Energizer PPS2000 Solar Generator User Manual
- June 12, 2024
- Energizer
Table of Contents
Energizer PPS2000 Solar Generator
Energizer. PPS2000W01 Portable Power Station
No more worries about being outdoors or having a power outage. With 2150Wh
capacity and up to 21 OOW AC output, PPS2000W01 always keeps you charged at
any on-the-go moment. Featuring 100W USB-C PD, 2100W AC power outlet and USB-A
charging ports, PPS2000W01 provides 17 outputs that can charge multiple
devices or appliances simultaneously and efficiently. With premium battery and
PowerSafe management. Energizer Portable Power Station PPS2000W01 is your
most reliable and safe power solution anytime, anywhere.
ATTENTION
- The specifications and the pictures in this manual are for reference only.
- The product is perfect for off-grid power needs or backup power for emergency situations.
- Actual AC outlet and AC adapter will be different depending on the locations of the customer.
- To maximize the battery life, please fully charge the product before using ii for the first lime.
Get To Know Your Product
QuickGuide
- Aviation Output
- Power Button
- LCD Touch Screen
- AC Outputx6
- Aviation Input
- AC Adapter Input
- Wireless Charging
- USB-A Output
- USB-A 18W
- 12V DC Charging Port
- DC 5521 Output
- Output PD100W
Charging Your Product
ATTENTION
If the ambient temperature is too high or the battery temperature is higher
than 60 °C due to continuous high-power discharge, the product cannot be
charged. When the battery temperature is less than 55 °C, the charging
function will automatically resume. If the battery is not used for a long
time, the battery should be stored in a dry and ventilated room with an
ambient temperature of 0-35 °C for more than 3 months, and the battery should
be charged to 50%-80%.
LCD Battery Display
As you use your product, segments will disappear from the display, indicating the remaining charge. When charging your product you will notice a battery segment blinking at a 1-second interval status. Once your product is fully charged, all battery segments will be lit and remain solid.
Charge Through Solar Panel
- Place your solar panel where it will get as much strong direct sunlight as possible.
- Connect the output port of the solar panel with the input port of the product to start charging. You will know the product is being charged when the LCD displays the charging percentages on the screen. The product is fully charged when displays 100%.
Notes:
The actual charging efficiency can vary widely depending on weather, ambient
temperature, sunlight, and the angle that the solar panel faces to direct
sunlight and other factors. The maximum output voltage of the solar panel
should not exceed 145V.
In order to ensure solar charging efficiency, it is recommended to use solar panels with an open circuit voltage of 10-145V. The maximum current can reach 15A.
Charge Through AC Adapter
Plug the adapter (optional) into its DC input port and you will see the state of charge displayed on the screen.
Notes:
- The product is fully charged when the battery displays 100% capacity on the screen. After the product is fully charged, please unplug the AC wall charger as soon as possible.
- Usually, it takes about 5 hours to fully charge the machine using the original power adapter.
Charge Through Your Car
- Plug the car charger into the 12 V DC Charging Port of your car, and then plug into the DC input port of the machine.
- The original car charger features a 1 DA protector tube to protect your car.
- The product is fully charged when the battery displays 100% capacity on the screen.
Charge Through Lead-Acid Battery
- Take proper precautions whenever handling a Lead-acid battery. Wear protective eyeglasses and gloves to protect yourself from any acid that may leak from the battery.
- Connect the charger’s red positive ( +) cable clamp to the positive ( +) post.
- Secure the black negative(-) cable clamp to the negative(-) post.
- Plug the charger into the Aviation input socket.
Notes:
To avoid car battery power loss, you should charge this product through your
12V DC Charging Port only when your car engine is started. This function is
for 12V cars ONLY.
Protection mode (DC input)
- Due to the different models of cars, they may not be fully charged.
- Under-voltage protection: The power generator can’t be charged if the voltage of your car is too low.
AC+DC Dual Charging
Plug your AC and DC charger to speed up charging.
Using Your Product
Buttons & Switches
-
a. PV / Other Charging Display
-
b. BMS Info
-
c. Date/Time
-
d. DC Load Info
-
e. DC ON/ OFF Switch
-
f. AC ON/ OFF Switch
-
g. Adapter Charging Display
-
h. AC Load Info
-
Press the power button to turn the machine on. Press again to turn the machine off.
-
Tap the switch on the screen in the homepage to turn your output mode ON/ OF F.
USB Output Function
When two USB-A 5V/3A ports are used simultaneously, the two ports can only output 5V/3A total, so they cannot enter the fast charging mode.
DC Outputs
- The 12V DC Charging Port and The DC5521 (5.5mm in diameter) 11.2-14.6V ports offer a max 1 DA output current and automatically distribute max current according to the externally connected devices to ensure the shortest charging time.
- The DC5521 port can be connected with a 12V DC Charging Port (power requires no more than 120 w).
Notes:
If the output DC and USB of the product are greater than 32A at the same lime,
the buzzer alarms after the product runs for three minutes. The LCD error code
is E11. If the alarm lasts for 30 seconds and is not cleared, the product will
forcibly shut down the DC output to reduce the total DC output current and
ensure the safety of the product.
In vehicle charging mode, when the voltage of the charging port is lower than 11.2V, the charging function will stop charging to avoid over-discharge of vehicle power.
Protection mode (DC outputs)
Short circuit protection: when short-circuit occurs to the external devices,
the machine starts beeping and stops charging.
Product Specifications
Battery
Battery | LiFeP04 Battery |
---|---|
Battery Capacity | 2150Wh, 51.2VDC, 42000mah |
Lifecycles | 2000 Cycles to 80% Capacity |
Battery Maintenance | Charge Every 3-6 Months |
Port (Output)
USB-Ax2 | 5V DC, 3A 15W total |
---|---|
QC3.0USBx2 | 5V DC, 3A; 9V DC 2A; 12V DC, 1.5A |
PD Type-C Port | 5/9/12/15V DC, 3A; 20V DC, SA |
DC 5521>2 | 12V, 1OA total |
Car Charging
RV/ Aviations Sockets| 12V, 30A
Wireless Charging x2| 5l7.5/10V DC, 15Wx2
AC Output x6| 100V AC, 2000W total; 110V AC, 2100W total
Charging (Input)
Solar Charging | 10-145V DC, 15A, 900W Max |
---|---|
Car Charging | 11-28.8V, 8.2A |
Battery Charging
General
Weight | About 66.1 lbs/ 30 kg |
---|---|
Dimensions | 17.3×11.6×15.3 in |
Discharge Temp | -4-104’F (-20-40°() |
Charge Temp | 32-104’F (0-40′() |
Cold Weather Usage
Cold temperatures can affect the product’s battery capacity due to the
chemical characteristics of the battery. If you’ll be living off the grid in
sub-zero conditions, it is recommended to keep your product in an insulated
cooler, and connected to a power source (12V car/AC adapter/solar panel). The
natural heat generated by the product contained in an insulated cooler will
keep battery capacity at its highest level.
Disposal And Recycle
This product should not be disposed of along with household waste. Please
dispose of or recycle this product and the battery inside according to the
local rules and regulations.
Battery Information
This product has an internal, non-removable, LiFeP04 Rechargeable battery. Do
not attempt to remove the battery, as you may damage the device.
Error Code
Code | Causes | Solutions |
---|---|---|
001 | PV Over Voltage | Please check if the open circuit voltage of solar panels |
exceeds the input voltage standard of the power station.
004| DC Output Short Circuit| Please disconnect the appliances on DC output
ports.
005| Adapter Over Voltage| Please check that the adapter output voltage meets
the specification. Clear the alarm history or restart the unit.
006| Adapter Low Voltage| Please check that the adapter output voltage meets
the specification. Clear the alarm history or restart the unit.
007| Adapter Relay Error| Clear the alarm history or restart the unit.
008| Adapter Over Current| Please check that the adapter output voltage meets
the specification. Clear the alarm history or restart the unit.
010| USB/TYPE-COver Current| Please disconnect the appliances on USS ports.
Clear the alarm history or restart the unit.
011| 12V/l OA Over Current| Please disconnect the appliances on DC 12V/10A
ports. Clear the alarm history or restart the unit.
012| 12V/30A Over Current| Please disconnect the appliances on DC 12V/30A
ports. Clear the alarm history or restart the unit.
014| DC Start Failure| Clear the alarm history or restart the unit.
015| DCOutput Relay Error| Cleilr the alarm history or restilrt the unit.
016| BusStart Failure| Clear the alarm history or restart the unit.
017| Inverter Start Failure| Turn on the AC after rebooting, please contact
the dealer if the error still exists.
018| Bus Low Voltage| Turn on the AC after rebooting, please contact the
dealer if the error still exists.
019| BusHigh Voltage| Turn on the AC after rebooting, please contact the
dealer if the error still exists.
020| Inverter Low Voltage| Please check if the output of the load meets the
specifications of the unit. Turn on the AC after rebooting, please contact the
dealer if the error still exists.
021| Inverter High Voltage
022| Inverter Low Frequency| Please check if the output of the load meets the
specifications of the unit. Turn on the AC after rebooting, please contact the
dealer if the error still exists.
023| Inverter High Frequency
025| Battery High Voltage| Please contact the dealer if the error still exists
after rebooting the unit.
026| Battery Low Voltage| Please contact the dealer if the error still exists
after rebooting the unit.
---|---|---
027| Battery Unconnected
028| Fan Error| Clean or replace the fan to ensure proper ventilation. Please
contact the dealer if the error still exists after rebooting the unit.
029| NTCError| Leave the unit at the recommended temperature few hours to
recover. Please contact the dealer if the error still exists after rebooting
the unit.
030| Calibration Error| Please contact the dealer if the error still exists
after rebooting the unit.
031| Inverter Over Load| Please disconnect the load to make sure the output
power of the loads meets the limit of the unit. Click to clear the alarm
history.
032| Inverter Short Circuit| Please disconnect the load to make sure the load
has been connected properly. Click to clear the alarm history.
033| DSPCommunication Error| Please contact the dealer if the error still
exists after rebooting the unit.
034| BMSCommunication Error| Please contact the dealer if the error still
exists after rebooting the unit.
035| EEPROM Read_write Error| Please contact the dealer if the error still
exists after rebooting the unit.
036| Parameters of Control Module Error| Reset the configurations on
“Settings#. Please contact the
dealer If the power station has not been recovered after rebooting.
041| BMSTemperature Error| Please store the power station at the recommended
temperature and leave it until the temperature inside is back to the normal standard.
042| BMSOver Voltage| Please contact the dealer if the error still exists
after rebooting the unit.
043| BMS Low Voltage| Please contact the dealer if the error still exists
after rebooting the unit.
044| BMSOver Current| Please contact the dealer if the error still exists
after rebooting the unit.
045| BMSPre-charge Failure| Please contact the dealer if the error still
exists after rebooting the unit.
046| BMSOutput Short Circuit| Please contact the dealer if the error still
exists after rebooting the unit.
051| AC Output Locked| Disconnect the load to make sure the output power of
the loads meets the limit of the unit. Please contact the dealer if the error
still exists after rebooting the unit.
053| USB/TYPE-C/PDLocked
054| l 2Vl OA Locked| Disconnect the load to make sure the output power of the
lauds meet the limit of the unit. Please contact the dealer if the error still
exists after rebooting the unit.
055| l 2V30ALocked
Frequently Asked Questions
-
Q1: The temperature of the adapter is getting high when I charge it, is that alright?
A: It’s totally normal for the adapter to get warm, because of the heat produced in the circuit during charging. -
Q2: Why did the unit automatically shut down with my appliance connected?
A: The “ECO MODE” {default) is set to shut down the unit when the AC output of the unit is lower than 50W in 4 hours for power saving. -
Q3: What causes the cooling fan not to launch?
A: With the excellent heat dissipation design, the cooling fan will only launch when the total loads exceed 30% of the rated output. -
Q4: Can I charge and discharge the power station simultaneously?
A: Yes, it is supported, but not recommended in order to protect the lifespan of the battery. -
Q5: How to claim the warranty?
A: Please refer to the warranty card or the official website for further warranty policy.
Abbreviation Explain
- DC/AC= Direct Current/Alternating Current
- BMS = Battery Management System
- PV = Photovoltaic (Solar Power)
- CS = Charging State
AC Output
- Plug the power cable of the AC appliance into the AC outlet of the machine. Press the power button to enter AC mode.
- Make sure the power of the connected AC applianced is less than 100v 2000w, 110V/120V 2100W.
Notes:
- In the case of no operation, the LCD backlight will turn off after 1 minute as default.
- This time can be adjusted through the screen to 30 seconds, 1 minute, 5 minutes, and steady on. When the machine is in the standby state, it will automatically shut down for 24 hours.
- In ECO mode, the AC output is automatically turned off 4 hours after the AC output is unloaded. When the AC power is not in use, please turn off the AC power.
Protection mode: (AC output)
- This product has under-voltage protection, overload protection, and short-circuit protection. The overtemperature protection is a double-insulated circuit that is safe, reliable, and efficient.
- When overload, overtemperature, or short circuit occurs, this machine will start beeping and the AC icon on the screen will flash, and then the machine automatically shut down to ensure safely.
Package Content
Caution
- Do not short-circuit the product. To avoid short-circuiting, keep the product away from all metal objects.
- Do not heat the product, or dispose of it in fire, water, or other liquids. Keep it away from high ambient temperatures. Do not expose the product to direct sunlight.
- Keep the product away from humid, dusty places.
- Do not disassemble or reassemble this product.
- Do not drop, place heavy objects, or trample on this product.
- This product is not intended to be used by a person with reduced physical, sensory, or mental capabilities.
- Please keep this product away from children.
- Do not cover the product with towels, clothing, and other items.
- Do not overcharge this product.
- When fully charged, disconnect the product from the power source immediately.
- If you are not going to use this product for a long time, please disconnect the cable before storing it.
- To charge some portable electronic devices, you may need to set those devices in charge mode first. Refer to the corresponding user manual of those devices for confirmation.
- Do not pull the socket cover of the 12V DC Charging Port too hard, the tether could break.
Pure Sine Wave Output
This product generates a pure sine wave, which is compatible with AC electric
appliance that works with Sinusoidal waveform (power< 2000W ). The product is
perfect for off-grid power needs or backup power for emergency situations.
However, it cannot replace the standard DC or AC power supply for household
appliances.
Warranty
- Our company provides customers with a warranty of 12 months from the date of purchase.
- Customer Service: energizer@iittechnology.com.
© 2022 Energizer. Energizer and certain graphic designs are trademarks of Energizer Brands, LLC and related subsidiaries and are used under license by Tennrich International Corp.
Read User Manual Online (PDF format)