Product Information

  • Product Model: SFF1546N

  • Technical Manual: Available

  • Characteristics: Klimaklasse C, Sicherheitsklasse 1

  • Outside Dimensions: 800x850x2000 mm

  • Inside Dimensions: 680x430x1078 mm

  • Freezing Temperature: -18°C

  • Thermostat Set Temperature: -30°C

  • Ambient Temperature: +38°C

  • Humidity: 65%

  • Energy Consumption: 3 KW/H

  • Power: 3.50 KW

  • Voltage – Frequency: 380V / 50 Hz

  • Digital Thermometer: Included (1 piece)

  • GN Tray Capacity: 15x GN 1/1 + EN 400 x 600 mm

  • GN Tray Holders: 15x GN 1/1 brackets (4 pieces)

  • Technical Characteristics: INOX 304 SB+PVC, INOX 304 MAT+PVC,
    Insulation Material Thickness: 60 mm, Insulation Material Volume: 42 Kg/m3 +/-1

  • Weight: Gross: 200 kg, Net: 180 kg

  • Compressor: DORN H300CS–3 HP R404A-R452A

  • Fan Motor: Hidria R11R – 40LPS-4M-5150 190/260W-0,85/1,1 A 1310/1450 Rpm 50/60 Hz

  • Refrigerant: R404A / R452A (3000 gr)

  • Standards: EN 60335-2-89 and EN 60335-1

  • Packaging: Wooden Pallet, Packed in Cartons and Nylon

Product Usage Instructions:

  1. Place the SFF1546N in a suitable location with enough space for proper ventilation.
  2. Ensure that the ambient temperature does not exceed +38°C and the humidity is kept at around 65%.
  3. Connect the product to a power source with a voltage of 380V and frequency of 50 Hz.
  4. Set the thermostat temperature to -30°C for optimal freezing.
  5. Use the included digital thermometer to monitor the temperature inside the unit.
  6. Load the GN trays into the unit, ensuring they fit securely on the 15x GN 1/1 brackets.
  7. Make sure the door is properly closed to maintain the freezing temperature.
  8. Regularly check and clean the evaporator, fan cover, and condenser for optimal performance.
  9. If any spare parts need replacement, refer to the SFF1546N Spare Part List in the user manual.

DIMENSIONS

  • OUTSIDE DIMENSIONS = 800x850x2000ggm-gastro-SUN2000-On-Grid-Solar-Inverter-fig-1
  • INSIDE DIMENSIONS = 680x430x1078

CHARACTERISTIC SPECIALITIES

 Climate class Safety class Cooling temperature Freezing temperature| :N
:1
:+90 / +3C
:+90 / -18C
Thermostat set temperature :-30C
Ambient temperature| : +38C
Humidity| : %65
Energy consumption Power

Voltage – Frequency

| : 3 KW/H
: 3,50 KW
: 380V / 50 Hz
ACCESORIES AND CONTROL SWITCHES
Digital thermometer| : Digitales Thermometer /Digital thermometer

: Stk. / Pcs. 1

: Stk. / Pcs. 4

:15x GN 1/1 + EN 400 x 600 mm

:15x GN 1/1 Halterungen / :15 x GN 1/1 brackets

Hinge group
Stand
Shelf
TECHNICAL CHARACTERISTICS
Outside dimensions Inside dimensions Packing Cooling volume Freezing volume Gross weight Net weight External housing Internal housing| : 800x850x2000mm
: 680x430x1078mm
: 900x950x2160mm
: 35 kg
: 30 kg
: 200 kg
: 180 kg
: 0,60 mm INOX 304 SB+PVC
: 0,50 mm INOX 304 MAT+PVC
Insulation material thickness: 60 mm

Insulation material volume: 42 Kg / m3 +/-1

Compressor  Condenser Condenser fan| : DORİN H300CS–3 HP R404A-R452A

: 3,4 KW

:Hidria R11R – 40LPS-4M-5150

190/260W-0,85/1,1 A 1310/1450 Rpm 50/60 Hz

Evaporator Evaporator fan| : 1,76 KW

: EBM 72/90W , A4E300 , 1320/1500 RPM

0,32-0,4 A Axiallüfter x 3 / Axial fan x 3

Refrigerant  Gas quantity

Certifications Serial No Package

| : 3/8

: R404A / R452A

: 3000 gr

: EN 60335-2-89 ve EN 60335-1

: Auf der Verpackung / On the packaging

: Holzpalette , Verpackt in Karton und Nylon / Wooden pallet , Packed in carton and nylon

ggm-gastro-SUN2000-On-Grid-Solar-Inverter-fig-2

NR.| DESCRIPTION| ANZAHL

QTY

---|---|---
1| DOOR| 1
2| DOOR GASKET| 1
3| HINGE| 1
4| HINGE| 1
5| HINGE| 1
6| HINGE WITH BUSH| 1
7| EVAPORATOR| 1
8| EVAPORATOR FAN EBM 72/90| 3
9| FAN COVER| 3
10| FAN COVER| 1
11| RACK| 4
12| RACK RAIL| 28
13| PLATE| 1
14| VBL-15 CONDANSER| 1
15| FAN MOTOR| 1
16| FAN COVER| 1
17| COMPRESSOR – H300CS| 1
18| DRYER| 1
19| WATER TANK| 1
20| STAINLESS STEEL LEG| 4
21| PLUG CABLE| 1
22| PROBE – 3m| 1
23| FREEZER TANK| 1
24| PRESSURE SENSOR| 1
25| PROBE| 1
26| PROBE – 1,5m| 1
27| SOLENOID VALVE 3/8| 1
28| DIGITAL LABEL| 1
29| EVCO EVX805| 1
29| DIXELL XB07PR| 1
30| SWITCH (EVAPORATOR)| 1
31| PROBE COVER| 1
32| TOUCH CONTROL PANEL| 1
33| WHEEL WITHOUT BRAKE| 4
34| WHEEL WITH BRAKE| 4
35| DOOR FRAME| 1
36| EXPANSION VALVE NEEDLE| 1
37| EXPANSION VALVE| 1

ggm-gastro-SUN2000-On-Grid-Solar-Inverter-fig-3