PHILIPS RC530B LED34S-940 SRD W8L120 VPC User Guide

June 12, 2024
Philips

TrueLine
RC530B ELP3/ELD3PHILIPS RC530B LED34S 940 SRD W8L120
VPC

RC530B LED34S-940 SRD W8L120 VPC

PHILIPS RC530B LED34S 940 SRD W8L120 VPC - RecessedPHILIPS RC530B LED34S 940 SRD W8L120 VPC -
indoor

| | | A| B| VPC| PCV
---|---|---|---|---|---|---
Recessed| VPC| W8L150| 1497| 1450| 4.3|
Recessed| PCV| W8L145| 1472| 1450| | 4.4
Recessed Line| VPC/PCV| W8L145| 1448| | 4.2| 4.5

PHILIPS RC530B LED34S 940 SRD W8L120 VPC - Fig

**** Minimal build-in dimensions to avoid overheat [mm]

PHILIPS RC530B LED34S 940 SRD W8L120 VPC - overheat

| 4ft| 5ft
---|---|---
Height| 120| 120
Width| 400| 400
Length| 1400| 1700

The luminaire shell under no circumstance, covered with thermal insulation matting or similar material

442200451908

583 – 442200451908
© 06/2021, Signify Holding. All rights reserved.
Printed in Hungary
Data subject to change without notice
Keep for future reference: www.lighting.philips.comPHILIPS RC530B
LED34S 940 SRD W8L120 VPC - Fig 1PHILIPS RC530B LED34S 940 SRD W8L120 VPC - Fig
2PHILIPS RC530B LED34S 940 SRD W8L120 VPC - Fig
3PHILIPS RC530B LED34S 940 SRD W8L120 VPC - Fig
4PHILIPS RC530B LED34S 940 SRD W8L120 VPC -
Replacement batteries

Battery Unit

Manufacturer| Unit| Power| Duration| Number of cells| Nominal voltage| Luminous flux
---|---|---|---|---|---|---
Philips| TrustSight 3.2V 3cell 4500mAh battery LFP| 2 W| 3 h| 3| 3.2 V|  310 lm

Inrush current

Imax.(A)|
---|---
Tref(µs)|
MCB
B-10A| Luminaires Max.
15
B-13A| 19
B-16A| 24
B-20A| 30
B-25A| 37
C-10A| 24
C-13A| 32
C-16A| 40
C-20A| 49
C-25A| 62

Rated lumen in emergency mode for OC 310lm.

Rated lumen in emergency mode for NOC 230lm.

PHILIPS RC530B LED34S 940 SRD W8L120 VPC - Icon 2

The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Given the choices made in this unique lighting concept, there are a few instructions regarding the maintenance.

  • Prevent water from entering on or in the luminaire at installation and during use of the luminaire
  • During installation or maintaining the luminaire please use gloves to avoid spots on the cover.
  • Do not clean with a dry cloth as it will cause the product to attract dust. Dirty spots can be removed:

Only dust: use a damped cloth (no dripping water), preferably anti-static.
Fingerprints etc: use a damped cloth (no dripping water) with a cleaner approriate for polycarbonate/PMMA plastics

  • Do not touch electronic components as they are ESD sensitive.
  • Do not stare into LED beam.
  • Luminaire should not be used for illumination during building activities due to dust accumulation inside the luminaire.

LASER RADIATION
AVOID DIRECT EYE EXPOSURE
CLASS 2M LASER PRODUCT 210J/M2/10S 443.533.552nm
wg PN-EN 60825-1 -2005

PHILIPS RC530B LED34S 940 SRD W8L120 VPC - Fig 5http://www.lighting.philips.com/main/systems/themes/service- tag.htmlPHILIPS RC530B LED34S 940 SRD W8L120 VPC - Fig
6

To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).

PHILIPS RC530B LED34S 940 SRD W8L120 VPC - QR Code 1https://play.google.com/store/apps/details?id=com.philips.servicetag

 Disconnect before servicing
Luminaire has basic insulation between Low Voltage supply and control conductors.
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.
This product contains a light source of energy efficiency class: see table or label.

© 2020 Signify Holding
All rights reserved. Reproduction in whole or in part is prohibited without the prior written consent of the copyright owner.
The information presented in this document does not form part of any quotation or contract, is believed to be accurate and
reliable and may be changed without notice. No liability will be accepted by the publisher for any consequence of its use.
Publication thereof does not convey nor imply any license under patent- or other industrial or intellectual property rights.
Signify Holding.
The Netherlands

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals