Introduction
Thank you for purchasing the Laser Distance Meter. The MT150 is a pen-shaped
laser distance meter and was specifically designed for indoor applications.
Shortcut and Soft grip keys for addition, subtraction, area and volume
calculation allow for fast and very
reliable measurement.
Features
- Bluetooth 4.0 with App support
- Built-in level vial
- Unit selectable (m, ft, in)
- Area, volume calculations
- Continuous measurement
- Min/Max distance tracking
- Reference level selectable
- Water and dustproof
- Backlight LCD display
- 3-line display
- Buzzer indication
Safety Instructions
- Use extreme caution when the laser beam is turned on.
- Do not point the beam into your eye, another person’s eye or the eye of an animal.
- Be careful not to point the beam on a reflective surface, striking your eye.
- Do not allow the laser light beam impinge on any gas which can explode.
CAUTION
LASER RADIATION DO NOT STARE INTO BEAM
DIODE LASER <1mW Output at 635nm CLASS II LASER PRODUCT
3.1. Permitted Use
-
Measuring distances.
-
Computing functions, e. g. areas and volumes.
3.2. Prohibited Use -
Using the instrument without instruction.
-
Using outside the stated limits.
-
Deactivation of safety systems and removal of explanatory and hazard labels.
-
Opening of the equipment by using tools (screwdrivers, etc.), as far as not specifically permitted for certain cases.
-
Carrying out modification or conversion of the product.
-
Use of accessories from other manufacturers without the express approval of by us.
-
Deliberate or irresponsible behavior on scaffolding, when using ladders, when measuring near machines which are running, or near parts of machines or installations which are unprotected.
-
Aiming directly into the sun.
-
Inadequate safeguards at the surveying site (e.g. when measuring on roads, construction sites, etc.).
Laser Classification
There is a visible laser beam which emerges from the front of the instrument.
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other people
unnecessarily. Eye‘s protection is normally afforded by aversion responses
including the blink reflex.
Inserting/Replacing Batteries
- Remove battery compartment lid.
- Insert batteries, observing correct polarity.
- Close the battery compartment again.
• Replace the batteries when the symbol “ “ flashes permanently in the display.
• Use alkaline batteries only.
• Remove the batteries before any long period of non-use to avoid the danger of corrosion.
Keypad
- ON/MEAS button
- CLR/OFF button
- MEM/Reference button
- Function ( ) /Unit button
LCD Display
- Laser active
- Reference level (front)
- Reference level (rear)
- Battery status
- Intermediate line 1
- Intermediate line 2
- Summary line
Initial Operation and Setting
8.1. Switching On and Off Switches on the instrument and laser.
Press this button longer to switch off the instrument.
The instrument switches off automatically after three minutes of inactivity.
8.2. Clear Button
The last action is cancelled or the data display is cleared. If in the mode of
History storage, press MEM button and Clear button simultaneously will clear
all storage data in the memory.
8.3. Reference Level Setting
The default reference setting is from the rear of the instrument.
Hold down this button to take the selection from the front edge , a special
beep sounds whenever the reference setting is changed. After a re-startup the
reference returns automatically to the default setting (rear reference).
8.4. Distance Unit Setting For Instrument
Click the button longer to change the next type of unit. The following unit
can be set:
| Distance| Area| Volume
---|---|---|---
1| 0.000 m| 0.000 m2| 0.000 m3
2| 0.0 in| 0.000 ft2| 0.000 ft3
3| 0 1/16 in| 0.000 ft2| 0.000 ft3
4| 0.000 ft| 0.000 ft2| 0.000 ft3
5| 0’00” 1/16| 0.000 ft2| 0.000 ft3
8.5. Measuring
8.5.1. Single Distance Measurement
Press to activate the laser. Press again to trigger the distance measurement.
The measured value is displayed immediately.
8.5.2. Continuous Measurement (Tracking) & Max and Min Measurement
The continuous measurement function (tracking) is used for the transferring of
measurements, e.g., from construction plans. In continuous measurement mode,
the measuring tool can be moved to the target, whereby the measured value is
updated approx.
every 0.5 seconds in the third line. The corresponding MIN and MAX values are
displayed dynamically in the first and second line. As an example, the user
can move from a wall to the required distance, while the actual distance can
be read continuously. For continuous measurement, hold down the button to
start the continuous measurement. Press or button again to stop the function.
The function is terminated automatically after continuous 100 times
measurement.
Functions
9.1. Area Measurement
Press the button once will start the area measurement function.
Press button to take the first length measurement (e.g. length).
Press button again to take the second length measurement (e.g. width).
The result of the area measurement is displayed in the third line, the
individually measured values are displayed in lines 1 and 2. Whilst the first
connection between the Phone/PC and the Laser distance meter is being
established, a prompt for the Pin-code of the instrument may be displayed. In
this case, enter the code 0000 into your Phone/PC.
9.2. Volume Measurement
Press the button twice will start volume measurement function.
Press button to measure the first distance (e.g. length)
Press button to measure the second distance (e.g. width).
The result of the area measurement from the values already measured is
displayed in the summary line.
Press button to measure the third distance (e.g. height).
The value is displayed in the second line. The result of the volume
measurement is displayed in the summary line, the two previously measured
values in lines 1 and 2.
9.3. Historical Storage
The previous 20 records (measurements or calculated results) are shown in the
reverse order. Use buttons to navigate through these records. You can clear
all records by pressing the Storage button and Clear button simultaneously in
historical storage mode.
9.4. Switching BLUETOOTH On
Hold down the button until the Bluetooth symbol disappears in the display.
Then you can use our Meterbox APP installed on your phone to connect with this
instrument.
9.5. Switching BLUETOOTH Off
Hold down the button until the Bluetooth symbol disappears in the display.
BLUETOOTH is disabled when the instrument is turned off.
Measuring Conditions
10.1. Measuring Range
The range is limited to Technical Specifications.
10.2. Target Surfaces
Measuring errors can occur when measuring toward colorless liquids (e.g.
water) or dust free glass, Styrofoam or similar semi-permeable surfaces.
Aiming at high gloss surfaces may deflect the laser beam and lead to
measurement errors. Against non-reflective and dark surfaces the measuring
time may increase.
10.3. Care
Do not immerse the instrument in water. Wipe off dirt with a damp, soft cloth.
Do not use aggressive cleaning agents or solutions.
Handle the instrument as you would a telescope or camera.
10.4. Troubleshooting – Causes and Corrective Measures
Code | Cause | Corrective Measure |
---|---|---|
208 | Received signal too weak, measurement time too long. Distance>50m | Use |
target plate
252| Temperature too high| Cool down instrument
253| Temperature too low| Warm up instrument
255| Hardware error| Switch on/off the device several times, If the symbol
still appears, please contact your dealer for assistance.
Specifications
Function | Range |
---|---|
Range (Use target plate from ±50m) | 0.05 to 50m (0.2 to 164ft) |
Measuring accuracy up to 10m (2a, standard deviation) | Typically: ±1.5mm |
(±1/161n)
Measuring units| m, in, ft
Laser class| Class II
Laser Type| 650 nm, <1mW
Smallest unit displayed| 1mm
Range of BLUETOOTH| 10m
IP54 Housing| Dust resistant / Splash proof
History measurement records| 20
Keyboard Type| Super Soft-Touch (Long life)
Operating Temperature| 0°C to 40°C (32°F to 104°F)
Storage Temperature| 10°C to 60°C (14°F to 140°F)
Batteries| 2 x AAA
Battery Life| up to 5,000 measurements
Auto laser switch-off| after 30 seconds
Auto instrument switch-off| after 3 minutes
Dimensions| 135 x 33 x 24mm
Weight| 80g
- Use a target plate to increase the measurement range during daylight or if the target has poor reflection properties.
- In favorable conditions (good target surface properties, room temperature) up to 10m (33ft). In unfavorable conditions, such as intense sunshine, poorly reflecting target surface or high temperature variations, the deviation over distances above 10m (33ft) can increase by ±0.15mm/m (±0.0018in/ft).
MAJOR TECH (PTY) LTD