AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual

June 12, 2024
AIRQUALITY

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User
Manual

Thank you for purchasing Air Quality sterilizing purifier

  • Please read this manual carefully before use.
  • Keep in mind the “Safety Precautions” in the manual to ensure safe operation.
  • The product appearance is subject to the material object.
  • Please use this product indoors.

Product Introduction

Airquality Technology (Shanghai) Co., Ltd. is established by a joint venture from Spanish company Herver-9 S.L. and Super Merit Holdings Limited. Super Merit Holdings Limited, one of the world’s first professional institutions focusing on the field of air purification, has been committed to the long-term development and application of air clean technologies for a long time.

Micro-electrostatic technology can produce strong electric field, which exerts great attraction on the moving charged particles in the air to adsorb the moving particles, especially for PM2.5 and other particulate pollutants. Meanwhile, the strong electric field can kill the bacteria, viruses and other micro organisms that are attached to the particles through micro discharge to avoid secondary pollution.

Micro-electronic filter needs no replacement and can be washed repeatedly, thus no extra cost on material replacement.

Japan M8 formaldehyde filter (Optional) can absorb and decompose formaldehyde stably for a long time. Due to no secondary pollution, it completely solves the formaldehyde pollution problem caused by decoration and effectively improves indoor air environment, thus it can give customers lasting protection and make them have long-term health.

400 cubic meters per hour of high clean air delivery rate (CADR) to meet the needs of the large space. Three-dimensional circulating air can rapidly remove hair, scurf, soot, pollen and the particulate matter smaller than 2.5 micrometres (PM 2.5) which can go directly to the alveoli of the lungs and undesirable odor, formaldehyde, benzene homologs and other harmful substances in the air, in the room, so the filter is the best choice for living room, office and other large spaces.

More intelligent experience. The particle sensor can comprehensively monitor the smoke, dust, PM2.5, and others in the room, that is, Realtime air quality indicator light, it can “see” air quality. Its intelligent mode can automatically regulate the sterilizing speed, its sleep mode, scheduled shutdown and child safety lock function make the MESP Air sterilizing purifier more user-friendly. The standby power less than 2W makes it be more environmentally-friendly and economical.

Safety Precautions

In order to avoid injury or loss to yourself or others, please read the following safety precautions. If you transfer this product to other customers, please transfer this manual as well

⚠ Warning

The following information relates to personnel safety and must be strictly observed. This product is suitable for indoor use. It is prohibited to use this product in the following places:

  • Where oil or combustible gas is used and leakage may occur.
  • Where there is corrosive gas and metal dust.
  • Places with high humidity like bathroom or places with heavy oil smoke like kitchen.
  • If the power cord is damaged, in order to avoid danger, it must be replaced by professionals from the manufacturer, its maintenance department or similar departments.
  • This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Safety
Precautions

Components Description

Components Breakdown

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Components
Breakdown

Back

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual -
Back

Usage

⚠ Cautions
Before using the product for the first time, install the M8 formaldehyde filter (Optional) as follows: (only for optional M8 formaldehyde filter, the standard configuration can be used with direct power on)

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual -
Usage AIRQUALITY KJ400F-01A
MESP Air Sterilizing Purifier User Manual - Usage

Product Operation

Instructions of Control Panel

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual -
Instructions of Control Panel

Instructions for Function Operation

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual -
Instructions for Function Operation

⚠ Cautions
The air quality indicator light displays as follows in color:
The sensor can detect the particulate pollutant in the air that is greater than 1 micron, the blue/ yellow/ red indicator light could detect the absorbable particulate pollutant concentration level in the air, blue indicates clean, yellow indicates pollution, and red indicates severe pollution.

Maintenance

⚠ Warning

  • Before maintenance, please shut down the sterilizer and disconnect the power supply!
  • Reset button will blink once the cleaning time is up, and then remove the filter to wash with water and dry in the air, press reset button for 3s to retiming the cleaning time.
  1. Cleaning of the machine When there is dirt on the surface of the machine, it can be wiped with the soft cloth, which is immersed in water, after being dried. When the dirt is hard to clean, it can be wiped with the soft cloth that is dipped with a small amount of alcohol. In case the air inlet and outlet are dirty, the dirt can be cleaned with a soft brush first, and then wipe them with a soft cloth.
    It is forbidden to wash the machine body directly with water.
    It is forbidden to wipe the fuselage with gasoline, volatile oil, diluent, etc.

  2. Sensor cleaningAIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Sensor cleaning

  3. Cleaning of anion needle

In order to obtain better sterilizing effect, it is necessary to keep the anion needle clean. The anion needle is located inside the air outlet (as shown in the left figure), which are two metal needles. Use the attached brush to extend into the machine from the air outlet and brush off the dust on the two metal needle tips. It is recommended to clean once a month.

Maintenance

4.Cleaning and replacement of filter
4.1 Cleaning of pre-filter

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Cleaning
of pre-filter

4.2 Cleaning of M8 formaldehyde filter (Optional)

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Cleaning
of M8 formaldehyde filter

4.3 Cleaning and drying of micro-electrostatic filter

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Cleaning
and drying of micro-electrostatic filter

⚠ Cautions

  • When the micro-electrostatic filter is just taken out of the machine, please do not touch the exposed metal electrode with your hand. The electrode may still have static electricity because the charge stored in the filter is not released completely! Please leave it for 30 minutes before operation.

  • When cleaning the filter, if you need to use cleaning agent, please thoroughly wash the cleaning agent until there is no obvious residue.

  • Please do not use water above 50 to clean the micro-electrostatic filter.

  • Please do not use the method of more than 50 to dry the filter, which may cause discoloration and deformation of the filter and make it unusable.
    Tips

  • The filter can be sprayed or soaked with 75% medical alcohol.

  • Do not use strong oxidants, such as chlorine (84 disinfectant), guanidine, quaternary salts, iodine, aldehydes, phenols, peroxides, ozone and other corrosive disinfectants for pre-disinfection.

  • After cleaning, micro-electrostatic filter may not restore its original color, which is a normal phenomenon and does not affect the performance of the filter.

  • If the micro-electrostatic filter is not dried sufficiently after cleaning and there is a small amount of water inside, the performance of the filter will be affected. In case of continuous use, the filter performance will recover naturally after the water disappears.

Specification Parameters

Drying methods of micro-electrostatic filter
The excess water in the micro-electrostatic filter must be removed before the drying operation. According to the direction of the four sides of the micro- electrostatic filter throw them out successively, at least three times in each direction, until there is no obvious water point. And dry the water drop on the surface with a dry soft cloth. Natural drying method: place the opening side of the micro electrostatic module downward, and dry in a cool and ventilated place for two hours, then it can be used normally.

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual -
Specification Parameters

Troubleshooting

When you suspect that the product is faulty, please confirm the cause of the phenomenon as described in the following table and handle it.

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual -
Troubleshooting

Packing list

AIRQUALITY KJ400F-01A MESP Air Sterilizing Purifier User Manual - Packing
list

Special Instructions

  1. The micro electrostatic technology was tested by Guangzhou Institute of Microbiology. In the 30 m3 test chamber, After 60 minutes of operation, 3 times results of decay rate of natural bacteria in the air all greater than or equal to 90 %
  2. The micro electrostatic technology was tested by Guangzhou Institute of Microbiology. In the 10 m3 test chamber, 3times of disinfection rate of Staphylococcus albus all greater than or equal to or 99.90% after 60 minutes of operation.
    In order to continuously improve product quality and meet users’ need, the Company has the right to make appropriate changes to product specifications, No further notice will be given at that time. Please understand.

Take a deep breath!!

Airquality Technology (Shanghai) Co., Ltd.
Add: No.1199, Yixian Road, Baoshan District, Shanghai,PRC
Postal code: 200439
Email: [email protected]
400 Hotline: +86 4007-288-696

If you want to learn more about AirQuality, please visit: Official website: http://en.airquality.com
Sina Weibe: @AirQualityTechnology (Shanghai) Co., Ltd.

In order to continuously improve product quality and meet the customer’s requirement, we will not send any notice additional in case there is any data change. Thank you very much for understanding.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AIRQUALITY User Manuals

Related Manuals