hansgrohe 15701000 Metropol Ecostat S Shower Mixers Instruction Manual
- October 30, 2023
- hansgrohe
Table of Contents
- hansgrohe 15701000 Metropol Ecostat S Shower Mixers
- Product Information
- Product Usage Instructions
- Installation Instructions
- Technical Data
- Maintenance
- Symbol Description
- Safety Function
- Adjustment
- Dimensions
- Spare parts
- Operation
- Cleaning
- Test certificate
- Assembly
- TROUBLESHOOTING
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
hansgrohe 15701000 Metropol Ecostat S Shower Mixers
Product Information
The product is a shower system with different models such as Metropol, Metris, Metropol E, Metris E, Talis E, Metropol S, Metris S, Talis S Sportive, and Pura Vida. The product comes with user manuals and assembly instructions in different languages such as German, French, English, Italian, Spanish, Dutch, Danish, Polish, Chinese, Russian, Swedish, Lithuanian, Croatian, Turkish, Romanian, Greek, Slovenian, Estonian, Latvian, Serbian, Norwegian, Bulgarian, and Arabic. The shower system has a safety function and an anti- pollution function. The recommended operating pressure is 1.6MPa, and the rate of flow by 0.3 MPa is approximately 26 l/min.
Product Usage Instructions
-
Before installation or usage of the shower system, it is essential to read the user manual and assembly instructions carefully. Follow the safety notes mentioned in the user manual while installing or using the shower system. Wear gloves during installation to prevent crushing and cutting injuries. The shower system should only be used for bathing, hygienic, and body cleansing purposes. Children and people with physical, mental or sensory impairments must not use this shower system without proper supervision. Alcohol or drug-affected persons are prohibited from using this shower system.
-
The hot and cold supplies must be of equal pressure to avoid any issues while using the shower system. The fitting must be installed, flushed and tested after the valid norms. Do not use silicone-containing acetic acid. If the showerhead or spout drips, clean the filters mentioned in the user manual. In case of any other issues with the shower system such as low warm water temperature, dirty temperature control unit or thermostat or faulty spring or button, refer to the user manual and follow the instructions mentioned in it.
-
The shower system requires maintenance, and the user manual provides the necessary information about it. The symbol description, dimensions, and spare parts of the shower system are also mentioned in the user manual for reference.
-
Follow the assembly instructions mentioned in the user manual to install the shower system. The assembly instructions for different languages are available from page 2 to page 59 of the user manual. The user manual also includes technical data such as operating pressure, recommended operating pressure, hot water temperature, recommended hot water temperature, and anti-pollution function.
Safety Notes
- Gloves should be worn during installation to prevent crushing and cutting injuries.
- The shower system may only be used for bathing, hygienic, and body cleansing purposes.
- Children as well as adults with physical, mental, and/or sensory impairments must not use this shower system without proper supervision. Persons under the influence of alcohol or drugs are prohibited from using this shower system.
- The hot and cold supplies must be of equal pressure.
MODEL
Installation Instructions
The fitting must be installed, flushed, and tested after the valid norms!
Technical Data
- Operating pressure: max. 1 MPa
- Recommended operating pressure: 0,1 – 0,5MPa
- Test pressure: 1,6MPa (1 MPa = 10 bar = 147 PSI)
- Hot water temperature: max. 80°C
- Recommended hot water temp.: 65°C
- Rate of flow by 0,3 MPa: approx. 26 l/min anti-pollution function
Maintenance
(see page 64)
- To guarantee the smooth running of the thermostat, it is necessary from time to time to turn the thermostat from total hot to total cold.
- The mixer is equipped with nonreturn valves. The nonreturn valves must be checked regularly according to DIN EN 1717 in accordance with national or regional regulations (at least once a year). At this time, please also check the filter (A) situated on the MTC-thermopile-ment (94282000). After assembling the MTC-thermoelement, it is necessary to check the water temperature at the take-off point as described under the headline „adjustment“. Before the adjustment, please check, if the warm water supply is activated and the maximum temperature of the warm water is available at the take-off point.
Symbol Description
Do not use silicone-containing acetic acid!
Safety Function
The desired maximum temperature for example max. 42º C can be pre-set thanks to the safety function.
Adjustment
After the installation, the output temperature of the thermostat must be checked. A correction is necessary if the temperature measured at the output differs from the temperature set on the thermostat.
Dimensions
Spare parts
- XXX = Colors
- 000 chrome plated
- 090 chrome plated/gold plated
- 400 white/chrome plated
880 satin chrome
Operation
Cleaning
see the enclosed brochure.
Test certificate
Assembly
TROUBLESHOOTING
Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282
· Telefax +49 (0) 7836/511440
E-Mail: info@hansgrohe.com
Internet: www.hansgrohe.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>