KONIFERA 19087 Gartenhaus »Carlberg 6«, (Set) BxT: 337×341 cm Instructions

June 12, 2024
KONIFERA

19087 Gartenhaus »Carlberg 6«, (Set) BxT: 337×341 cm
InstructionsKONIFERA 19087 Gartenhaus Carlberg 6

19087 Gartenhaus »Carlberg 6«, (Set) BxT: 337×341 cm

Das komplette Farbangebot finden Sie auf: www.KARIBU- FARBENSHOP.dehttps://www.karibu- farbenshop.de/
Karibu Holztechnik GmbH
Eduard-Suling-Str. 17
28217 Bremen info@karibu.de

First compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only!
KONIFERA 19087 Gartenhaus Carlberg - figure 1 KONIFERA 19087 Gartenhaus Carlberg - figure 2

Not included

  1. Length must be determined and sawn
  2. Not needed
  3. with accessories!
  4. Fixed temporarily

KONIFERA 19087 Gartenhaus Carlberg - figure 3KONIFERA 19087 Gartenhaus Carlberg - figure
4KONIFERA 19087 Gartenhaus Carlberg - figure
5 Glue! Look for the same height
KONIFERA 19087 Gartenhaus Carlberg - figure 5KONIFERA 19087 Gartenhaus Carlberg - figure
6KONIFERA 19087 Gartenhaus Carlberg - figure
7KONIFERA 19087 Gartenhaus Carlberg - figure
8KONIFERA 19087 Gartenhaus Carlberg - figure
9KONIFERA 19087 Gartenhaus Carlberg - figure
10KONIFERA 19087 Gartenhaus Carlberg - figure
11

Roofing felt intallation **

**

Note! This description is only an example!
The bitumen roofing is used for initial cover and should be supplemented by a separate product according to customers choice after two months. The number of bitumen strips to be used depends on your actual house size. When joining rolls of roofing felt end to end, the overlap must be aproxximately 10cm. The roof is not safe to walk on. The roof is designed for a total load (snow. wind) and not for a point load. We recommend you to always support the roof from below during installation. The sealing of the roof surfaces to adjacent components with bitumen sealant has to be effected by the customer! If it is a saddle-roofed house. do not use roofing tiles for roofing. In this case. a 20 cm wide strip of bitumen with overhang should be installed on both sides of the eaves. For houses with a tonne roof, please install a bitumen roofing under the shingles. In the case of a flat roof the laying of roof shingles is not possible! KONIFERA 19087 Gartenhaus Carlberg - figure
12 KONIFERA 19087 Gartenhaus Carlberg - figure
13 KONIFERA 19087 Gartenhaus Carlberg - figure
14 KONIFERA 19087 Gartenhaus Carlberg - figure
15

Installation door

KONIFERA 19087 Gartenhaus Carlberg - figure 16 KONIFERA 19087 Gartenhaus Carlberg - figure 17 KONIFERA 19087 Gartenhaus Carlberg - figure 18 KONIFERA 19087 Gartenhaus Carlberg - figure 19 KONIFERA 19087 Gartenhaus Carlberg - figure 20 KONIFERA 19087 Gartenhaus Carlberg - figure 21

Handling • Maintenance • Care of the door of the door

The guarantee is conditional on proper upkeep!
For lasting protection of the value and suitability for use, professional care and maintenance is also recommended during the warranty period; this is not included in the warranty obligations. Defects must be repaired immediately upon detection.
Wood protection treatment of the door
All parts of the door must receive wood protection treatment. Those sections of the wood, which will not be accessable after installation, should receive complete treatment before installation.
Treat the product with a blue stain blocking coat; afterwards apply a double protective coating of an open-pored wood-protection glaze. Application of a protective coating should be repeated at least every two years.
Please beware that the inserted plates of other material may come to differ in colour to the doors if you use unsuitable coating material. With coloured and boiler pressure impregnated houses, only the exposed natural wood (saw cuts) and parts should need extra treatment.
You can obtain an even colour covering in inside areas with one coat of paint. For that you should use an open-pored, acrylic based water dispersed lacquer. In order to guarantee a long service life of your product you should repair damaged areas immediately. Do this by whetting the damaged area and apply a new coat of paint. Enquire about suitable glazes at your local paint retailer.
Furthermore, you can seal the joining of the wood-window pane with a suitable sealant to guarantee a long service life of the door and prevent leakage from heavy rain. If these precautions of care are not properly carried out, it can result in deformation, blue stain, fungus infestation in the doors and frames and loss of warranty.
Cleaning
Regular cleaning and care is a prerequisite for preserving the service life and functionality of high-value products. Cleaning is to take place outside, inside and also in the rabbet-area. The cleaning agent used must be suitable for the relevant material; please do a test before you start cleaning.
Deformation of the door
Wood reacts to environmental infl uences. Weather exposure will lead to swelling and contraction of the wood. This causes variances of dimensions and slight deformation. Dependant on the weather exposure, the door may need realignment by turning the hinges in- or outwards. Some door warpage is acceptable as long as the door can be made to function through the alignment options specifi ed here. The warranty does not cover damage caused by use of excessive force.
Adjustment of the door
The door must be accurately adjusted to ensure trouble-free operation. The door frames must be installed right-angled and perpendicular. Furthermore, they must be installed so the width of the frame is the same at the top and bottom. If the door doesn’t close or if one panel is askew, this can be rectifi ed by limited in- or outwards turning of the hinges. You can turn the hinges outwards up to 5 rotations. If you have a double-door, the door to be secured must always be correctly aligned at the top and bottom with the appropriate hinges. KONIFERA 19087 Gartenhaus Carlberg - figure 2269044

KONIFERA 19087 Gartenhaus Carlberg - figure 23 Building Instructions

Service-Hotline:+49 421 38693 33
First compare the list of materials with your package contents! Please understand that complaints can be processed in the non-built status only! KONIFERA 19087 Gartenhaus Carlberg - figure 24 KONIFERA 19087 Gartenhaus Carlberg - figure 25