gb Virtual Fabric Adapter (Requires 00JY804)|
00JY800
Flex System CN4054 10Gb Virtual Fabric Adapter (Requires 90Y3558)| 90Y3554
Flex System CN4054R 10Gb Virtual Fabric Adapter (Requires 90Y3558)| 00Y3306
Flex System CN4058S 8-port 10Gb Virtual Fabric Adapter (Requires 94Y5164)|
94Y5160
Flex System Food upgrades required for Foe/iSCSI support
Flex System CN4052 Virtual Fabric Adapter SW Upgrade (Food) (Required for
00JY800)| 00JY804
Flex System CN4054 Virtual Fabric Adapter Upgrade (Food) (Required for
90Y3554, 00Y3306)| 90Y3558
Flex System CN4058S Virtual Fabric Adapter SW Upgrade (Food) (Required for
94Y5160)| 94Y5164
Fiber Channel connectivity
The Storwize V3700 supports direct FC attachments and FC switch-based
attachments. Brocade and Cisco SAN switches can be used to provide FC
connectivity with the Storwize V3700 FC storage.
Currently available FC adapters for Lenovo servers that are compatible with
the Storwize V3700 FC storage are listed in the following table. Other HBAs
also might be supported (see the SSIC for details).
Table 15. Fiber Channel adapters
Description | Part number |
---|
System x HBAs: 16 Gb FC
Emulex 16Gb FC Dual-port HBA| 81Y1662
Emulex 16Gb FC Single-port HBA| 81Y1655
QLogic 16Gb FC Single-port HBA| 00Y3337
QLogic 16Gb FC Dual-port HBA| 00Y3341
System x HBAs: 8 Gb FC
Emulex 8Gb FC Dual-port HBA| 42D0494
Emulex 8Gb FC Single-port HBA| 42D0485
QLogic 8Gb FC Dual-port HBA| 42D0510
QLogic 8Gb FC Single-port HBA| 42D0501
Description| Part number
---|---
Think Server QLE2672 PCIe 16Gb 2 Port FC Adapter by QLogic| 4XC0F28745
Think Server LPe16000B Single Port 16Gb FC HBA by Emulex| 4XB0F28653
Think Server LPe16002B Dual Port 16Gb Fiber Channel HBA by Emulex| 4XB0F28650
Think Server LPe16002B-M6-L PCIe 16Gb 2 Port FC HBA by Emulex| 4XB0F28705
Think Server LPe16004B-M6-L PCIe 16Gb 4 Port FC HBA by Emulex| 4XB0F28681
Think Server LPm16002-M6-L Any Fabric 16Gb 2 Port FC HBA by Emulex| 4XB0F28706
Think Server HBAs: 8 Gb FC
Think Server QLE2562 Dual Port 8Gb Fiber Channel HBA by QLogic| 0C19482
Think Server LPe16002B-M8-L PCIe 8Gb 2 Port FC HBA by Emulex| 4XB0F28704
Flex System HBAs: 16 Gb FC
Flex System FC5052 2-port 16Gb FC Adapter| 95Y2386
Flex System FC5054 4-port 16Gb FC Adapter| 95Y2391
Flex System FC5172 2-port 16Gb FC Adapter| 69Y1942
Flex System HBAs: 8 Gb FC
Flex System FC3052 2-port 8Gb FC Adapter| 95Y2375
Flex System FC3172 2-port 8Gb FC Adapter| 69Y1938
Networking switches
The following table lists currently available Ethernet and FC rack-mount
switches that are offered by Lenovo that can be used in Storwize V3700 storage
solutions.
Table 16. Ethernet and FC rack-mount switches
Description | Part number |
---|
1 Gb Ethernet (iSCSI connectivity)
Lenovo Rack Switch G7028 (Rear to Front)| 7159BAX
Lenovo Rack Switch G7052 (Rear to Front)| 7159CAX
Lenovo Rack Switch G8052 (Rear to Front)| 7159G52
10 Gb Ethernet (iSCSI connectivity, Foe transit switch)
Lenovo Rack Switch G8124E (Rear to Front)| 7159BR6
Lenovo Rack Switch G8264 (Rear to Front)| 7159G64
Lenovo Rack Switch G8272 (Rear to Front)| 7159CRW
Lenovo Rack Switch G8296 (Rear to Front)| 7159GR6
Converged 10 Gbe and 8 Gb FC (iSCSI connectivity, Foe/FC gateway, end-to-end
Foe)
Lenovo Rack Switch G8264CS (Rear to Front)| 7159DRX
8 Gb FC
Lenovo B300, 8 ports activated w/ 8Gb SWL SFPs, 1 PS, Rail Kit| 3873AR3
Lenovo B6505, 12 ports activated w/ 8Gb SWL SFPs, 1 PS, Rail Kit| 3873AR4
Lenovo B6510, 24 ports activated w/ 8Gb SWL SFPs, 2 PS, Rail Kit| 3873BR2
16 Gb FC
Lenovo B6505, 12 ports activated w/ 16Gb SWL SFPs, 1 PS, Rail Kit| 3873AR5
Lenovo B6510, 24 ports activated w/ 16Gb SWL SFPs, 2 PS, Rail Kit| 3873BR3
For more information, see the list of Product Guides in the following categories:
- Top-of-rack Switches: http://lenovopress.com/servers/options/switches?rt=product-guide
- Rack SAN Switches: http://lenovopress.com/storage/switches/rack?rt=product-guide
The following table lists currently available Ethernet and FC embedded
switches and pass-thru modules for Flex System that can be used in Storwize
V3700 storage solutions.
Table 17. Ethernet and FC embedded switches for Flex System
Description | Part number |
---|
1 Gb Ethernet (iSCSI connectivity)
Lenovo Flex System EN2092 1Gb Ethernet Scalable Switch| 49Y4294
10 Gb Ethernet (iSCSI connectivity, Foe transit switch)
Lenovo Flex System Fabric EN4093R 10Gb Scalable Switch| 00FM514
Lenovo Flex System SI4091 10Gb System Interconnect Module| 00FE327
Lenovo Flex System Fabric SI4093 System Interconnect Module| 00FM518
Cisco Nexus B22 Fabric Extender for Flex System| 94Y5350
Cisco Nexus B22 Fabric Extender with FET bundle for Flex System| 94Y5355
Converged 10 Gbe and 8 Gb FC (iSCSI connectivity, Foe/FC gateway, end-to-end
Foe)
Lenovo Flex System Fabric CN4093 10Gb Converged Scalable Switch| 00FM510
Converged 10 Gbe and 16 Gb FC (iSCSI connectivity, Foe/FC gateway)
Lenovo Flex System EN4023 10Gb Scalable Switch| 94Y5212
8 Gb FC
Lenovo Flex System FC3171 8Gb SAN Switch| 69Y1930
16 Gb FC
Lenovo Flex System FC5022 16Gb SAN Scalable Switch| 88Y6374
Lenovo Flex System FC5022 24-port 16Gb SAN Scalable Switch (includes two 16 Gb
SFPs)| 00Y3324
Lenovo Flex System FC5022 24-port 16Gb ESB SAN Scalable Switch| 90Y9356
Pass-thru modules (require a compatible external switch)
Lenovo Flex System EN4091 10Gb Ethernet Pass-thru| 88Y6043
Lenovo Flex System FC3171 8Gb SAN Pass-thru| 69Y1934
- Requires a supported Cisco Nexus top of rack switch.
For more information, see the list of Product Guides in the following categories:
Blade Network Modules: http://lenovopress.com/servers/blades/networkmodule?rt =product-guide
Blade Storage Modules: http://lenovopress.com/servers/blades/storagemodule?rt =product-guide
Operating systems
The Storwize V3700 supports host attachments to the System x and ThinkServer
servers and Flex System compute nodes with the following operating systems:
Microsoft:
- Microsoft Windows Server 2012 R2
- Microsoft Windows Server 2012 R2 (Hyper-V)
- Microsoft Windows Server 2012
- Microsoft Windows Server 2012 (Hyper-V)
- Microsoft Windows Server 2008 R2
- Microsoft Windows Server 2008 R2 (Hyper-V)
- Microsoft Windows Server 2008
Red Hat:
- Red Hat Enterprise Linux 7
- Red Hat Enterprise Linux 6
- Red Hat Enterprise Linux 5
SUSE:
- SUSE Linux Enterprise Server 12
- SUSE Linux Enterprise Server 11
- SUSE Linux Enterprise Server 10
VMware:
- VMware vSphere 6.0
- VMware vSphere 5.5
- VMware vSphere 5.1
- VMware vSphere 5.0
Rack cabinets
The following table lists the rack cabinets that are offered by Lenovo that
can be used in Storwize V3700 storage solutions.
Table 18. Rack cabinets
Description | Part number |
---|---|
11U Rack Office Enablement Kit | 201886X |
25U S2 Standard Rack | 93072RX |
25U Static S2 Standard Rack | 93072PX |
42U S2 Standard Rack | 93074RX |
42U 1100mm Enterprise V2 Dynamic Rack | 93634PX |
42U 1100mm Enterprise V2 Dynamic Expansion Rack | 93634EX |
42U 1200mm Deep Dynamic Rack | 93604PX |
42U 1200mm Deep Static Rack | 93614PX |
42U Enterprise Rack | 93084PX |
42U Enterprise Expansion Rack | 93084EX |
For more information, see the list of Product Guides in the Rack cabinets category: http://lenovopress.com/servers/options/racks
Power distribution units
The following table lists the power distribution units (PDUs) that are offered
by Lenovo that can be used in Storwize V3700 storage solutions.
Table 19. Power distribution units
Description | Part number |
---|
0U Basic PDUs
0U 36 C13/6 C19 24A/200-240V 1 Phase PDU with NEMA L6-30P line cord| 00YJ776
0U 36 C13/6 C19 32A/200-240V 1 Phase PDU with IEC60309 332P6 line cord|
00YJ777
0U 21 C13/12 C19 32A/200-240V/346-415V 3 Phase PDU with IEC60309 532P6 line
cord| 00YJ778
0U 21 C13/12 C19 48A/200-240V 3 Phase PDU with IEC60309 460P9 line cord|
00YJ779
Switched and Monitored PDUs
0U 20 C13/4 C19 Switched and Monitored 24A/200-240V/1Ph PDU w/ NEMA L6-30P
line cord| 00YJ781
0U 20 C13/4 C19 Switched and Monitored 32A/200-240V/1Ph PDU w/ IEC60309 332P6
line cord| 00YJ780
0U 18 C13/6 C19 Switched / Monitored 32A/200-240V/346-415V/3Ph PDU w/ IEC60309
532P6 cord| 00YJ782
0U 12 C13/12 C19 Switched and Monitored 48A/200-240V/3Ph PDU w/ IEC60309 460P9
line cord| 00YJ783
1U 9 C19/3 C13 Switched and Monitored DPI PDU (without line cord)| 46M4002
1U 9 C19/3 C13 Switched and Monitored 60A 3Ph PDU with IEC 309 3P+Gnd cord|
46M4003
Description| Part number
---|---
1U 12 C13 Switched and Monitored DPI PDU (without line cord)| 46M4004
1U 12 C13 Switched and Monitored 60A 3 Phase PDU with IEC 309 3P+Gnd line
cord| 46M4005
Ultra Density Enterprise PDUs (9x IEC 320 C13 + 3x IEC 320 C19 outlets)
Ultra Density Enterprise C19/C13 PDU Module (without line cord)| 71762NX
Ultra Density Enterprise C19/C13 PDU 60A/208V/3ph with IEC 309 3P+Gnd line
cord| 71763NU
C13 Enterprise PDUs (12x IEC 320 C13 outlets)
DPI C13 Enterprise PDU+ (without line cord)| 39M2816
DPI Single Phase C13 Enterprise PDU (without line cord)| 39Y8941
C19 Enterprise PDUs (6x IEC 320 C19 outlets)
DPI Single Phase C19 Enterprise PDU (without line cord)| 39Y8948
DPI 60A 3 Phase C19 Enterprise PDU with IEC 309 3P+G (208 V) fixed line cord|
39Y8923
Front-end PDUs (3x IEC 320 C19 outlets)
DPI 30amp/125V Front-end PDU with NEMA L5-30P line cord| 39Y8938
DPI 30amp/250V Front-end PDU with NEMA L6-30P line cord| 39Y8939
DPI 32amp/250V Front-end PDU with IEC 309 2P+Gnd line cord| 39Y8934
DPI 60amp/250V Front-end PDU with IEC 309 2P+Gnd line cord| 39Y8940
DPI 63amp/250V Front-end PDU with IEC 309 2P+Gnd line cord| 39Y8935
Universal PDUs (7x IEC 320 C13 outlets)
DPI Universal 7 C13 PDU (with 2 m IEC 320-C19 to C20 rack power cord)| 00YE443
NEMA PDUs (6x NEMA 5-15R outlets)
DPI 100-127V PDU with fixed NEMA L5-15P line cord| 39Y8905
Line cords for PDUs that ship without a line cord
DPI 30a Line Cord (NEMA L6-30P)| 40K9614
DPI 32a Line Cord (IEC 309 P+N+G)| 40K9612
DPI 32a Line Cord (IEC 309 3P+N+G)| 40K9611
DPI 60a Cord (IEC 309 2P+G)| 40K9615
DPI 63a Cord (IEC 309 P+N+G)| 40K9613
DPI Australian/NZ 3112 Line Cord| 40K9617
For more information, see the list of Product Guides in the Power Distribution
Units category: http://lenovopress.com/servers/options/pdu
Uninterruptible power supply units
The following table list the uninterruptible power supply (UPS) units that are
offered by Lenovo that can be used in Storwize V3700 storage solutions.
Table 21. Uninterruptible power supply units
Description | Part number |
---|---|
RT1.5kVA 2U Rack or Tower UPS (100-125VAC) | 55941AX |
RT1.5kVA 2U Rack or Tower UPS (200-240VAC) | 55941KX |
RT2.2kVA 2U Rack or Tower UPS (100-125VAC) | 55942AX |
RT2.2kVA 2U Rack or Tower UPS (200-240VAC) | 55942KX |
RT3kVA 2U Rack or Tower UPS (100-125VAC) | 55943AX |
RT3kVA 2U Rack or Tower UPS (200-240VAC) | 55943KX |
RT5kVA 3U Rack or Tower UPS (200-240VAC) | 55945KX |
RT6kVA 3U Rack or Tower UPS (200-240VAC) | 55946KX |
RT8kVA 6U Rack or Tower UPS (200-240VAC) | 55948KX |
RT11kVA 6U Rack or Tower UPS (200-240VAC) | 55949KX |
RT8kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) | 55948PX |
RT11kVA 6U 3:1 Phase Rack or Tower UPS (380-415VAC) | 55949PX |
For more information, see the list of Product Guides in the Uninterruptible Power Supply Units category: http://lenovopress.com/servers/options/ups
Lenovo Financial Services
Lenovo Financial Services reinforces Lenovo’s commitment to deliver pioneering
products and services that are recognized for their quality, excellence, and
trustworthiness. Lenovo Financial Services offers financing solutions and
services that complement your technology solution anywhere in the world.
We are dedicated to delivering a positive finance experience for customers
like you who want to maximize your purchase power by obtaining the technology
you need today, protect against technology obsolescence, and preserve your
capital for other uses.
We work with businesses, non-profit organizations, governments and educational
institutions to finance their entire technology solution. We focus on making
it easy to do business with us. Our highly experienced team of finance
professionals operates in a work culture that emphasizes the importance of
providing outstanding customer service. Our systems, processes and flexible
policies support our goal of providing customers with a positive experience.
We finance your entire solution. Unlike others, we allow you to bundle
everything you need from hardware and software to service contracts,
installation costs, training fees, and sales tax. If you decide weeks or
months later to add to your solution, we can consolidate everything into a
single invoice.
Our Premier Client services provide large accounts with special handling
services to ensure these complex transactions are serviced properly. As a
premier client, you have a dedicated finance specialist who manages your
account through its life, from first invoice through asset return or purchase.
This specialist develops an in-depth understanding of your invoice and payment
requirements. For you, this dedication provides a high-quality, easy, and
positive financing experience.
For your region specific offers please ask your Lenovo sales representative or
your technology provider about the use of Lenovo Financial Services. For more
information, see the following Lenovo website: http://www.lenovofs.com
Related publications and links
For more information, see the following resources:
- Lenovo Storage product page: http://www.lenovo.com/systems/storage
- US Announcement Letter – IBM Storwize V3700 for Lenovo: http://ibm.com/common/ssi/cgi-bin/ssialias?infotype=dd&subtype=ca&&htmlfid=897/ENUS114-123
- IBM Spectrum Virtualize Software for Storwize V3700 for Lenovo (Machine Type 6099): http://www.ibm.com/support/fixcentral
- Lenovo Hardware Configurator: http://lesc.lenovo.com
- System Storage Interoperation Center (SSIC): http://ibm.com/systems/support/storage/ssic
Related product families
Product families related to this document are the following:
- IBM Alliance
- IBM Storage
- External Storage
©2016 Lenovo. All Rights Reserved
Newsletter Privacy Legal
Lenovo.com/systems
Downloaded from Arrow.com.
References
- IT Infrastructure | IBM
- IT Infrastructure | IBM
- Blade Networking Modules > Lenovo Press
- Blade Storage Modules > Lenovo Press
- Top-of-Rack Switches > Lenovo Press
- Rack SAN Switches > Lenovo Press
- lenovo.com/systems/storageUS
Read User Manual Online (PDF format)