BRESSER 7009993 Wireless Thermo Hygrometer Instruction Manual

June 12, 2024
BRESSER

BRESSER 7009993 Wireless Thermo Hygrometer

General Warning

DANGER!
This device contains electronic components which operate via a power source (power supply and/or batteries). Do not let children use the device while unattended. Only use the device as described in the manual, otherwise you run the risk of an electric shock. Children should only use the device under adult su-pervision. Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as they pose a choking hazard. Keep batteries out of the reach of children. Make sure you insert the batteries correctly. Empty or dam-aged batteries could cause burns if they come into contact with the skin. If necessary, wear adequate gloves for protection.

DANGER!
Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion!

NOTE!
Do not disassemble the device. In the event of a de-fect, please contact your dealer. The dealer will con-tact the Service Centre and can send the device in to be repaired, if necessary. Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. The bat-teries should be removed from the unit if it has not been used for a long time.

Notes on cleaning
Separate the device from the power supply or remove the batteries before cleaning.

NOTE!
Only use a dry cloth to clean the exterior of the de-vice. Do not use any cleaning fluid to avoid damaging the electronics.

Disposal

Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.Do not dispose of electronic devices in the household garbage!
As per the Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner. In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Di-rective. Batteries that contain toxins are marked with a sign and a chemical symbol.

  1. battery contains cadmium
  2. battery contains mercury
  3. battery contains lead

TECHNICAL DATA

Temperature:

  • Measuring range: -20,0°C to +60,0°C
  • Accuracy: +/- 1°C
  • Resolution: 0,1°C

Relative humidity:

  • Measuring range: 25% to 90% relative humidity
  • Accuracy: +/-5%
  • Resolution: 1%

General:

  • Batteries: 2 pcs. UM-3 or “AA” 1.5V Transmission
  • frequency: 433MHz
  • Dimensions: 110 x 60 x 32 mm (H x W x D)

FEATURES OF THE REMOTE UNIT

BRESSER-7009993-Wireless-Thermo-Hygrometer-FIG-2

  • A BATTERY COMPARTMENT
    Unit requires 2 pcs. UM-3 or “AA” 1.5V batteries

  • B RESET
    Reset all functions after channel change.

  • C CHANNEL
    Input channel for the weather station. Set the chan-nel before inserting the batteries.

  • D WALL MOUNT
    For mounting the sensor on walls.

  • E DISPLAY (ON FRONT SIDE)
    Displays temperature, humidity, current channel and low battery warning symbol [ ].

  • F LED INDICATOR (ON FRONT SIDE)
    Flashes when signals are transmitted.

FIRST OPERATION OF THE THERMO-HYGROMETER

  1. Open the battery compartment cover on the back of the Thermo-Hygrometer.
  2. Set the desired channel with the switch (C). If you are using only one transmitter, please leave the selection at „1“.
  3. Insert 2 new UM-3 or „AA“ 1.5V batteries observ-ing correct polarity.
  4. Use a pin to press the „RESET“ – button located in the battery compartment.
  5. Close the battery compartment cover and set the unit in the desired location.

PLACEMENT TIPS:
Please observe the following guidelines to ensure optimal operation of the device:

  1. Assign each remote unit to it’s own channel.
  2. Place the receiver unit (Weather station) and remote unit (thermo-hygro sensor) within 1 meter to each other and enable the manual search for available signals of all remote units on the main unit (Weather station, not included) Do this by pressing the [▼] button on the back side of your weather station. Wait until the measured value appears on the display.
  3. Next, set the remote unit at a place where air circulation and sun protection is guaranteed. Please select a rainfall-free, shady place for measurement. The international standard height for temperature measurements is 1.25 m (4 ft) above the ground.
  4. When batteries are nearing depletion, the symbol [ ] is displayed on the sensor and weather station.

Note that the effective range is vastly affected by the construction material of nearby buildings as well as the position of the remote unit and possibly greatly reduced by external sources (various radio stations and other sources of interference). If no reception is possible, we recommend to try different locations for the weather station (not included) and remote unit. Sometimes all it takes is moving the device by a few inches!

EC DECLARATION OF CONFORMITY

Hereby, Bresser GmbH declares that the equipment type with part number: 7009993 is in compliance with Directive: 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address:
www.bresser.de/download/7009993/CE/7009993_CE.pdf

UKCA DECLARATION OF CONFORMITY

Bresser GmbH has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address: www.bresser.de/download/7009993/ UKCA/7009993_UKCA.pdf

WARRANTY & SERVICE

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms as well as information on extending the guarantee period and details of our services at www.bresser.de/warranty_terms.

Bresser GmbH

  • Gutenbergstr. 2
  • DE-46414 Rhede
  • Germany

Service:

Bresser UK Ltd.
Suite 3G, Eden House Enterprise Way, Edenbridge, Kent TN8 6HF, Great Britain

Errors and technical changes are reserved.

Manual_7009993_Thermo-Hygro-5CH-Sensor_de-en-fr-it-es_BRESSER_v052023a

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals