Product Information

The smart combustible gas alarm (called alarm for short hereinafter), is used to detect natural gas(CH4), the built-in semiconductor gas sensor has a long lifespan and tiny sensitivity drift, when the natural gas iS detected and exceeds the alarm concentration, the alarm will send out sound and light alarm signal immediately, at the same time, the valve manipulator turns off the gas valve automatically, the real-time alarm will also sent to users’ APP. The alarm is suitable for indoor use and should be installed at places where natural gas leakage may happen.

Packing List

Product Picture

Valve manipulator description

tuya-Smart-Combustible-Gas-Alarm-FIG-3

Features

  1. Highly stable gas sensor
  2. Self test by APP
  3. Voice prompt
  4. Report alarms to smart phone in real time
  5. APP controls valve manipulator
  6. Plug and play
  7. Once gas leakage is detected,manipulator turns off gas valve automatically

Technical Data

  1. Working voltage: AC100V ~ 240V
  2. Average power consumption: ≤3W
  3. Warm-up time: About 3 minutes
  4. Detected gas : Natural gas (CH4)
  5. Alarm sensitivity: 6%LEL(‡3%LEL)
  6. Alarm: Red LED flashes + voice prompt
  7. Fault: Yellow LED flashes + voice prompt
  8. Sound level: ≥70dB(1m away)
  9. Alarm mode: Acousto – optic alarm
  10. Auxiliary output: Valve manipulator output
  11. Valve manipulator jack output: 11~13V, 500mA
  12. Network: WiFi-2.4GHz
  13. Working temperature: -10°C ~ +55°C (indoor use only)
  14. Storage temperature: -20°C ~ +60°C
  15. Working humidity: <95%RH (no condensation)
  16. Installation: Wall mounting, plug and play
  17. Dimension: L89.5mm×W89.5mm×H38mm (plug not included)

Tips for usage

  1. The shell surface has a slight heat while working is normal.

  2. Please dismount the alarm when your house is under renovation.

  3. Avoid spraying aerosol around the alarm.

  4. The semiconductor supports five years lifespan, please replace it timely.

  5. Forbidden to use lighter to test the alarm in case of any damage to the alarm.

  6. After used for a period of time, if there is oil adhered on the gas convection holes, which affects the sensitivity of the alarm, it’s suggested that the user takes the brush to clean the gas convection holes with detergent every three months. But don’t let the detergent enter into the alarm body.
    After every cleaning, do a test to check if the alarm can work normally.

  7. The alarm is used to detect the natural gas, and can’t be used to extinguish the fire.

  8. The alarm is used to detect the natural gas, and can’t be used to detect CO and other harmful gases.

  9. In addition to proper usage of the alarm, the user also should be on alert and strengthen security awareness in daily life.

Tips for mounting

  1. As the natural gas is lighter than the air, please mount the alarm 0.3~ 1 m below the ceiling vertically and 1.5m away from the natural gas source.
  2. Install a socket in a suitable position, and insert the alarm plug into the socket.
  3. The alarm should be mounted 1m away from the cooker to avoid too near to the cooker fire and oily fume, which may cause false alarm or affect sensitivity of the sensor. It’s also suggested that the sensor be not mounted near the exhaust fans, windows, doors or bathrooms where it’s full of vapor.

Installation diagram

Functions

  1. Power on: green LED indicator on and voice prompt on.
  2. Aarm-up mode: green, red and yellow LED indicator flashes in turn. 3 minutes later, green LED indicator will keep on, and the voice prompt will issue: Starting finished, you can use it now. Warming:It’s forbidden to do gas test during warm-up.
  3. When the natural gas exceeds the alarm concentration,the red LED indicator will flash (twice /second), and the vioce prompt will issue “Attention, Gas is leaking.” And the buzzer will beep too.
  4. When inner sensor fault is happening, yellow LED indicator will keep on and voice prompt will issue” Sensor failure, +buzzer beeps”. In this case, please power off the sensor and contact local distributor for repairing.
  5. It’s forbidden to disassemble privately, otherwise electric shock may be incurred.

Product testing

  1. Test button is used to test whether LED or buzzer can work normally. Press the button no more than 3 seconds, red, green and yellow LED indicator will flash in turn ( once/second) and the voice prompt will issue “Self-testing now”.
  2. Press the test button for more than 3 seconds, the valve manipulator will be on or off automatically. The alarm can tell the status of the valve manipulator
  3. Please don’t use lighter to test the alarm in case of any damage to the alarm. The user may store the gas of a lighter into an empty plastic bottle, then open the bottle mouth toward the gas convection holes to do the test.

Quick setting

  1. Download App
    Scan the QR code below to download the
    Ezykam+ APP and register a user account.

  2. Connect new devices
    Power on the alarm, after warming up is finished, the green LED will keep on, then connect the mobile phone to WiFi ( WiFi must be available ). Open the Ezykam+ APP and login.
    The alarm should be installed in areas within the WiFi signal coverage.

Add new devices
Click “+” on the APP to add a new device
Select “Smart Home” > Gas Detector (Wi-Fi)
Press and hold the networking button for 5 seconds, then input WiFi password according to the APP prompt. after that, tap “Confirm” to start connecting process, when the device is connected successfully, the WiFi LED will be off. Status of LED indicator and voice prompt

  1. LED indicator for network Connection statustuya-Smart-Combustible-Gas-Alarm-FIG-9
  2. LED indicator for Sensor status
  3. Instruction for voice prompt

Fault analysis and remedy

How to deal with an alarm
The alarm will keep sounding alarm while natural gas exceeds the alarm concentration, please follow the steps as below.

  1. Shut down all natural gas valves right away.
  2. Extinguish all fire sources, and avoid any actions that may incur fire or spark.
  3. It’s forbidden to turn on any household electrical appliances.
  4. Open the windows to ventilate the room.