INTRODUCTION

The MT667 is a digital microprocessor controlled Thermo-Hygrometer with fast response and high accuracy with Dew point, Wet bulb and Temperature measurements. The Wet Bulb mode is effectively a Digital Sling Psychrometer.
It is an ideal instrument for scores of practical applications for Laboratory, Industrial, Engineer and Professional use. This offers a wide variety of applications ranging from HVAC to laboratories, and is ideal in other industries such as computer rooms, hospitals, tobacco industry, factories and offices and general use.
The Humidity & Temperature Meter uses a humidity & temperature semiconductor sensor. This operation manual contains general information and specification.

FEATURES

  • Fast Response Time %RH: 10s (90% at 25°C still air)
  • High Accuracy
  • Dew Point Temperature (-30°C to 100°C)/(-22°F to 199°F)
  • Wet Bulb Temperature (0°C to 80°C)/(32°F to 176°F)
  • Resolution 0.01%RH, 0.01°C/0.01°F
  • Max Hold and Data Hold Function
  • Micro Processor-based Design
  • Dual Display Temperature & Humidity
  • Auto Power Off, Disable Sleep Mode
  • Back light
  • Mini Size

SPECIFICATIONS

Function Range
Display Large 4½ dual digital LCD display with back light
Sensor Type A single chip relative humidity and temperature

multi sensor module comprising a calibrated digital output.

Response Time| %RH:105 (90% at +25°C still air)
Accuracy Note| Accuracy is specified for the following ambient

temperature range: 18 to 28°C (64 to 82°F)

Sampling Rate| 2.5 samples per second
Polarity| Automatic, (-) negative polarity indication.
Over-range:| “OL” mark indication.
Low Battery

Indication

| The ”      ” is displayed when the battery voltage

drops below the operating level.

Operating Conditions| 0 to 40°C (32 to 104°F); < 80% RH non-

condensing

Storage Conditions| -10 to 60°C (14 to 140°F); <80% RH non- condensing
Auto Power Off| Meter automatically shuts down after approx.15 minutes of inactivity (Sleep Mode) To override Auto Power Off function (Non-Sleep Mode): First press hold/backlight button, then press the power button. After the full display appears, release both buttons. lcon ” ” will not show on the LCD. The unit will not auto power off now.
Power| One standard 9V, NEDA1604 or 6F22 battery.
Dimensions/Wt.| 225 (H) x 45 (W) x 34 (D) mm/200g

Humidity / Temperature Measurement Range

Function Range
Humidity 0%~100%RH
Temperature -30°C ~ 100°C, -30°F ~ 199°F
Resolution 0.01% RH, 0.01°C/°F.
Humidity Accuracy ±2%RH (at 25°C, 20%~80% RH).

±2.5%RH (at other ranges)

Air Temperature Accuracy| ±0.5°C+ 0.9°F (at 25°C)

±0.8°C/+ 1.5°F (all other ranges)

Note: The measuring range is from 0% to 100%, but above 80% and below 20% the deviation is not specified.

PANEL DESCRIPTION

MAJOR-TECH-MT667-Thermo-Hygrometer-1

  1. Humidity / Air Temperature
    Probe: Humidity & and Temperature Semiconductor Sensor inside.

  2. LCD Display: 4½ dual digits
    LCD display with units of °C, °F, %RH dew point, wet bulb and low battery “BAT” MIN /MAX HOLD, indication.

  3. MAX/ MIN Button: Press
    MAX/MIN button to enter MAX, MIN Recording mode (manual range only). Select the proper range before selecting MAX MIN to ensure that the MAX/MIN reading will not exceed the testing range. Press once to select MIN. Press again to select MAX. Press and hold the Button for over 2 second to turn off MAX, MIN Recording.

  4. °C, °F, Dew Point, Wbt
    Select Button: Press °C, °F, Dew Point, Wbt select Button to enter select °C, °F, Dew Point, Wet Bulb Measurement.

  5.  Power ON/OFF Button: Turn
    the meter power ON/OFF.

  6. HOLD /Back light Button:
    Press Hold/backlight Button to enter hold function. The reading will be held when Data Hold button is pressed. Press Hold/backlight Button for over 2 seconds to turn on or off back light function.

  7. Battery Compartment

HUMIDITY AND AIR TEMPERATURE MEASUREMENTS

  1. Hold the probe in the area to be tested & allow adequate time for readings to stabilize.
  2. Press °C, °F, dew point, WBT select Button to enter select °C, °F, dew point Wet Bulb Measurement.
  3. Read the Relative Humidity and Air Temperature, dew point temperature wet bulb temperature.

NOTE: Do not immerse the probe in liquid; it is intended for use in air only.
WARNING: Don’t expose the sensor to direct sunlight (in solation). Don’t touch or manipulate the sensor.

BATTERY REPLACEMENT

If the sign ” ” appears on the LCD display, it indicates that the battery should be replaced. Open the battery case and replace the depleted battery with a new battery. (1 x 9V battery NEDA 1604, 6F22 or equivalent).

MAJOR TECH (PTY) LTD

South Africa
www.major-tech.com 
sales@major-tech.com

Australia
www.majortech.com.au
info@majortech.com.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

MAJOR TECH User Manuals

Related Manuals