HIB 33500 Turbo Fan Instruction Manual

October 30, 2023
HiB

33500 Turbo Fan
Instruction Manual

33500 Turbo Fan

Turbo Fans

| Turbo Chrome Non-Illuminated Art no.: 33600| | Turbo Chrome Illuminated
Cool White Art no.: 32300
Warm White Art no.: 33900
---|---|---|---
| Turbo White Non-Illuminated Art no.: 33500| | Turbo White Illuminated
Cool White Art no.: 32200
Warm White Art no.: 34000

HIB 33500 Turbo Fan - fig

All installations must comply with guidelines which are based on a zonal concept Fig.1. This concept must be followed to ensure the safe installation. These regulations apply to domestic installations only. Installations must be made in accordance with the current IEE wiring regulations and relevant building regulations.
Thank you for purchasing this HiB product. We recommend that all electrical bathroom products should only be fitted by a suitably qualified, Part P registered electrician.
Suitable for installation in zones: 2 & outside zones

Components

  • 1x Fascia.
  •  LED Driver – (for illuminated products only)
  • 1x High powered Inline Fan
  • 1x 3 metre flexible ducting
  • 1x White external fixed grille
  • 4x Galvanized steel hose clamps
  • 1x Screw and dowels pack
  • 1x Plastic Screwdriver
  • 1x Fitting instructions
  • 1x Foam strip.

HIB 33500 Turbo Fan - fig 1Electrical safety information- Ensure mains power supply is switched off before starting installation. Before drilling, ensure there are no hidden cables or pipes in the wall. The Turbo illuminated Inline Fans are supplied with a 5 Watt LED Lamp. DO NOT replace with any other lamp as this will invalidate any warranty. DO NOT exceed the stated wattage.
Please note:
Once the fan is powered this may turn on straight away. This is because the fan has a capacitor and holds an initial charge.

Mounting Fascia

  1. The ventilation should be ducted through the roof space, ducting to an external soffit under the eaves or grille in the slope of your roof. Ducting can only run between joists, not across them.
  2.  Mark the position of the fascia with a pencil in a suitable posistion on the ceiling, making sure that it is between joists.
  3.  Drill a 9mm hole through the ceiling along the edge of the pencil line. Now cut out the hole with a pad saw.
  4. Hold the fascia against the ceiling and mark the posistion of the fixing holes, fix the unit in place using suitable fixings- (not supplied)
  5.  Attach the flexible ducting with the metal hose clamps. Ensure the ducting has a smooth flow towards the motor body. Follow a simular procedure for the outside wall grille. Extra ducting may be used to extend the distance to the external grille but the performance will be reduced.

Mounting Fan Unit

Install the Turbo Inline fan within the loft or ceiling space, DO NOT COVER the motor or LED driver with loft insulation. The fan is only suitable for horizontal mounting on a wall or floor. Follow the visual aids below to mount the Fan unit. HIB 33500 Turbo Fan - Mounting Fan UnitDo not run the ducting over the joists, this will cause a build of condensation and reduce the extraction rate. Ensure the ducting is run between joists to create smooth airflow.

Electrical Connection

Ensure the mains power supply to which the fan is being connected to is turned off. This product is designed to be connected to an on/off switch outside the bathroom, or to a celing mounted pull cord switch.
Earth connection has been removed for illustration purposes onlyHIB 33500
Turbo Fan - Electrical ConnectionOnce the cover has been taken off then you can Install the fan wires into the terminals. The fan should be wired as follows:
N = Black or Blue
L = Brown
LT= Grey
See image left.
Earth connection has been removed for illustration purposes onlyHIB 33500
Turbo Fan - Electrical ConnectionAlternatively if you only have a two core cable, you can wire the fan up as follows:
N= Black or Blue L= Brown now you can loop from the L to the LT.
This does bypass the timer function. The fan will now only operate as an on/off fan.
See image left.
Bridge L, LT Only if permanent live is not available
Timer System
The timer circuit is under mains Voltage. Ensure mains power supply is switched off before making any adjustments.
The fan is operated by turning on the wall switch. When the switch is turned off the fan will continue to operate within the set perios of time. Adjustable between 2-30mins. This can be adjusted by turning the potentionmeter T clockwise to increase and anticlockwise to decrease the run time.
ONLY use the screwdriver provided to adjust the timer setting. Wiring diagram for lamp
Cool White and Warm White illuminated fans.HIB 33500 Turbo Fan - Electrical
Connection

Maintenance

Fan maintenance is to be performed only after the fan is disconnected from the mains power supply.
This includes periodic cleaning of the surface of dust and dirt.
All surfaces should be cleaned with a diluted detergent and a soft cloth. Avoid water dripping on the electric components. Wipe the surfaces dry after cleaning.
Aftercare service – In the unlikely event that this product should fail, please contact HiB customer services. The details are shown below.
WEEE compliance Must not be mixed with general household waste

T: +44 (0)20 8441 0352
F: +44 (0)20 8441 0219
E: sales@hib.co.ukhib.co.uk
Building 3, North London Business Park, Oakleigh Road South, New Southgate, London. N11 1GN
©HiB Copyright: No part of this document may be reprinted or duplicated without Hiba consent. All sizes and measurements are approximate, but we do try and make sure they are as accurate as possible. In the interest of continuous
product development, HiB reserves the right to alter specifications as necessary. E & OE.